Anderson Orthopaedic Research Institute
Alexandria, Virginia, 22306, United States
NCT Number: NCT02508428
The purpose of the study is to determine whether crosslinked Marathon and standard Enduron polyethylene liners show differences in survivorship due to wear-related revisions at minimum 14-year follow-up and every 5 years after.
Looking for future studies?
Notify MeAll sexes
Interventional
Not applicable
Alexandria, Virginia, 22306, United States
Several institutions have reported very low wear rates with crosslinked polyethylene based on early and midterm clinical data. However, since revisions associated with osteolysis typically occur after 10-year follow-up, the greatest benefits of the reduced wear associated with crosslinked polyethylene are expected to be reflected in lower revision rates for wear-related complications at long-term follow-up.
While crosslinking has proven to substantially reduce polyethylene wear during the first decade in vivo, characterizing the long-term clinical performance of Marathon polyethylene remains important because crosslinking is accompanied by a reduction in the ultimate tensile strength, fatigue strength, and elongation to failure of ultra high molecular weight polyethylene. As a consequence, concerns have been expressed about the potential for the liner fracture, in vivo polyethylene oxidation or accelerated wear at long-term follow-up, the effects of femoral head roughening over time and the bioreactivity of crosslinked polyethylene debris particles. Ultimately, the best way to address these concerns is in the context of well-controlled, long-term clinical outcome studies. This study will evaluate outcome at a minimum of 14-years after surgery among the same group of patients whose outcome was previously reported at 10-year follow-up. As part of our efforts to follow patients throughout their lives to obtain long-term outcome data, we will continue to obtain routine follow-up every 5 years from the date of the patient's primary total hip arthroplasty for the duration of the patient's life or until revision of the polyethylene liner (estimated to be 25 years). Because we anticipate that the reduced incidence of wear and osteolysis will result in a lower incidence of revision surgery among the patients randomized to Marathon liners, implant revision for reasons related to wear will be our primary outcome measure at long-term follow-up.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
(from original study)
(from 10-year follow-up)
Exclusion criteria
(from original study)
(from 10-year follow-up)
Comparison of Marathon and Enduron polyethylene
Time frame: At 15-year follow-up and every 5 years after from the date of the patient's primary total hip arthroplasty for the duration of the patient's life or until revision of the polyethylene liner (estimated to be 25 years)
Kaplan-Meier survivorship was calculated using revision for wear/osteolysis as an endpoint.
Time frame: At minimum 14-year radiographic follow-up and every 5 years after from the date of the patient's primary total hip arthroplasty for the duration of the patient's life or until revision of the polyethylene liner (estimated to be 25 years)
A single reviewer, blinded to the type of polyethylene liner, evaluated femoral head penetration among all hips using serial anteroposterior pelvic radiographs. Two-dimensional head penetration was determined for each follow-up radiograph using Hip Suite Analysis version 8.0 with elliptical correction, a validated, computer-assisted technique. A linear wear rate was evaluated for each hip that had a minimum of three follow-up radiographs using a least-squares linear regression to calculate the slope of the best-fit line for the wear vector magnitude versus time in situ data. The slope from this regression represented the steady-state linear wear rate. The steady-state linear wear rate data from all hips in a group was used to compute a mean polyethylene wear value.
Time frame: At minimum 14-year radiographic follow-up and every 5 years after from the date of the patient's primary total hip arthroplasty for the duration of the patient's life or until revision of the polyethylene liner (estimated to be 25 years)
The incidence of clinically important osteolysis is based on the number of unrevised THAs (total hip arthroplasties) with at least 1.5 square centimeters of pelvic and/or femoral osteolysis. Osteolysis was defined as an area of localized loss of trabecular bone or cortical erosion that was not apparent on the pre-operative or immediate postoperative radiograph. To obtain lesion sizes, the defects were outlined on the anteroposterior pelvic and lateral radiographs. The area of the osteolysis was measured using Martell's Hip Analysis Suite software. Lesions were considered clinically important if the total area of osteolysis around a hip replacement was at least 1.5 square centimeters on either the AP or lateral view.
Time frame: At minimum 14-year follow-up and every 5 years after from the date of the patient's primary total hip arthroplasty for the duration of the patient's life or until revision of the polyethylene liner (estimated to be 25 years)
Patient satisfaction was quantified by asking participants to respond "yes" or "no" to the question, "Are you satisfied with the results of your hip operation?" Because some patients had both of their hips included in the study, these patients responded to the question, "Are you satisfied with the results of your hip operation?" for their right and left hips. As a consequence, the "Units Analyzed" is reported as hips while the "Number of Participants Analyzed" reflects the number of patients.
Time frame: At minimum 14-year follow-up and every 5 years after from the date of the patient's primary total hip arthroplasty for the duration of the patient's life or until revision of the polyethylene liner (estimated to be 25 years)
The Harris Hip Score measures outcome after hip replacement and is based on a scale from 0 (worst) to 100 (best). The score includes assessments of pain, functional ability, deformity and range of motion.
Anderson Orthopaedic Research Institute
Other
A Prospective, Randomized Clinical Study Comparing Marathon Polyethylene and Enduron Polyethylene Acetabular Liners Used in Total Hip Arthroplasty at Long-Term Follow-up
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT01121146
Arthritis, Bone Diseases
Alexandria, Virginia, United States
View Trial DetailsNCT02717559
Anterior Cruciate Ligament Injuries, Arthritis
View Trial DetailsNCT06718478
Arthritis, Connective Tissue Diseases
Tashkent, Uzbekistan
View Trial DetailsNCT05872633
Arthritis, Connective Tissue Diseases
View Trial Details