ETH Zurich, Rehabilitation Engeineering Laboratory
Zurich, 8008, Switzerland
NCT Number: NCT05097612
In this study the LiftSuit version 2.0 designed by Auxivo AG will be used. The LiftSuit is a soft wearable device that is designed to support workers perform physically demanding tasks including repetitive lifting and working in forward leaning positions. It is put on like a backpack and attached to the body using fabric bands and cuffs. Besides soft fabric parts the LiftSuit contains elastics elements. The elastic elements can be flexibly exchanged by the experimenter. For this experiment elastic elements of known stiffness will be hooked into the fabric frame.
Looking for future studies?
Notify Me18 year–65 year
All sexes
Interventional
Not applicable
Zurich, 8008, Switzerland
In a first step participants will try on the LiftSuit exoskeleton and adjust it to their body under supervision of the experimenter. When the LiftSuit exoskeleton is adjusted to the participant it is taken off to allow placement of sensors. The sensors used to record heart rate (Polar H9 heart rate monitor, Polar Electro Europe AG, Germany), muscle activity from 8 muscles in the back and hip region (Delsys Trigno, Delsys Europe, United Kingdom) and movement kinematics (OptiTrack motion capture system, NaturalPoint Inc., USA) will be placed by the experimenter (or participant him/herself). To verify that the electromyography sensors, are working and to obtain normalization values, participants will be instructed to conduct maximal voluntary contractions of each muscle that are being recorded. If needed single sensors can be replaced. After this the exoskeleton will be put back on.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The LiftSuit is a soft passive wearable device that is designed to support the hip and back muscles during forward leaning and lifting. It exerts it function through Elastic Energy Storages (EES). In this condition the EES are removed from the device to create a placebo device.
The LiftSuit is a soft passive wearable device that is designed to support the hip and back muscles during forward leaning and lifting. It exerts it function through Elastic Energy Storages (EES). EES of different three different levels of stiffness (low, medium, high stiffness) will be used.
The LiftSuit is a soft passive wearable device that is designed to support the hip and back muscles during forward leaning and lifting. It exerts it function through Elastic Energy Storages (EES). EES of different three different levels of stiffness (low, medium, high stiffness) will be used.
The LiftSuit is a soft passive wearable device that is designed to support the hip and back muscles during forward leaning and lifting. It exerts it function through Elastic Energy Storages (EES). EES of different three different levels of stiffness (low, medium, high stiffness) will be used.
Time frame: 2 hours
An elastic band placed external to the body parallel to the spine and over the hip joint is likely to support the muscles that extend the hip and back. Less hip extensor muscle (m. gluteus maximus, hamstrings) activity is expected in LiftSuit conditions compared to the placebo comparator condition.
Time frame: 2 hours
An elastic band placed external to the body paralell to the spine and over the hip joint is likely to support the muscles that extend the hip and back. Less back muscle activity (erector spinae at lumbar and thoracic level) is expected in LiftSuit conditions compared to the placebo comparator condition.
Time frame: 2 hours
A reduction in muscle activity is expected. This reduction is expected to be related to the stiffness level of the EES. With high stiffness, leading to more support, leading to less muscle activity.
Time frame: 2 hours
The reduction in muscle activity is expected to be related to the stiffness level of the EES. With high stiffness, leading to more support, leading to less muscle activity.
Time frame: 2 hours
An elastic band placed external to the body over the hip joint is likely to support the muscles that extend the hip. It could be that this setup might heightened levels of activity in the abdomen.
Time frame: 2 hours
Changed forces around the hip joint might influence movement kinematics of this joint. Changes in position and acceleration of the joint angle will be calculated.
Swiss Federal Institute of Technology
Other
"Evaluation of a Soft Exoskeleton With Parallel Springs and Its Ability to Reduce Physical Load During Lifting and Leaning"
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06112106
Occupational Exposure, Occupational Injuries
Ann Arbor, Michigan, United States
View Trial DetailsNCT02661074
Allergy, Anisakiasis
Boulogne-sur-Mer, France
View Trial DetailsNCT05774600
Neoplasms, Neoplasms by Site
Golden, Colorado, United States
View Trial DetailsNCT05849168
Occupational Exposure
Aurora, Colorado, United States
View Trial Details