CT scanner
DeviceRegular CT imaging of the abdomen and pelvis
Other names: Genesis TSX-350A CT scanner
NCT Number: NCT03425032
Computed tomography represents the mainstay for diagnosing various diseases in the whole body. Over the past decade, enormous efforts were undertaken by both CT manufacturers and radiologist to reduce the radiation dose to patients. Today, the dose is significantly lower that it was before the era of multislice CT and iterative reconstruction methods. The X-ray beam originating from the tube in a CT system contains a spectrum of different energies, whereby the "harder" beams with higher energy penetrate the patient better, and the "softer" beams will be absorbed through the patient's tissues. Recent research has been shown that the radiation dose can be further reduced by improved primary beam filtering in CT. This study is intended to compare the radiation dose in clinically indicated, routine CT examination while maintaining a diagnostic image quality, on a new CT system with modified primary beam filtering.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
At the Joint Department of Medical Imaging (JDMI), the investigators periodically adjust the radiation dose and modify the clinical imaging protocols in order to continuously optimize image quality in CT. The investigators have formalized the process of radiation dose adjustments by implementing a CT dose committee that meets on a monthly basis and reviews imaging protocols (SOP). The committee includes radiologists, technologists, vendor representative (if needed), managers and the radiation protection officer. Part of the review is the investigator's in-house developed Coral image quality review program as well as the clinically used radiation dose monitoring software (Radiometric).
Part of the evaluation study of the new CT system is to monitor 520 patients who will undergo a clinically indicated CT scan on the new system. Identical to standard-of-care (SOC) quality insurance, the investigators will use the existing monitoring software (Radiometric, JDMI) in order to capture the data in the existing database. The investigators will also capture quality data through the existing CT image quality feedback tool. After installation of the new CT system, the investigators will maintain the radiation dose as currently applied in the standard JDMI wide imaging protocols and examine 20 patients on the new system; radiation dose and image quality feedback will be recorded in the identical fashion to standard operating procedures (CT image quality and radiation dose committee). Subsequently, the investigators will drop the dose by approx. 10% for each scanning protocol and scan the subsequent 250 patients while concurrently analyzing the impact on the collective dose to the patient population. Based on the expected increase in image noise, the investigators will calculate the possible additional dose reduction in percent and modify all protocols accordingly for the subsequent 250 patients. This step-down approach ensures that no CT scan will be performed with too little dose, and that all CT scans remain diagnostic.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Regular CT imaging of the abdomen and pelvis
Other names: Genesis TSX-350A CT scanner
Time frame: Through study completion, an average of 1 year
Mean radiation dose (DLP), comparison to existing data (Radimetrics database)
University Health Network, Toronto
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06769594
Computed Tomography
Madison, Wisconsin, United States
View Trial DetailsNCT06280638
Computed Tomography, Coronary Physiology
Beijing, Beijing Municipality, China
View Trial DetailsNCT06125678
Computed Tomography, Crohn Disease
Hyderabad, Telangana, India
View Trial DetailsNCT06845462
Atrophy, Body Composition
Shanghai, Shanghai Municipality, China
View Trial Details