Skip to main content
OpenTrials
Completed

NCT Number: NCT05246709

Impact of Cyanoacrylate Glue on PICC Line Dressing Care

This study will evaluate whether applying micro drops of cyanoacrylate glue to the participant's peripherally inserted central catheter (PICC) insertion site prior to covering the area of PICC line with a transparent film dressing will make the PICC dressing last longer and prevent an occurrence of PICC line moving out of its original placement. The investigators aims to evaluate whether 1) using the cyanoacrylate glue will lengthen the time to first dressing change; and 2) participants in the experimental arm (glue used) will have fewer dressing changes per week compared to the control arm (standard care) during admission.

Completed

Looking for future studies?

Notify Me

Key information

Age range

1 day–6 month

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

NewYork-Presbyterian Morgan Stanley Children's Hospital at CUIMC

New York, 10032, United States

About this study

The neonatal population poses a unique challenge due to the small surface area of PICC sites, underdeveloped skin layer, and inability to contain the child's movements during a dressing change.

PICC line migration is the most common complication of PICC line maintenance in the neonatal intensive care unit (NICU). Previous studies have found that the PICC migration/dislodgment mostly occurs during PICC dressing changes among the neonatal population.

Recent published studies demonstrated that medical tissue adherence glue, Cyanoacrylate, significantly reduces the incidences of catheter migration and insertion site bleeding of PICC lines in all age of patients including premature infants.

The proposed study is a randomized control study with aimed data collection of 60 participants; of the 60 participants, 50 participants' data are to be used for statistical analysis and additional 10 participants to account for withdrawals.

The participants will be randomly assigned to one of two groups: one (the control group) receiving our standard PICC dressing method and the other (the study group) receiving cyanoacrylate glue at the PICC insertion sites prior to applying a standard transparent film dressing over the PICC sites.

The control group will reflect standard practice of PICC insertion and dressings using a standard transparent polyurethane film dressing, 3M TEGADERM Film.

The study group will reflect the application of a few drops of cyanoacrylate glue, SecurePortIVTM by Adhezion Biomedical® at the insertion sites prior to dressing a PICC line area with a standard transparent polyurethane film dressing.

The aim for this study is to investigate whether the application of cyanoacrylate glue at the insertion sites prior to dressing a PICC line area with a standard dressing will increase the longevity of the PICC line dressing and reduce the incidences of PICC line migration.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • All patients admitted to the 9 North intensive coronary care unit (ICCU) at NewYork-Presbyterian Morgan Stanley Children's Hospital greater than 35 weeks of corrected gestational age who have a PICC line placed by a NICU provider.

Exclusion criteria

  • Any patient with a PICC line in situ from an outside hospital.
  • Any patient with a PICC line placed by an outside department, namely the interventional radiology department.
  • Any patient with a PICC line that is silicon material catheter, such as Vygon Epicutaneo-Cava catheter because of limited accuracy of measuring a movement of the catheter migration after 25 centimeter mark due to absence of a centimeter mark on the catheter.

Treatment and study plan

Cyanoacrylate glue

Device

Adhesive to be applied on the PICC line site prior to usual standard film dressing over the site, such as SecurePortIV® Catheter Securement Adhesive by Adhezion Biomedical® Cyanoacrylate adhesive that is FDA-approved for securement of vascular access devices.

Securement method that provides microbial protection by sealing the insertion site.

Other names: SecurePortIV® Catheter Securement Adhesive

Standard transparent film dressing

Device

A standard transparent polyurethane film dressing, such as 3M TEGADERM Film, for dressing the PICC line area.

Primary outcomes

  1. Duration of Longevity of PICC Line Dressing

    Time frame: Up to 7 days

    Duration of longevity defined as the number of days the PICC line dressing lasts from the scheduled dressing change.

Secondary outcomes

  1. Number of PICC Line Migrations

    Time frame: Until PICC line removal (approximately 12 weeks)

    A PICC line migration is defined as a change in the length of catheter extruding from the insertion site - a catheter migration of more than 0.25 cm will be counted. The reported values represent the total number of PICC line migrations observed across all participants.

Sponsors and collaborators

Lead sponsor

Columbia University

Other

Registry information

Official study title

Randomized Control Study to Evaluate Impact of the Use of Cyanoacrylate Glue on PICC Line Dressing Care in the Infant Cardiac Care Unit at Children's Hospital of New York

Important dates

Study start
2022
Primary completion
2022
Study completion
2022
First posted
Feb 18, 2022
Registry last updated
Jun 26, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.