Skip to main content
OpenTrials
Enrolling by Invitation

NCT Number: NCT04003272

MDR - Comprehensive Reverse/Versa Dial Ti Glenosphere

The objective of this retrospective/prospective consecutives series PMCF study is to collect data confirming safety, performance and clinical benefits of the Comprehensive Versa-Dial Reverse Ti Glenosphere when used for primary total shoulder arthroplasty (implants and instrumentation) at a 1,2,3,5,7, and 10- year follow-up* to meet EU Medical Device and other Regulatory Requirements for Post-Market Surveillance. Because Comprehensive Versa-Dial Reverse Ti Glenospheres have only been on the market since 2009, a prospective aspect to the study will be utilized as well to collect long-term data.

*The most recent available data will be used. If any of the listed time points are not available, data will be used from last available time point and follow-up will move forward at the closest available time point.

Enrolling by Invitation

Interested in participating?

Request Info

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Norton Orthopaedic and Sports Medicine, Louisville, Kentucky, United States

Loading trial locations.

About this study

The objective of this retrospective/prospective consecutives series PMCF study is to collect data confirming safety, performance and clinical benefits of the Comprehensive Versa-Dial Reverse Ti Glenosphere when used for primary total shoulder arthroplasty (implants and instrumentation) at a 1,2,3,5,7, and 10- year follow-up* to meet EU Medical Device and other Regulatory Requirements for Post-Market Surveillance. Because Comprehensive Versa-Dial Reverse Ti Glenospheres have only been on the market since 2009, a prospective aspect to the study will be utilized as well to collect long-term data.

The primary objective is the assessment of safety by analyzing implant survivorship. This will be established by recording the incidence and frequency of revisions, complications and adverse events. Relation of the events to either implant or instrumentation should be specified.

The secondary objective is the assessment of performance and clinical benefits by recording patient-reported clinical outcomes measures (PROMs).

*The most recent available data will be used. If any of the listed time points are not available, data will be used from last available time point and follow-up will move forward at the closest available time point.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Biomet Comprehensive Reverse Shoulder products are indicated for use in patients whose shoulder joint has a grossly deficient rotator cuff with severe arthropathy and/or previously failed shoulder joint replacement with a grossly deficient rotator cuff. The patient must be anatomically and structurally suited to receive the implants and a functional deltoid muscle is necessary.

The Comprehensive Reverse Shoulder is indicated for primary, fracture, or revision total shoulder replacement for the relief of pain and significant disability due to gross rotator cuff deficiency.

Glenoid components with Hydroxyapatite (HA) coating applied over the porous coating are indicated only for uncemented biological fixation applications. The Glenoid Baseplate components are intended for cementless application with the addition of screw fixation.

Interlok™ finish humeral stems are intended for cemented use and the MacroBond™ coated humeral stems are intended for press-fit or cemented applications. Humeral components with porous coated surface coating are indicated for either cemented or uncemented biological fixation applications.

*** For the specific components, Titanium (Ti) Glenospheres are intended for patients with Cobalt Alloy material sensitivity.

Exclusion criteria

  • Absolute contraindications include infection, sepsis, and osteomyelitis.

Relative contraindications include:

  • Uncooperative patient or patient with neurologic disorders who is incapable or unwilling to follow directions.
  • Osteoporosis.
  • Metabolic disorders which may impair bone formation.
  • Osteomalacia.
  • Distant foci of infections which may spread to the implant site.
  • Rapid joint destruction, marked bone loss or bone resorption apparent on roentgenogram.
  • Patient is a prisoner.
  • Current alcohol or drug abuser.
  • If female, patient is known to be pregnant or breastfeeding.
  • Patient has a psychiatric illness or cognitive deficit that will not allow from proper informed consent.

Treatment and study plan

Comprehensive Reverse Versa-Dial Titanium Glenosphere

Device

Implant used for patients with allergy to typical device material metals to repair shoulder malfunction/disease.

Primary outcomes

  1. Product Safety assessed through the incidence and frequency of revisions, complications and adverse events

    Time frame: Out to 10 years

    The primary objective is the assessment of safety by analyzing implant survivorship. This will be established by recording the incidence and frequency of revisions, complications, and adverse events. Relation of the events to either implant or instrumentation should be specified.

Secondary outcomes

  1. Product Clinical Benefits and Performance evaluated through the Oxford Shoulder Scale OSS or Oxford Shoulder Questionnaire.

    Time frame: Out to10 years

    The secondary objective is the assessment of performance and clinical benefits by recording patient-reported clinical outcomes measures (PROMs) using the Oxford Shoulder Scale or Oxford Shoulder Questionnaire. The Scale ranges from 0-48 with 48 indicating a satisfactory joint function score. A score of 30-39 indicated moderate to mild arthritis, a score of 20-29 indicates moderate to severe arthritis and a score of 0-19 indicates severe arthritis.

  2. Product Clinical Benefits and Performance evaluated through the Patient Assessment Questionnaire

    Time frame: Out to 10 years

    The secondary objective is the assessment of performance and clinical benefits by recording patient-reported clinical outcomes measures (PROMs). This will be accomplished through the use of the Patient Assessment Questionnaire where adverse events and/or complications (yes or no- if yes, an Adverse Event Report would be completed), patient's activity level with regard to operative side (wholly inactive, mostly inactive, sometimes participates in mild activities, regularly participates in mild activities, sometimes participates in moderate activities, regularly participates in moderate activities, regularly participates in active events, regularly participates in very active events, sometimes participates in impact sports, regularly participates in impact sports, or not recorded), and the Reported Score if Individual Scores are not available. (This would be the reported score of the Oxford Shoulder Scale as described above in Outcome 2).

Sponsors and collaborators

Lead sponsor

Zimmer Biomet

Industry

Registry information

Official study title

Post-market Clinical Follow-up Study to Provide Safety, Performance and Clinical Benefits Data of the Comprehensive Versa-Dial Reverse Titanium (Ti) Glenosphere in Primary, Fracture and Revision Total Shoulder Arthroplasty

Important dates

Study start
2019
Primary completion
2034
Study completion
2035
First posted
Jul 1, 2019
Registry last updated
Feb 6, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.