Comprehensive Reverse Versa-Dial Titanium Glenosphere
DeviceImplant used for patients with allergy to typical device material metals to repair shoulder malfunction/disease.
NCT Number: NCT04003272
The objective of this retrospective/prospective consecutives series PMCF study is to collect data confirming safety, performance and clinical benefits of the Comprehensive Versa-Dial Reverse Ti Glenosphere when used for primary total shoulder arthroplasty (implants and instrumentation) at a 1,2,3,5,7, and 10- year follow-up* to meet EU Medical Device and other Regulatory Requirements for Post-Market Surveillance. Because Comprehensive Versa-Dial Reverse Ti Glenospheres have only been on the market since 2009, a prospective aspect to the study will be utilized as well to collect long-term data.
*The most recent available data will be used. If any of the listed time points are not available, data will be used from last available time point and follow-up will move forward at the closest available time point.
Interested in participating?
Request Info18 year and older
All sexes
Observational
Norton Orthopaedic and Sports Medicine, Louisville, Kentucky, United States
The objective of this retrospective/prospective consecutives series PMCF study is to collect data confirming safety, performance and clinical benefits of the Comprehensive Versa-Dial Reverse Ti Glenosphere when used for primary total shoulder arthroplasty (implants and instrumentation) at a 1,2,3,5,7, and 10- year follow-up* to meet EU Medical Device and other Regulatory Requirements for Post-Market Surveillance. Because Comprehensive Versa-Dial Reverse Ti Glenospheres have only been on the market since 2009, a prospective aspect to the study will be utilized as well to collect long-term data.
The primary objective is the assessment of safety by analyzing implant survivorship. This will be established by recording the incidence and frequency of revisions, complications and adverse events. Relation of the events to either implant or instrumentation should be specified.
The secondary objective is the assessment of performance and clinical benefits by recording patient-reported clinical outcomes measures (PROMs).
*The most recent available data will be used. If any of the listed time points are not available, data will be used from last available time point and follow-up will move forward at the closest available time point.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
The Comprehensive Reverse Shoulder is indicated for primary, fracture, or revision total shoulder replacement for the relief of pain and significant disability due to gross rotator cuff deficiency.
Glenoid components with Hydroxyapatite (HA) coating applied over the porous coating are indicated only for uncemented biological fixation applications. The Glenoid Baseplate components are intended for cementless application with the addition of screw fixation.
Interlok™ finish humeral stems are intended for cemented use and the MacroBond™ coated humeral stems are intended for press-fit or cemented applications. Humeral components with porous coated surface coating are indicated for either cemented or uncemented biological fixation applications.
*** For the specific components, Titanium (Ti) Glenospheres are intended for patients with Cobalt Alloy material sensitivity.
Exclusion criteria
Relative contraindications include:
Implant used for patients with allergy to typical device material metals to repair shoulder malfunction/disease.
Time frame: Out to 10 years
The primary objective is the assessment of safety by analyzing implant survivorship. This will be established by recording the incidence and frequency of revisions, complications, and adverse events. Relation of the events to either implant or instrumentation should be specified.
Time frame: Out to10 years
The secondary objective is the assessment of performance and clinical benefits by recording patient-reported clinical outcomes measures (PROMs) using the Oxford Shoulder Scale or Oxford Shoulder Questionnaire. The Scale ranges from 0-48 with 48 indicating a satisfactory joint function score. A score of 30-39 indicated moderate to mild arthritis, a score of 20-29 indicates moderate to severe arthritis and a score of 0-19 indicates severe arthritis.
Time frame: Out to 10 years
The secondary objective is the assessment of performance and clinical benefits by recording patient-reported clinical outcomes measures (PROMs). This will be accomplished through the use of the Patient Assessment Questionnaire where adverse events and/or complications (yes or no- if yes, an Adverse Event Report would be completed), patient's activity level with regard to operative side (wholly inactive, mostly inactive, sometimes participates in mild activities, regularly participates in mild activities, sometimes participates in moderate activities, regularly participates in moderate activities, regularly participates in active events, regularly participates in very active events, sometimes participates in impact sports, regularly participates in impact sports, or not recorded), and the Reported Score if Individual Scores are not available. (This would be the reported score of the Oxford Shoulder Scale as described above in Outcome 2).
Zimmer Biomet
Industry
Post-market Clinical Follow-up Study to Provide Safety, Performance and Clinical Benefits Data of the Comprehensive Versa-Dial Reverse Titanium (Ti) Glenosphere in Primary, Fracture and Revision Total Shoulder Arthroplasty
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06788717
Arthralgia, Fractures, Bone
Los Angeles, California, United States
View Trial DetailsNCT04003311
Arthralgia, Fractures, Bone
Boise, Idaho, United States
View Trial DetailsNCT07421245
Arthralgia, Fractures, Bone
Florham Park, New Jersey, United States
View Trial DetailsNCT04984291
Arthralgia, Fractures, Bone
Irvine, California, United States
View Trial Details