Duke University Medical Center
Durham, North Carolina, 27705, United States
NCT Number: NCT01731015
The goal of this study is to perform a pilot study to evaluate the utilization of oxygen as an inhaled contrast agent to image the airway spaces in normal and diseased human lungs to allow an effect size estimate to power future studies.
Looking for future studies?
Notify Me18 year–90 year
All sexes
Interventional
Phase 1
Durham, North Carolina, 27705, United States
This is an open label study expanding on work by other groups in animals, ex-vivo human lungs and human subjects. Both 2-dimensional and 3-dimensional images will be obtained using 1H MRI comparing images obtained while breathing oxygen to those obtained breathing room air.
Objectives
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
for Lung and/or Airway Disease
Exclusion criteria
for Subjects with Lung and/or Airway Disease:
Subjects presenting with any of the following will not be included in the trial:
Inclusion criteria
for Normal Subjects Subjects must meet all of the following inclusion criteria to be eligible for enrollment into the trial:
Exclusion criteria
for Normal Subjects
Subjects presenting with any of the following will not be included in the trial:
At the study visits, MRI 'studies' will be performed using the same MR scanner (a 3.0-Tesla (T) TRIO MRI system (Siemens Medical Systems)). Lung morphology and function will be acquired using conventional 1H MRI followed by 1H MRI with oxygen as a gaseous contrast agent. For both series the subject will lie down in a supine position on the magnet bed with a standard 1H Torso coil for imaging. Subjects are scanned on room air and then the subjects are switched from room air to 100% oxygen and exhaled O2/CO2 are monitored (Oxigraf Capnograph) until steady state is achieved (in our experience ~ 1-2 minutes). The 100% oxygen MRI imaging is commenced (the average exposure time is usually 5-6 minutes with a maximum exposure of 15 minutes) after which the subjects are switched to room air. After steady state is achieved a second room air scan is completed.
Other names: oxygen
Time frame: one exposure
Assessment of image quality of oxygen enhanced MR images: Signal to Noise Ratio, Dynamic Range of Ratio/Difference Images
Hal C Charles
Other
A Pilot Study for Evaluation of Regional Lung Function in Normal Subjects and Subjects With Airway and Lung Disorders Using 1H Magnetic Resonance Imaging With Oxygen as a Contrast Agent
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT01710449
Asthma, Bronchial Diseases
Durham, North Carolina, United States
View Trial DetailsNCT04574050
Anemia, Anemia, Hemolytic
London, United Kingdom
View Trial DetailsNCT00677560
Asthma, Bronchial Diseases
London, United Kingdom
View Trial DetailsNCT00147069
Asthma, Bronchial Diseases
London, United Kingdom
View Trial Details