Inertial Sensors Used to Learn Manipulation

* Background Context: no studies have been identified to analyse the effect of real time feedback (using inertial sensors) on physiotherapy students learning the art of posterior-anterior thoracic manipulation (PATM). * Purpose: to study the effect caused by real-time feedback on the learning process for PATM, comparing two undergraduate physiotherapy student groups. Hypothesis: significant differences will exist in the execution parameters of manipulation among students receiving real-time feedback versus those who do not. * Study Design/Setting: longitudinal, pre-post intervention. * Patient Sample: Sixty-one undergraduate physiotherapy students were divided randomly into two groups, G1 (n = 31) (group without feedback in real time) and G2 (n = 30) (group with real-time feedback). * Outcome Measures: time, displacement and velocity and improvement (only between groups) to reach maximum peak, to reach minimum peak from maximum peak, total manipulation time. * Methods: two groups of physiotherapy students learned PATM, one using a traditional method and the other using real-time feedback (inertial sensor). Measures were obtained pre- and post-intervention. Intragroup pre- and post-intervention and intergroup post-intervention scores were calculated. An analysis of the measures' stability was developed through an ICC (1,2). * Results: the values of ICC ranged from 0.881 to 0.997. Statistically significant differences were found in all variables analysed (intra- and inter-group) in favour of G2. * Conclusions: the learning process for posterior-anterior thoracic manipulation is facilitated when the student receives real-time feedback.

Completed

Looking for future studies?

Notify Me

Key information

Conditions

Age range

18 year–65 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Participants did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

Exclusion criteria

  • Refusal to participate in the study

Treatment and study plan

Real Time Feedback

Device

Before beginning practice, one of the teachers performed the manipulation and explained the graph parameters as real-time feedback to consider when interpreting the graph, leaving the graphic as the benchmark execution

Traditional Learning Method

Device

Two expert teachers in manual therapy provided indications and corrections to the group with a teacher - student ratio of 1:8.

Primary outcomes

  1. Change from displacement maximum peak (seconds)

    Time frame: baseline; post-education; 24 weeks follow up

    An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

  2. Change from Time to reach maximum peak (seconds)

    Time frame: baseline; post-education; 24 weeks follow up

    An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

  3. Change from Displacement between maximum and minimum peak (milimitres)

    Time frame: baseline; post-education; 24 weeks follow up

    An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

  4. Change from Total manipulation time (seconds)

    Time frame: baseline; post-education; 24 weeks follow up

    An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

  5. Change from Velocity to reach maximum peak (degrees per second)

    Time frame: baseline; post-education; 24 weeks follow up

    An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

  6. Change from Time to reach peak minimum from maximum peak (seconds)

    Time frame: baseline; post-education; 24 weeks follow up

    An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

  7. Change from Velocity to reach minimum peak from maximum peak (degress/second)

    Time frame: baseline; post-education; 24 weeks follow up

    An instrumented manikin (Resusci Anne Full Body with signal box, Laerdal Medical AS) joined an inertial sensor (Inertial Cube (Intersense Inc, USA)) was used to register the physical parameters during execution of the PATM. The inertial sensor was placed in the middle of the thoracic spine, placing hands immediately below the sensor. The manikin has a ribcage with a deformation capacity similar to that of a human thorax. This option was chosen to minimize the power variation when comparing differences in parameters between different groups of students. The inclusion criteria used were that they did not have any training in manual therapy techniques, especially those involving a high velocity, low amplitude execution.

Sponsors and collaborators

Lead sponsor

University of Malaga

Other

Registry information

Official study title

EFFECT OF REAL-TIME FEEDBACK THROUGH INERTIAL SENSORS IN LEARNING POSTEROANTERIOR THORACIC MANIPULATION

Important dates

Study start
2012
Primary completion
2012
Study completion
2012
First posted
Jul 30, 2013
Registry last updated
Dec 4, 2014

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.