London Health Sciences Centre
London, Ontario, N6A 5A5, Canada
NCT Number: NCT03276351
This is a prospective randomized control trial that aims to investigate fixation of implants after revision total knee replacement. The investigators are comparing long-stemmed revision implants with hybrid cementation to short-stemmed primary implants with augment using a special type of x-ray imaging (radiostereometric analysis) to assess implant movement over time. The investigators are also comparing costs and patient-reported outcomes between the groups.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
London, Ontario, N6A 5A5, Canada
The demand for total knee replacement (TKR) continues to grow, especially for younger patients who are at a greater risk of outliving the useful lifetime of their implants, thus requiring revision surgery (Aggarwal et al., 2014; Stambough et al., 2014). Rates of revision TKR are growing at an even faster rate than primary TKR. Between 2009-10, the incidence of primary TKR grew by 9.4% in the U.S., while revision TKR grew by 17.1% (Kurtz et al., 2014). Revision occurs for failures such as loosening, infection, or wear. Unfortunately, patients undergoing revision TKR are roughly 6 times more likely to require re-revision compared to patients undergoing primary TKR, further increasing the revision burden. Standard of care for revision TKR has evolved, in search of long-lasting fixation and improved patient outcomes. In many centres, the current standard of care is to use revision TKR implants with long stems for enhanced fixation. Surgeon preference is variable, however, as to whether these stems will be fully cemented, or whether only the most proximal aspect of the baseplate will be cemented (hybrid fixation). While most common, these long-stemmed revision implants have suffered from poor survivorship, are technically demanding to implant, and can result in poor patient outcomes, including ongoing pain. Over the past decade porous metal augments have gained favour. These devices interface between the defective bone and the implant, aiding fixation. The first augment of its kind are the Trabecular Metal cone augments from Zimmer. Although an improvement in principle, they have a number of drawbacks including poor fit with most implant systems, increasing technical challenge and requiring intra-operative customization, which lengthens the surgery. More recently, Stryker Tritanium augments have been introduced that offer a closer fit with Triathlon revision implants, decreasing operative time. This closeness of fit also provides an opportunity to rethink the utilization of long stems when porous augments are used. Ultimately, the goal would be for porous metal augments to completely fill all bone defects, essentially enabling a more primary-like TKR to be performed, enhancing patient outcomes. The gold standard for measurement of implant fixation over time is radiostereometric analysis (RSA). At the time of surgery, 0.8-1.0 mm Tantalum beads (typically n = 6-8 per region of interest) are inserted into the bone surrounding the implant of interest, and occasionally also into the polyethylene liner or insert of the implant. RSA exams are then acquired within the first 2 weeks post-operation, and again at 6 weeks, 3 months, 6 months, 1 year, and 2 years. Each exam involves a stereo x-ray acquisition with a calibration unit to reconstruct the 3D location of the implant relative to the marker beads. Across each exam, the migration of the implant relative to the marker beads is tracked compared to the baseline exam acquired within the first 2 weeks. RSA is extremely precise and accurate, and is able to track migrations on the order of 10's of microns. Large early migrations within the first 1-2 years post-operation are predictive of eventual implant loosening and failure. RSA can also be used to measure inducible displacement of implants to assess instantaneous fixation of implanted components. These RSA exams compare a supine, unloaded image of the patient's joint to a standing, loaded image of their joint, to determine whether any movement occurs between the implant and marker beads with loading. To our knowledge, only three published RSA studies of revision TKR exist in the literature. Jensen et al. (2012) published a 2-year study with 40 patients comparing cement reconstruction to Trabecular Metal cones. They found no significant difference between groups for migration at 2 years, and determined that use of the Trabecular Metal cones resulted in better early stability with reduced irregular motion patterns compared to using hybrid cement reconstruction. Heesterbeek et al. (2016) published a 2-year study with 32 patients that compared hybrid to fully cemented stem fixation using the Legion revision system, which was followed up to 6.5 years by Kosse et al. (2017). At both follow-up time points, there was no difference in overall migration between the hybrid and fully cemented stem groups. Taken together, these studies do not reflect the latest thinking in revision knee surgery, do not account for the current generation of augment design, do not directly compare augments with hybrid and fully cemented fixation, and do not correlate fixation and patient outcome scores.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Long-stemmed revision implant with hybrid fixation for total knee arthroplasty
Short-stemmed primary implant with augmented fixation for total knee arthroplasty
Time frame: 0-2 weeks (baseline exam) to 1 year
Tibial component migration over time measured through radiostereometric analysis
Time frame: Pre-operatively, 6 weeks, 3 months, 6 months, 1 year, and 2 years
Inducible displacement of implants to assess instantaneous fixation of implanted components measured through radiostereometric analysis
Time frame: Surgery
Total costs of implants, bone cement and operating time will be recorded.
Time frame: Pre-operatively, 6 weeks, 3 months, 6 months, 1 year, and 2 years
Patient-reported measure to assess function, pain and stiffness.
Time frame: Pre-operatively, 6 weeks, 3 months, 6 months, 1 year, and 2 years
Patient-reported measure to assess quality of life.
Time frame: Pre-operatively, 6 weeks, 3 months, 6 months, 1 year, and 2 years
Clinician-reported outcome measure to assess function, pain and range of motion.
Time frame: Pre-operatively, 6 weeks, 3 months, 6 months, 1 year, and 2 years
Patient-reported measure to assess quality of life
London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04247802
Arthritis, Hip Arthroplasty
Banbury, Oxfordshire, United Kingdom
View Trial DetailsNCT04467970
Arthritis, Joint Diseases
Asyut, Egypt
View Trial DetailsNCT03081663
Arthritis, Joint Diseases
London, Ontario, Canada
View Trial DetailsNCT07212699
Alzheimer Disease, Arthritis
Munich, Bavaria, Germany
View Trial Details