Aim. To investigate whether lung ultrasound can be used to detect extravascular lung water (EVLW) overload in the intensive care unit early after surgery.
Methods. This prospective study involved 60 patients without known cardiac or pulmonary diseases admitted to the intensive care unit at our hospital after elective abdominal or vascular surgery. The inferior vena cava collapsibility index (IVCcl), oxygen partial pressure (PaO2) and inspired oxygen pressure (FiO2) ratio (PaO2/FiO2), and appearance of B-lines ≤7 mm were determined upon admission to the intensive care unit and at 6, 12, and 24 h later. Fluid overload was defined as IVCcl ≤ 40% and the presence of B-lines ≤7 mm. Tissue oxygenation impairment was defined as a PaO2/FiO2 ratio < 200.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
After receiving general anesthesia, all patients received an endotracheal tube. After Co induction, anesthesia was maintained using a combination of inhalation anesthetic and intravenous drugs. Protective ventilation was combined with low flow. During surgery, all patients received Plasma Lyte 148 (pH 7.4; Viaflo, Baxter, Deerfield, IL, USA) at 6-8 ml/kg/h. Norepinephrine was administered at doses of 0.05-0.1 mcg/kg/min when needed to maintain mean arterial pressure over 60 mmHg. Packed red blood cells were used when hemoglobin concentration was ≤8.0 g/dl. At the end of anesthesia, participants were subjected to the recruitment maneuver. Patients older than 18 years admitted to intensive care unit after abdominal and vascular surgery with no cardiac or pulmonary diseases were included in the study.
.
After surgery, patients were admitted to the intensive care unit and given crystalloid Plasma Lyte at 1.5 ml/kg/h. At 24 h after surgery, all patients received the diuretic furosemide (20 mg).
Data on oxygen partial pressure and inspired oxygen pressure ratio (PaO2/FiO2), inferior vena cava collapsibility index (IVCcl) and occurrence of dense B-lines were monitored upon admission to the intensive care unit (baseline), as well as at 6, 12 and 24 h after admission. All measurements were done with the patients in supine position.
A decrease in PaO2/FiO2 ratio below 200 was taken to indicate a rise of extravascular lung water (EVLW) above 10 ml/kg (1-4); this cut-off indicates >20% shunting (5). IVCcl was measured based on changes in the diameter of the inferior vena cava during spontaneous breathing. IVCcl ≤40% was taken to indicate a rise in EVLW, since this cut-off reflects right arterial pressure of 10-15 mmHg (6). The appearance of "dense B-lines" on lung ultrasonography, defined as lines ≤7 mm apart, was also considered a sign of incipient increase in EVLW volume (7). Taking PaO2/FiO2 ratio as the reference method, we assessed the ability of dense B-lines, alone or in conjunction with IVCcl, to diagnose EVLW.
Statistical analysis was performed using SPSS 13 (Armonk, NY,USA). Independent-sample t tests were used to assess the significance of differences within groups for each set of measurements separately. The threshold of significance was p < 0.05. Possible correlation of PaO2/FiO2 ratio with occurrence of dense B-lines or with IVCcl ≤40% was assessed using the chi-squared test.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: Baseline- upon admission to the ICU, 6, 12 and 24 hours after admission.
The maximum and minimum IVC diameters (cm) were calculated using ultrasound. IVCcl was measured using formula [(maximum IVC diameter - minimum IVC diameter)/maximum IVC diameter] based on changes in the diameter of the inferior vena cava during spontaneous breathing. IVCcl ≤40% was taken to indicate a rise in EVLW, since this cut-off reflects right arterial pressure of 10-15 mmHg.
Time frame: Baseline- upon admission to the ICU, 6, 12 and 24 hours after admission.
PaO2/FiO2 ratio will be measured from the arterial blood. A decrease in P/F ratio below 200 was taken to indicate a rise of EVLW above 10 ml/kg; this cut-off indicates >20% shunting.
Time frame: Baseline- upon admission to the ICU , 6, 12 and 24 hours after admission.
The appearance of "dense B-lines" on lung ultrasonography, defined as lines ≤7 mm apart, was also considered a sign of incipient increase in EVLW volume
General Hospital Sveti Duh
Other
Lung Ultrasonography for Detecting Extravascular Lung Water Overload in Intensive Care Patients Early After Surgery: a Preliminary Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06984120
Extravascular Lung Water, Lung Diseases
Falun, Dalarna County, Sweden
View Trial DetailsNCT04660448
Acute Respiratory Distress Syndrome, Extravascular Lung Water
Oviedo, Principality of Asturias, Spain
View Trial DetailsNCT04659681
Extravascular Lung Water
Delhi, India
View Trial DetailsNCT03514706
Extravascular Lung Water
Cairo, Egypt
View Trial Details