Skip to main content
OpenTrials
Completed

NCT Number: NCT02089542

Intra-operative Infra-red Fluorescent Imaging in Thyroid and Parathyroid Surgery

Reliable identification of parathyroid glands is critical to the success of thyroid and parathyroid surgery. In thyroid surgery, inadvertent injury to parathyroid glands may cause temporary or permanent hypoparathyroidism (low calcium levels needing long term treatment). In parathyroid surgery, early identification of normal and/or enlarged parathyroid glands helps in deciding on the extent of surgery and increases the chances of postoperative normal calcium levels.

Methylene Blue (Methylthioninium chloride, MB) is a dye that when given intravenously in high doses, is taken up differently by thyroid and parathyroid tissue. It is currently used during parathyroid surgery by some surgeons to help identify enlarged parathyroid glands by visual examination alone. Such visual examination is unhelpful in the identification of 'normal' parathyroid tissue. MB exhibits fluorescent properties in the near-infrared range (light just beyond the visible spectrum). This can be picked up by an appropriate imaging system. This has potential to identify and differentiate between 'normal' parathyroid, 'abnormal' parathyroid and thyroid tissue during surgery.

The investigators have established the feasibility of the intra-operative use of a near infra-red fluorescent imaging device called Fluobeam® and demonstrated the ability of this device to pick up near infra-red fluorescence from human tissue after administration of intravenous MB. Animal experiments have shown that doses as low as 0.1mg/kg of MB given intravenously enable fluorescent visualisation of thyroid and parathyroid glands.

This study will aim to optimise the dose and timing of administration of MB in human thyroid and parathyroid surgery and to develop a protocol which would then subsequently be assessed for effectiveness in a multi-centred randomized controlled setting.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 1 / Phase 2

Primary location

Department of General Surgery

Sheffield, South Yorkshire, S10 2JF, United Kingdom

About this study

Around 13,000 thyroid and parathyroid operations are performed per year in England for both benign and malignant disease. Reliable identification of parathyroid glands is critical to the success of thyroid and parathyroid surgery. In thyroid surgery, inadvertent injury to parathyroid glands may cause temporary or permanent hypoparathyroidism (low calcium levels needing long term treatment); the latter is associated with significant long term problems. In parathyroid surgery, early identification of normal and/or enlarged parathyroid glands helps in deciding on the extent of surgery and increases the chances of postoperative normal calcium levels.

Methylene Blue (Methylthioninium chloride, MB) is a dye that when given intravenously in high doses, is taken up differently by thyroid and parathyroid tissue. It is currently used during parathyroid surgery by some surgeons to help identify enlarged parathyroid glands by visual examination alone. At these doses, there is a risk of adverse effects from administration of MB. Such visual examination is unhelpful in the identification of 'normal' parathyroid tissue. MB is not currently used in surgery for thyroid pathologies. MB exhibits fluorescent properties in the near-infrared range (light just beyond the visible spectrum). This can be picked up by an appropriate imaging system. This has potential to identify and differentiate between 'normal' parathyroid, 'abnormal' parathyroid and thyroid tissue during surgery.

The investigators have established the feasibility of the intra-operative use of a near infra-red fluorescent imaging device called Fluobeam® and demonstrated the ability of this device to pick up near infra-red fluorescence from human tissue after administration of intravenous MB. Animal experiments have shown that doses as low as 0.1mg/kg of MB given intravenously enable fluorescent visualisation of thyroid and parathyroid glands.

This study will aim to optimise the dose and timing of administration of MB in human thyroid and parathyroid surgery and to develop a protocol which would then subsequently be assessed for effectiveness in a multi-centred randomized controlled setting.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

-All patients undergoing either a total thyroidectomy or bilateral neck exploration for PHPT in Sheffield Teaching Hospitals NHS Foundation Trust

Exclusion criteria

  • Patients undergoing re-do procedures
  • Patients unable to understand spoken and written English
  • Patients unable to give adequate informed consent
  • Patients with a history of intolerance or sensitivity to MB
  • Patients with known G6PD deficiency
  • Patients on serotonin reuptake inhibitors
  • Patients undergoing surgery for thyroglossal cyst and
  • Patients undergoing thoracic exploration; either alone or in combination with a neck exploration

Treatment and study plan

MB and fluorescent imaging

Other

Single arm study for the development of a protocol stipulating the optimum dose and time to peak near infra-red fluorescence from intraoperative injection of low dose Methylthioninium chloride

Other names: Methylthioninium chloride, Fluobeam 700 near infra-red imaging device

Primary outcomes

  1. Optimum dose of Methylene Blue

    Time frame: 20 minutes

    Determine optimum dose of Methylene Blue that will enable fluorescence to be detected from the soft tissue structures in the neck

Secondary outcomes

  1. Time to peak fluorescence

    Time frame: 20 minutes

    Time to peak fluorescence at varying doses of Methylene Blue will be assessed during the observation period, which will be a maximum of twenty minutes.

Other outcomes

  1. Postoperative calcium status

    Time frame: up to 12 weeks of surgery

  2. Serious adverse event

    Time frame: up to 30 days after surgery

    This will include any one of the following:

    • Death
    • A life-threatening adverse event
    • Inpatient hospitalisation or prolongation of existing hospitalisation
    • A disability / incapacity
    • A congenital anomaly in the offspring of a participant The reporting period for Serious Adverse Events will be from the time of induction of anaesthetic until 30 days after the day of surgery. Important medical events that may not result in death, be life-threatening, or require hospitalisation may be considered a serious adverse event when, based upon appropriate medical judgment, they may jeopardize the patient or participant and may require medical or surgical intervention to prevent one of the outcomes listed in this definition. All adverse events will be assessed for seriousness, expectedness and causality.

Sponsors and collaborators

Lead sponsor

Sheffield Teaching Hospitals NHS Foundation Trust

Other

Registry information

Official study title

Development of a Clinical Protocol to Use Intra-operative Near Infra-red Fluorescent Imaging in Thyroid and Parathyroid Surgery

Important dates

Study start
2014
Primary completion
2016
Study completion
2016
First posted
Mar 17, 2014
Registry last updated
Nov 2, 2016

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.