NCT Number: NCT04931212

Fetoscopic Endoluminal Tracheal Occlusion (FETO) With Smart-TO

The purpose of this study is to make the proof of concept and to evaluate the safety of fetoscopic endoluminal tracheal occlusion (FETO) using Smart-TO device in fetuses with congenital diaphragmatic hernia and moderate to severe pulmonary hypoplasia

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

Female

Study type

Interventional

Phase

Not applicable

Primary location

Hôpital Béclère, Clamart, France

Loading trial locations.

About this study

Congenital diaphragmatic hernia (CDH) leads to lung hypoplasia and impaired lung vasculature. Fetal lung growth may be stimulated by fetal endoscopic tracheal occlusion (FETO). In severe CDH, FETO may improve survival. In the moderate cases, the prematurity induced by the plug-unplug strategy limits the benefit from the lung growth induced by tracheal occlusion.

One of the main drawbacks of FETO is the need for in-utero reversal of tracheal occlusion by the balloon, as the current procedure involves re-establishment of patent airways either electively at 34 weeks' gestation or earlier if required, ideally at least 24 h before birth. Unfortunately, removal of the balloon is a difficult, invasive, and risky procedure. Furthermore, it requires a specialist team to be able to reverse the occlusion at all times. As a result, it is recommended that the patient stays close to a FETO center during the whole duration of the occlusion, which may limit the acceptability of FETO.

The Smart-TO balloon allows an easy, remotely controlled, and non-invasive reversal occlusion, so it allows to overcome issues related to the airway reestablishment. The technology solution is based on a magnetic valve that opens under the influence of the peripheral magnetic field around a magnetic resonance (MR) scanner. The opening of the valve induces the deflation of the balloon, which is then washed out by the fluid coming out from the lungs.

The purpose of this study is to make the proof of concept and to evaluate the safety of fetoscopic endoluminal tracheal occlusion (FETO) using Smart-TO device in fetuses with congenital diaphragmatic hernia and moderate to severe pulmonary hypoplasia. Secondary objectives include evaluation of prematurity, preterm premature rupture of membranes, lung growth, and survival at discharge in case of FETO with Smart-TO balloon.

FETO with Smart-TO balloon will be performed between 27 and 31wks + 6 days depending on the severity of pulmonary hypoplasia, according to the same technique that is used with the balloon usually used for FETO procedure. The unplug procedure will be performed between 34 and 34wks + 6 days or earlier if required. The patient will be asked to make a peripheral course around the MR scanner in order to open the magnetic valve and induce the deflation of the balloon. Ultrasound scan will be performed before and after the unplug procedure, in order to check the balloon did not deflate spontaneously at the time of the unplug, and to check the balloon deflates thanks to the magnetic fringe field of the MR scan. Expelling of the Smart-TO balloon outside the airways will be check at birth by a thorax X-ray.

Patients will be monitored during the whole duration of the study so serious unexpected or adverse reactions can be recorded.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients aged 18 years or more, who are able to consent, and affiliated to social security
  • Singleton pregnancy with fetus with isolated left-sided congenital diaphragmatic hernia (no additional malformation nor chromosomal abnormality) and:

Severe pulmonary hypoplasia defined as observed on expected 'lung-to-head ration' (O/E LHR) <25% irrespective of the liver position as measured between 27wks and 29wks + 6 days Or Moderate pulmonary hypoplasia defined as O/E LHR 25-34.9% (liver up or down) or O/E LHR 35-44.9% with liver up as measured between 30wks and 31wks + 6 days

Exclusion criteria

  • Maternal contraindication to fetoscopic surgery
  • Preterm premature rupture of the membranes (PPROM) or condition strongly predisposing to PPROM or premature delivery
  • Impossibility of remain close to the FETO center during the fetal occlusion period

Treatment and study plan

FETO with Smart-TO balloon

Procedure

Fetal endoscopic tracheal occlusion using the Smart-TO balloon Unplug procedure by peripheral course around the MR scanner

Other names: Unplug

Primary outcomes

  1. Deflation of the Smart-TO balloon after exposure to the fringe field of the MRI

    Time frame: Between 34 and 34+6 amenorrhea weeks

    No visualization of the balloon at ultrasound scan

  2. Expelling of the Smart-TO balloon outside the airways

    Time frame: At birth

    Thorax X-ray of the neonate

Secondary outcomes

  1. Serious unexpected or adverse reactions

    Time frame: From date of inclusion until discharge date from hospitalization of newborn, up 15 months

    Adverse reactions monitoring during the whole study duration

  2. Spontaneous deflation of the balloon

    Time frame: Between the FETO (27amenorrhea weeks) and the unplug procedure (34 amenorrhea weeks)

    Ultrasound scan

  3. Prematurity

    Time frame: At birth

    Gestational age at birth

  4. Preterm premature rupture of the membranes (PPROM)

    Time frame: from date of inclusion until delivery, up to 37 amenorrhea weeks

    Event of PPROM and gestational age at PPROM

  5. Fetal lung growth

    Time frame: Before the unplug procedure

    O/E LHR measurement

  6. Survival at discharge

    Time frame: From date of inclusion until discharge date from hospitalization of newborn, up to 6 months

    Neonate survival

  7. Survival at 6 months of age

    Time frame: 6 months after birth

    Neonate survival

  8. Oxygen dependence

    Time frame: 6 months after birth

Sponsors and collaborators

Lead sponsor

Assistance Publique - Hôpitaux de Paris

Other

Collaborators

  • URC-CIC Paris Descartes Necker Cochin

Registry information

Official study title

Fetoscopic Endoluminal Tracheal Occlusion (FETO) With Smart-TO Device in Fetuses With Congenital Diaphragmatic Hernia and Moderate to Severe Pulmonary Hypoplasia: Proof of Concept and Safety Evaluation.

Acronym: Smart-FETO

Important dates

Study start
2021
Primary completion
2024
Study completion
2024
First posted
Jun 18, 2021
Registry last updated
Nov 20, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.