Lung Ultrasound as a Predictor for Successful Extubation in Preterm Infants

unit (NICU); however prolonged MV is known to be associated with serious complications including ventilator associated pneumonia, blood stream infections, bronchopulmonary dysplasia (BPD) and periventricular leukomalacia. At the same time, extubation failure increases morbidities and mortality. Hatch et al (2016) in their prospective study on 162 infants described adverse events in 40% of intubations and severe complications including need for CPR in 9%. Reintubations are frequently associated with hypoxemia, bradycardia, fluctuations in blood pressures and cerebral perfusion. Each intubation attempt increases the risk of traumatic injury to the upper airway, lung atelectasis and infections. Thus, there is a clear need to establish objective criteria that would help avoid extubation failure and the need for reintubation.

In recent years, a new imaging application has been introduced in neonatal practice-lung ultrasound (LUS), an accurate and reliable technique for the lung evaluation. LUS is safe, non-ionizing, easy to operate, and low-cost tool. The evaluation of lungs is performed in real-time, on the bedside and without anesthetic drugs. Lung aeration could be assessed in dynamics without extra radiation to the infant. Ultrasound findings combined with clinical information could be used for the prognosis of successful extubation in premature infants.

Completed

Looking for future studies?

Notify Me

Key information

Sex eligibility

All sexes

Study type

Observational

Primary location

Royal University Hospital

Saskatoon, Saskatchewan, Canada

About this study

Mechanical ventilation (MV) is a widely used therapeutic resource in neonatal intensive care unit (NICU); however prolonged MV is known to be associated with serious complications including ventilator associated pneumonia, blood stream infections, bronchopulmonary dysplasia (BPD) and periventricular leukomalacia. At the same time, extubation failure increases morbidities and mortality. Hatch et al (2016) in their prospective study on 162 infants described adverse events in 40% of intubations and severe complications including need for CPR in 9%. Reintubations are frequently associated with hypoxemia, bradycardia, fluctuations in blood pressures and cerebral perfusion. Each intubation attempt increases the risk of traumatic injury to the upper airway, lung atelectasis and infections. Thus, there is a clear need to establish objective criteria that would help avoid extubation failure and the need for reintubation.

Currently used criteria for extubation are subjective and based on clinical evaluation, chest radiograph findings, amount of ventilatory support and arterial blood gas (ABG) parameters. An accurate bedside test for extubation readiness in preterm infants born is even more important as this population is more susceptible to the complications of re-intubation. There are several studies that showed that reintubation after elective extubation is independently associated with increased likelihood of death and BPD in extremely preterm infants. The greatest risks are attributable to reintubation within the first 48 hours post-extubation.

Several studies have shown that a low lung volume and small chest radiograph lung area after extubation could predict extubation failure. Infants who have a low lung volume after extubation may have an unfavourable balance between respiratory muscle strength and respiratory load. Ideally, these infants should be identified before removal of the endotracheal tube.

In recent years, a new imaging application has been introduced in neonatal practice-lung ultrasound (LUS), an accurate and reliable technique for the lung evaluation. LUS is safe, non-ionizing, easy to operate, and low-cost tool. The evaluation of lungs is performed in real-time, on the bedside and without anesthetic drugs. Lung aeration could be assessed in dynamics without extra radiation to the infant. Ultrasound findings combined with clinical information could be used for the prognosis of successful extubation in premature infants.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Invasively ventilated infants born at less than 32 weeks of gestational age were included at the time of their first extubation

Exclusion criteria

  • infants born after 32 weeks of gestational age

Treatment and study plan

Lung Ultrasound (LUS)

Diagnostic Test

LUS performed 30 mins prior to and 120 minutes after planned extubation with a linear high frequency probe longitudinal approach was used in all three zones Repeated third scan will be done prior to re-intubation (if required) The ultrasound total execution cut-off time expected to be less than 5 minutes

Primary outcomes

  1. lung aeration before and after extubation by comparing LUS indexes

    Time frame: 30 minutes

  2. re-intubation within 12, 36 or 72 hours

    Time frame: 72 hours

Sponsors and collaborators

Lead sponsor

Royal University Hospital, Saskatoon

Other

Registry information

Acronym: LUSE

Important dates

Study start
2019
Primary completion
2020
Study completion
2020
First posted
Nov 29, 2022
Registry last updated
Nov 29, 2022