University Clinical Center Tuzla
Tuzla, 75000, Bosnia and Herzegovina
NCT Number: NCT02941640
During laparoscopic appendectomy, the base of the appendix is usually secured by an endoloop ligature or the stapler. Non-absorbable plastic hem-o-lok clip was shown as an alternative technique with which laparoscopic appendectomy was done faster and cheaper than the standard techniques. However, biocompatibility of different materials udes in securing the base of appendix is different. It was observed that stapler's clips made by titanium caused the mildest inflammatory reaction and creation of adhesions. Disadvantages of stapler's are their high price.
Titanium clips made for the use in laparoscopic appendectomy are safe and effective option in securing the appendicular stump in laparoscopic appendectomy. They have potential advantages over stapler, because they have the same bio compatibility, and their price is lower.
Looking for future studies?
Notify Me18 year–80 year
All sexes
Interventional
Not applicable
Tuzla, 75000, Bosnia and Herzegovina
Prospective study was conducted in the period from 02. October 2016 to 30. December 2016. The patients were randomly divided into four groups; in the first group, the base of the appendix was secured using one endoloop ligature, in the second group using the 45-mm stapler, in third group using only one non-absorbable Hem-o-lok clip and in fourth group using titanium DS clip.
Patients were assessed for eligibility at the emergency station by the surgeon on-call once the diagnosis of acute appendicitis was established. A dedicated study nurse assigned randomly to Endoloop (E group) or Stapler (S group), or Hem-o-lock (H group), or DS clip (DS group) by picking out of a box and opening a sealed opaque randomization envelope in operating theatre. The details of the allocated treatments (''E'' or ''S'', or (''H'' or (''Ds'' ) were given on cards contained in sealed opaque envelopes. All sealed opaque envelopes were previously prepared with a 1 : 1 ratio, well shuffled, and put into a box by the dedicated study nurse. No blinding was performed.
Data collected included age, gender, surgery time, time of hem-o-lok clip application, hospital stay, costs associated with these and intra- and post-operative complications.
Technique
The patient was placed in supine position, combined with Trendelenburg position and left lateral position (10º - 15º, incline towards the surgeon). The surgeon used the French position (between legs of patient) and an assistant stood on the left side, and monitor was on the right side of the patient. The bladder was decompressed with the Foley catheter to avoid an injury during insertion of the supra-pubic ports. Pneumoperitoneum was established with the Veress needle through the umbilicus and then an endoscope was introduced. Under direct vision, one 12 mm trocar was inserted in suprapubic region, a little to the left, and 5 mm trocar in the right lower quadrant, to the level of the first 12 mm port, in order to acquire triangulation. After that the abdominal cavity was inspected.
When the decision was made to perform appendectomy, mesoappendix was mobilized and dissected using an harmonic scalpel (Ethicon, Endosurgery, Cincinnati, OH). In the first group, the base of the appendix was secured using one endoloop, and on the distal part which would be removed, another endoloop was used. In the second group, the appendix was secured by a 45 mm stapler (thick charge) (Ethicon, Endosurgery, Cincinnati, OH). In the third group, one hem-o-lok clip, size XL (Hem-o-lock, Weck Closure Systems, Research Triangle Park, NC, USA) was placed on the base the appendix by a special applier for the hem-o-lok clip, and on the distal part which would be removed, another clip was used. In the fourth group, one titanium DS clip (Aesculap AG, Tuttlingen, Germany) was placed on the base of appendix by endoscopic clip applier (12 mm) and on the distal part which would be removed, another DS clip was used.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The securing the base of appendix by endoloop.
Other names: Endoloop
The securing the base of appendix by Stapler.
Other names: Stapler
The securing the base of appendix by Hem-o-lok clip.
Other names: Hem-o-lok clip
The securing the base of appendix by DS clip.
Other names: DS clip
Time frame: 30 days
Overall morbidity following the securing of the base of the appendix, defined as any adverse event occurring from the time of securing the base of the appendix until the 30th day.
Time frame: 120 min.
Complications that appear during operative procedure
Time frame: 30 days
Complications that appear after operative procedure
Time frame: 120 min.
Time of operative procedure
Time frame: 120 min
Time of application of endoloop, stapler, Hem-o-lok and DS clip measured from introducing of instruments to cutting the base of appendix
Time frame: 30 days
Length of hospitalization
University Clinical Center Tuzla
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05002829
Appendicitis, Cecal Diseases
Denver, Colorado, United States
View Trial DetailsNCT05887414
Appendicitis, Cecal Diseases
Baldwin Park, California, United States
View Trial DetailsNCT05209061
Appendicitis, Cecal Diseases
Copenhagen, Denmark
View Trial DetailsNCT04986397
Appendicitis, Cecal Diseases
Boston, Massachusetts, United States
View Trial Details