Skip to main content
OpenTrials
Completed

NCT Number: NCT02160561

Feasibility of Upright Bed Position in ARDS Patients

Lower lobe atelectasis of the lung is common in Acute Respiratory Distress Syndrome (ARDS) and has the potential to adversely impact lung compliance and intra-pulmonary shunt. The cephalic shift of the diaphragm and dorsal atelectasis associated with the commonly used supine position might also contribute to this shunt. Reports indicate that obese patients may be more likely to develop dorsal atelectasis than non-obese patients.

The investigators hypothesized that opening the body position angle at the waist from a typical head of bed at 30 degrees to one similar to a more upright reverse trendelenburg position, would alter the position of the diaphragm downward, allowing for improved aeration of lung bases. Thus, the investigators examined the upright body positioning in mechanically ventilated patients with ARDS primarily by evaluating for effects on oxyhemoglobin saturation (O2sat), Tidal Volume (TV) and Respiratory Rate (RR).

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Wake Forest Baptist Health, Medical Intensive Care Unit

Winston-Salem, North Carolina, 27157, United States

About this study

Acute respiratory failure and acute respiratory distress syndrome is a life-threatening occurrence. The annual incidence of ARDS is 141,500 patients, with 59,000 deaths, and a cost of 1,642,000 hospital days/year. Within this population, special care needs of obese patients are becoming a clinically important entity within the Intensive Care Unit (ICU). ICU literature on body positioning for obese mechanically ventilated patients is limited. Currently, intubated obese patients are placed in the supine position with the head of bed elevated at 30 degrees. The 30 degree head up position has been adopted for all patients as a reflection of the Ventilator Associated Pneumonia prevention literature. In all critically ill patients on mechanical ventilation, a cephalic shift of the diaphragm along with dorsal atelectasis of the lung occurs. In obese patients this alteration may be associated with greater degree of impairment in lung compliance and gas exchange as compared to non-obese ventilated patients. It is possible that current ICU body positioning recommendations for obese mechanically ventilated patients may be detrimental due to the obese abdominal compartment hampering normal diaphragm function and position.

In supine, intubated, mechanically ventilated patients it has long been noted that lower lung lobes become atelectatic soon after intubation due to several factors such as accumulation of fluids, air closure, and a cephalic shift of the diaphragm. Obese patients develop more atelectasis during anesthesia than non-obese patients. There have been attempts to correct this iatrogenic complication in critically ill patients such as placement of patients in the prone position. Prone positioning does resolve the dorsal atelectasis and shows improvement in hypoxia. However there is no mortality benefit with prone positioning. Also, continuous lateral rotational patient positioning on mechanical ventilation has shown similar effects7. Specific literature with regards to obese patients and their unique susceptibility towards this phenomenon is limited.

As BMI increases there is an associated reduction of lung volumes, expiatory reserve volume, and functional reserve capacity. It is also known that in the reverse trendelenburg position, there is a gravitational pull allowing abdominal contents to descent toward the pelvis. This position of the abdominal contents allows for a more functional diaphragm position. One observational study 10 conducted a 12 hour intervention which examined upright position with patients' body in a straight line at 40-45 degrees (i.e., reverse trendelenburg-no bend at the waist). This study demonstrated a significant increase in the PaO2/FiO2 ratio (ie, oxygenation) during upright position.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Mechanically ventilated
  • Chest radiograph must show parenchymal lung infiltrates.
  • Acute Lung Injury
  • Study shall occur 96 hours after consent has been obtained

Exclusion criteria

  • Hemodynamic instability and/or use of a vasopressor within the last 6 hours prior to enrollment.
  • Pregnant patients.

Treatment and study plan

Intervention Arm

Other

Placing patients who are in critical illness with acute respiratory failure and are mechanically ventilated in an upright reverse trendelenburg position

Primary outcomes

  1. Number of participants with change in hemodynamic stability from baseline when placed in upright position

    Time frame: Three hours

    Hemodynamic stability will be determined by changes from baseline in blood pressure or heart rate when participants are placed in an upright position.

Secondary outcomes

  1. Number of participants with change in Oxyhemoglobin Saturation from baseline when placed in upright position

    Time frame: Three hours

    Oxyhemoglobin saturation levels will be monitored when participant is placed in upright position. Change from baseline level will be recorded.

  2. Number of participants with Change in Tidal Volume from baseline when placed in upright position

    Time frame: Three hours

    Tidal volume will be monitored when participant is placed in upright position. Change from baseline level will be recorded.

  3. Number of participants with change from baseline in Respiratory Rate when placed in upright position

    Time frame: Three hours

    Respiratory stability will be determined by changes from baseline in respiratory rate when participants are placed in an upright position.

Other outcomes

  1. Number of participants with change from baseline in respiratory system compliance when placed in upright position

    Time frame: Three hours

    Respiratory System Compliance will be determined by changes from baseline in anxiety level and ventilation requirements when participants are placed in an upright position. Participants will be continually monitored and observed to note changes in anxiety on a comfort scale as well as any mechanical ventilator changes to mode, rate, and delivered oxygen percents required for comfort.

Sponsors and collaborators

Lead sponsor

Wake Forest University Health Sciences

Other

Registry information

Important dates

Study start
2013
Primary completion
2015
Study completion
2015
First posted
Jun 10, 2014
Registry last updated
Aug 9, 2018

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.