Laboratorio Congiunto di Microneurografia e Microneurostimolazione
Pisa, 56127, Italy
Location status: Recruiting
Location contact
Calogero Maria Oddo, PhD
CONTACT
Calogero Maria Oddo, PhD
PRINCIPAL_INVESTIGATOR
NCT Number: NCT07691957
The goal of this experimental study is to investigate the somatosensory system through intraneural recording and stimulation of the median nerve in healthy volunteers and participants with upper-limb amputation. The main questions it aims to answer are:
* How does median nerve activity encode tactile perception during different types of mechanical tactile stimulation in healthy subjects? * How can tactile information be artificially encoded and restored through intraneural microstimulation in both healthy subjects and upper-limb amputee participants? How rich and functionally meaningful is the restored sensory information? * What are the neurophysiological mechanisms underlying tactile stimulus processing and the associated patterns of brain activation during tactile stimulation?
Participants will undergo median nerve recordings using microneurography during controlled mechanical tactile stimulation, as well as intraneural microstimulation with specific patterns to evoke near-natural tactile sensations. They will perform perceptual reporting tasks related to stimulus type, intensity, and localization, as well as psychophysical tests under different stimulation conditions. When possible, they will also undergo non-invasive recordings of brain activity using electroencephalography during sensory stimulation.
Interested in participating?
Request Info18 year–60 year
All sexes
Interventional
Not applicable
Pisa, 56127, Italy
Location status: Recruiting
Calogero Maria Oddo, PhD
CONTACT
Calogero Maria Oddo, PhD
PRINCIPAL_INVESTIGATOR
Participants will attend the laboratory where the entire research protocol will be conducted in a single visit lasting up to 4 hours.
Medical history and a physical examination will be collected. In participants with amputation, additional clinical information from previous neurological assessments will be reviewed (including medical records, nerve conduction velocity data, and ultrasound or MRI examinations required to verify inclusion/exclusion criteria). Psychometric tests will also be administered to assess language abilities, visuospatial skills, and general intelligence, ensuring that participants are able to understand and perform the experimental tasks. If inclusion and exclusion criteria are met, participants will undergo microneurography and/or intraneural microstimulation procedures. Participants will be seated comfortably, with the dominant arm (healthy volunteers) or the residual limb (participants with amputation) supported. A trained medical operator will identify the median nerve using external stimulation and/or ultrasound guidance to assist electrode insertion. The active electrode will be inserted into the nerve, while a reference electrode will be placed in the subcutaneous tissue a few centimeters away. Correct electrode placement will then be refined using intraneural stimulation. Once the nerve fascicle is reached, tactile stimulation of the hand will be used to identify single mechanoreceptive units. Final electrode placement will be confirmed by visual and auditory inspection of the neural signal. The median nerve activity must be clearly distinguishable from background activity when mechanical stimuli are applied to the skin. During electrode insertion, participants will be instructed to remain still until the procedure is completed. The intraneural microstimulation session, performed in both healthy volunteers and participants with upper-limb amputation, is preceded by peripheral neural recordings using microneurography during the presentation of tactile stimuli (e.g., Von Frey filaments). This step is used for accurate nerve localization and preliminary assessment of the receptors and their receptive fields. Once the neural target is identified, participants undergo intraneural stimulation involving the perception and recognition of artificially generated tactile stimuli. These stimuli are delivered via intraneural microstimulation and are derived from mechanoneural transduction, using a sensorized artificial finger interacting with different surfaces to encode surface-dependent tactile information. Participants will be asked to recognize different properties of the presented stimuli. During the tests, electroencephalographic (EEG) activity may be recorded using a 128-channel EEG system, synchronized with the onset of stimulation.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Healthy participants
Amputee participants
Exclusion criteria
Healthy participants
Amputee participants
Microneurography is a minimally invasive neurophysiological technique that allows direct recording of the electrical activity of single peripheral nerve fibers using specific microelectrodes inserted into the nerve.
Intraneural microstimulation is a minimally invasive neurophysiological technique in which small electrical currents are delivered through a microelectrode inserted into a peripheral nerve to selectively activate nerve fibers and evoke sensory perceptions.
Time frame: During the experimental protocol (up to 3 hours)
The proportion of experimental sessions in which a single mechanoreceptive afferent is successfully isolated and identified using MNG during controlled mechanical tactile stimulation, expressed as the percentage of successful recordings (%).
Time frame: During the experimental session (up to 3 hours)
The accuracy of mechanoreceptor type classification (e.g., SA1, SA2, RA, PC) based on MNG recordings during mechanical tactile stimulation, expressed as the percentage of correctly classified receptors (%).
Time frame: During the experimental session (up to 3 hours)
The mean firing rate (spikes/s) of mechanoreceptive afferents recorded by MNG during controlled mechanical tactile stimulation.
Time frame: During the experimental session (up to 3 hours)
The minimum stimulus intensity (expressed in grams of calibrated Von Frey Hairs) required to evoke a consistent neural response during mechanical tactile stimulation.
Time frame: During the experimental session (up to 3 hours)
The spatial extent of skin area (mm²) eliciting neural responses during mechanical tactile stimulation mapped via MNG.
Time frame: During the experimental protocol (up to 3 hours)
Participant-reported sensory percepts will be classified into predefined categories (e.g., pressure, vibration, tingling, tapping) and summarized as the frequency and percentage of each sensory class across stimulation conditions.
Time frame: During the experimental protocol (up to 3 hours)
Participants will rate the perceived intensity of each evoked sensation using a numerical rating scale from 0 (no sensation) to 10 (maximum imaginable intensity). Mean and standard deviation (or median and interquartile range) will be reported for each stimulation condition.
Time frame: During the experimental protocol (up to 3 hours)
Participants will indicate the anatomical location of each evoked sensation on a standardized hand map. Responses will be summarized as frequencies and percentages for each anatomical region.
Time frame: During the experimental session (up to 3 hours)
Discrimination performance will be assessed using a two-alternative forced-choice (2AFC) psychophysical paradigm during intraneural microstimulation. Performance will be quantified using the Elo rating system, a continuous score derived from pairwise stimulus comparisons. The Elo rating has no predefined minimum or maximum value. Higher Elo scores indicate greater discrimination performance.
Time frame: During the experimental protocol (up to 3 hours)
Event-related potentials (ERPs) elicited by intraneural microstimulation and recorded using 128-channel EEG will be quantified by peak amplitude (µV) of stimulus-locked cortical responses.
Time frame: During the experimental protocol (up to 3 hours)
Event-related potentials (ERPs) elicited by intraneural microstimulation and recorded using 128-channel EEG will be quantified by peak latency (ms) of stimulus-locked cortical responses.
Time frame: During the experimental session (up to 3 hours)
Changes in EEG spectral power recorded using 128-channel EEG during intraneural microstimulation expressed as spectral power (µV²) or percentage change from baseline (%)
Time frame: During the experimental session (up to 3 hours)
Machine learning-based classification of tactile stimulation conditions using EEG-derived features (classification accuracy %)
Contact information is provided by the study sponsor or research team.
Calogero Maria Oddo
CONTACT
Stefano Taddei
CONTACT
Azienda Ospedaliero, Universitaria Pisana
Other
Experimental Study to Investigate Sensory Control of the Upper Limb Through Microneurography and to Restore Near-natural Tactile Sensations Through Intraneural Microstimulation in Healthy and Amputee Subjects
Acronym: MICROAMP
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07677969
Back Pain, Daily Activities
Ankara, Turkey (Türkiye)
View Trial DetailsNCT05981664
Amniotic Band Syndrome, Congenital, Hereditary, and Neonatal Diseases and Abnormalities
Winnipeg, Manitoba, Canada
View Trial DetailsNCT07347561
Amputation, Prosthesis
Ankara, Keçiören, Turkey (Türkiye)
View Trial DetailsNCT06886295
Upper Limb Amputation
Bologna, Bo, Italy
View Trial Details