University of Missouri
Columbia, Missouri, 65212, United States
NCT Number: NCT00829621
People who have been scheduled for surgery using Bone Morphogenic Protein (called BMP-2) and an incisional vacuum assisted closure device (called IVAC) will be asked to join this study.
The purpose of this study is to see if using the IVAC device removes BMP-2 from the wound. BMP-2 is a protein used by the body to increase bone healing, decrease the need for additional surgery, and reduce infection rates.
The IVAC is a device that involves a foam dressing secured with an adhesive drape to make an airtight seal over a surgical incision. Tubing runs from the foam dressing to a device that uses gentle suction to drain fluid out (like a vacuum). The IVAC stays on for 48-72 hours depending on amount of drainage. The IVAC by itself helps reduce wound swelling and complications (such as infection).
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Columbia, Missouri, 65212, United States
It is hypothesized that the negative pressure associated with an IVAC is not sufficient to remove BMP-2 from a surgical wound.
BMP-2 is commonly used in open tibia fractures at the time of definitive wound closure, and these wounds are prone to increased swelling and wound complications. The recent observation that IVAC decreases wound edema and increases oxygenation has led to their use in such cases. Used in conjunction, it is entirely possible that the negative pressure exerted by the IVAC can remove BMP-2 from surgical site and therefore decreases the effectiveness of BMP-2. We seek to determine if BMP-2 is present in effluent from the IVAC. If in this study the hypothesis is found to be wrong, and BMP-2 is found within the IVAC effluent, we are prepared to proceed with a follow-up study to quantify the BMP-2 removed by the IVAC.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Incisional Vacuum Assisted Closure (IVAC) Device, set to 75 mmHg suction throughout the duration of the IVAC use.
Incisional Vacuum Assisted Closure (IVAC) Device, set to 125 mmHg suction throughout the duration of the IVAC use.
Time frame: 12-hours, 24-hours, 36-hours, and 48-hours after IVAC application
Presence of BMP-2 in effluent collected in IVAC canister
University of Missouri-Columbia
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06130397
Bone Fracture, Dislocation
Oxford, Oxfordshire, United Kingdom
View Trial DetailsNCT05260463
Fibula Fractures, Fracture of Fibula
Regensburg, Bavaria, Germany
View Trial DetailsNCT04274530
Acute Pain, Chronic Pain
Indianapolis, Indiana, United States
View Trial DetailsNCT02957240
Arm Injuries, Autonomic Nervous System Diseases
Minneapolis, Minnesota, United States
View Trial Details