Skip to main content
OpenTrials
Completed

NCT Number: NCT01207830

Feasibility Trial of ValenTx Endo Bypass System of the ValenTx Endo Bypass System in Obese Subjects

The purpose of this study is to provide initial clinical data to support the feasibility of use of the ValenTx Endo Bypass system in enhancing weight loss and co-morbidity resolution in morbidly obese subjects

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–55 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Hospital San Jose Tec de Monterrey

Monterrey, Mexico

About this study

This is a single center, open label, feasibility study whose major aim is to determine the feasibility (based on safety, efficacy and device performance) of the ValenTx Endo Bypass system with the replaceable sleeve. Also, the use of a tag replacement device may be developed and implemented should individual attachment tags need replaced following the initial implant.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Male or female between 18 and 55 years of age
  • Subject has a BMI >35 kg/m2 and <= 50 kg/m2, with or without co-morbid conditions(s)
  • Documented failure with non-surgical weight loss methods
  • Willing to comply with study procedures and visit schedule
  • Willing and able to provide informed consent

Exclusion criteria

  • Pregnancy or intention of becoming pregnant within the study duration (Women of childbearing potential participating in the study must have a negative serum pregnancy test result at screening and use a medically acceptable form of contraception. Medically acceptable forms of contraception include oral contraceptives, injectable or implantable methods, intrauterine devices, or properly used double-barrier contraception, eg condom plus diaphragm. If screening pregnancy test is done greater than 7 days before implant, women of childbearing potential must have another serum pregnancy test result before implantation. Any woman becoming pregnant during the treatment period must withdraw from the study)
  • Endoscopic lesions such as important hiatal hernia, gastric or duodenal ulcer, atresias or stenosis, polyps of the stomach
  • Subject with potential upper gastrointestinal bleeding such as esophageal or gastric varices, Mallory-Weis syndrome or congenital or acquired intestinal telangiectasia
  • Past history of esophageal or gastric/GI surgery, obstruction, adhesive peritonitis, or large hiatal hernia (> 3 cm)
  • IBS, unexplained intermittent vomiting, severe abdominal pain or chronic constipation within 60 days of study day 0
  • Unexplained anaemia, Pancreatitis, Portal hypertension, Esophagitis or Barrett's esophagus, known gallstones or anomalies of the GI tract
  • Any bodily infections within 30 days of study day 0 (implant day)
  • Prolonged steroid use
  • Hep C or HIV positive
  • Known allergies to any of the device materials
  • Use of weight loss medication within 2 months prior to enrollment and throughout the study period
  • Recent or ongoing cancer, history of severe renal, hepatic, cardiovascular or pulmonary disease or transplants
  • Inability to tolerate anti-inflammatory medications
  • Evidence of psychiatric problems or dietary habits that would contraindicate study treatment
  • Active drug or alcohol addiction within 12 months of enrollment and throughout the study duration
  • Prior history of inflammatory diseases of the GI tract, (e.g., esophagitis, varices, gastric or duodenal ulceration, or Crohn's disease; congenital or acquired GI anomalies, e.g., bowel strictures)
  • Ongoing treatment with anticoagulants, steroids, aspirin, NSAIDs, or other gastric irritants within 1 month prior to enrollment and throughout the study period
  • Participation in previous (within 60 days of study day 0) or ongoing clinical trial or current or past usage (within 60 days of study day 0) of investigation drug or other device

Treatment and study plan

Endo Bypass System

Device

Subject is implanted with the device for up to 3 years.

Other names: Valentx, EBS

Primary outcomes

  1. Device-related adverse events

    Time frame: 1-3 years

Secondary outcomes

  1. Device Performance

    Time frame: 1-3 years

Sponsors and collaborators

Lead sponsor

ValenTx, Inc.

Industry

Registry information

Official study title

A Single Center Feasibility Trial of the Safety and Efficacy of the ValenTx Endo Bypass System in Obese Subjects

Important dates

Study start
2010
Primary completion
2011
Study completion
2012
First posted
Sep 23, 2010
Registry last updated
Mar 17, 2016

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.