Ajou university school of medicine
Suwon, Gyeonggi-do, 16377, South Korea
NCT Number: NCT03645174
In difficult airway situation, fiberoptic-guided endotracheal intubation through laryngeal mask airway(LMA) is one of option. Aintree catheter is a device to help change LMA to endotracheal tube, but it needs complex and multiple process. Long endotracheal tube can solve this problem of Aintree catheter. The purpose of this study is proving the efficacy of long endotracheal tube compared to Aintree cathter in fiberoptic-guided intubation through LMA.
Looking for future studies?
Notify Me20 year–40 year
All sexes
Interventional
Not applicable
Suwon, Gyeonggi-do, 16377, South Korea
In difficult aiway situation, fiberoptic-guided endotracheal intubation through laryngeal mask airway(LMA) is one of option according to Difficult intubation guidelines. First, insert LMA and insert fiberoptic through LMA. Second, insert endotracheal tube using fiberoptic as a guide. This process has several problem. Removal of LMA is impossible, so there is a risk of dislodging of endotracheal tube.
Aintree catheter is developed to this problem. Insert Aintree catheter through LMA using fiberoptic, and remove LMA, finally insert endotracheal tube throug Aintree catheter. But the problem of this method is that the whole process is complex and takes long time. And there is a risk of impeding of endotracheal tube at glottis level because the difference of diameters between endotracheal tube and aintree catheter.
Long endotracheal tube could solve the problems mentioned above. Through LMA, insert endotracheal tube using fiberoptic as a guide. Tube is long enough to remove LMA without a risk of dislodging. And after removal of LMA, tube can be cut for optimizing length.
So the purpose of this study is comparing the efficacy of Aintree catheter method and Long tube method in manikin.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Fiberoptic-guided intubation through LMA, using long tube
Fiberoptic-guided intubation through LMA, using Aintree catheter
Time frame: 3 minutes
from entry of fiberoptic at LMA to Ambu bagging
Time frame: 5 minutes
Failure is esophageal intubation or disloding of endotracheal tube in any process
Time frame: 5 minutes
Subjective score using numeric rating scale (1; extremely easy - 10; extremely difficult)
Ajou University School of Medicine
Other
Fiberoptic-guided Endotracheal Intubation Through Laryngeal Mask Airway in Manikin; Long Endotracheal Tube vs. Aintree Intubating Catheter
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04716218
Intubation;Difficult
Seoul, South Korea
View Trial DetailsNCT03779984
Intubation;Difficult
Dallas, Texas, United States
View Trial DetailsNCT06448377
Airway Management, Intubation;Difficult
Kocaeli, Izmıt, Turkey (Türkiye)
View Trial DetailsNCT04457453
Intubation;Difficult
Suwon, Gyeong-gi Do, South Korea
View Trial Details