Recep Tayyip Erdogan University Oral an Mazillofacial Surgery
Rize, Merkez, 53000, Turkey (Türkiye)
NCT Number: NCT06148012
Purpose: The aim of this study was to investigate the influence of surface characteristics and geometric design on marginal bone loss and bone quality in dental implants.
Materials and Methods: A total of 378 implants from 114 patients were evaluated in this study using panoramic and periapical radiographs. Implants were categorized into 19 subgroups according to the jaw where they were placed, length, diameter, surface preparation, type of prosthetic superstructure, and neck design. Radiological evaluations were conducted based on radiographs obtained at the time of implant placement and 3 months after prosthetic loading. After obtaining measurements of marginal bone loss and fractal analysis data, the significance of differences between groups was statistically evaluated.
Looking for future studies?
Notify Me18 year and older
Male
Interventional
Not applicable
Rize, Merkez, 53000, Turkey (Türkiye)
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Digital panoramic radiographs taken during the patients' treatment periods (T0, T1) were used in the study. Measurements of marginal bone levels on radiographs were performed using the "Image J" software. The distance between the most coronal part of the implant neck and the most apical part of the defect caused by marginal bone loss was measured.
Fractal analysis (FA) was conducted on panoramic radiographs (OPG) with a size of 2952x1435 pixels and a depth of 32 bits. FA on these radiographs at T0 and T1 times was performed using the box counting method determined by White and Rudolp with the ImageJ program(23).
Time frame: 180 days
Number of Participants: 114 Number of Dental Implants: 378
Implants will be categorized into 19 subgroups according to the jaw where they were placed, length, diameter, surface preparation, type of prosthetic superstructure, and neck design. Radiological evaluations will be conducted based on radiographs obtained at the time of implant placement and 3 months after prosthetic loading.
The distance between the most coronal part of the implant neck and the most apical part of the defect caused by marginal bone loss(millimeters) will be measured. The magnification ratio will be calculated by comparing the previously recorded implant length with the length measured on the software, allowing the determination of the actual value of MBL.
Time frame: 180 days
A total of 378 implants from 114 patients will be evaluated in this study using panoramic and periapical radiographs. Implants will be categorized into 19 subgroups according to the jaw where they were placed, length, diameter, surface preparation, type of prosthetic superstructure, and neck design. Radiological evaluations will be conducted based on radiographs obtained at the time of implant placement and 3 months after prosthetic loading. And measurement pre op post op fractal values
Recep Tayyip Erdogan University
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05024760
Dental Implant Failed, Implant Infection
Tacoma, Washington, United States
View Trial DetailsNCT04576052
Implant Infection
Münster, North Rhine-Westphalia, Germany
View Trial DetailsNCT03343288
Implant Infection, Implant Site Infection
Eskişehir, Turkey (Türkiye)
View Trial DetailsNCT04120181
Cochlear Hearing Loss, Ear Diseases
View Trial Details