GSK Investigational Site
Fort Wayne, Indiana, 46825, United States
NCT Number: NCT02928380
In this clinical study, an experimental denture adhesive with a precision tip nozzle was tested to evaluate the relative efficacy to reduce the ingress of food under the denture compared to use of no adhesive or a standard marketed adhesive.
Looking for future studies?
Notify Me18 year–85 year
All sexes
Interventional
Not applicable
Fort Wayne, Indiana, 46825, United States
The aim of this study is to explore the mass of food particle ingress when an adhesive is extruded through the new nozzle with directed application compared to the use of no adhesive and a marketed adhesive (extruded through a flat ribbon nozzle [FRN]) with standard application as per product label, utilizing a peanut occlusion methodology. This was a single center, controlled, single blind (to the examiner performing the safety assessments (oral soft tissue [OST] examination) and the laboratory staff weighing the peanut particles), randomized, three-treatment, three-period, cross-over design in participants with full upper and lower dentures. Each treatment period consisted of one day of testing with at least two days between treatment visits. This study consisted four visits: Visit 1 - Screening Visit; Visit 2 - Treatment 1 Visit; Visit 3 - Treatment 2 Visit and Visit 4 - Treatment 3 Visit.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Participants received a single application of test denture adhesive with a Flat Ribbon Nozzle as 3 Continuous strips those were applied to upper denture and one continuous strip that was applied to the lower denture which were placed in the mouth.
Participants received a single application of marketed denture adhesive with a flat ribbon nozzle as a 3 dabs those were applied to upper denture and 2 dabs those were applied to lower denture, which were placed in the mouth.
Time frame: Up to 17 days
Participants were provided with 30-32 g (accurately weighed) non-salted peanuts, divided into smaller portions of approximately four whole peanuts. Each portion chewed for approximately 20 seconds. After completion of the peanut consumption, participants rinsed their mouth with water, participants may remove any residual peanut particles from their mouth with water and a gauze pad. Participants than removed their dentures. Peanut particles were collected from the fit surfaces of the dentures and the gauzes, and weighed to evaluate the mass of food particles that had migrated under the denture (keeping the particles associated with the upper and lower dentures separate).
Time frame: Up to 17 days
Participants were provided with 30-32 g (accurately weighed) non-salted peanuts, divided into smaller portions of approximately four whole peanuts. Each portion chewed for approximately 20 seconds. After completion of the peanut consumption, participants rinsed their mouth with water, participants may remove any residual peanut particles from their mouth with water and a gauze pad. Participants than removed their dentures. Peanut particles were collected from the fit surfaces of the dentures and the gauzes, and weighed to evaluate the mass of food particles that had migrated under the denture (keeping the particles associated with the upper and lower dentures separate).
Time frame: up to 17 days
Participants were provided with 30-32 g (accurately weighed) non-salted peanuts, divided into smaller portions of approximately four whole peanuts. Each portion chewed for approximately 20 seconds. After completion of the peanut consumption, participants rinsed their mouth with water, participants may remove any residual peanut particles from their mouth with water and a gauze pad. Participants than removed their dentures. Peanut particles were collected from the fit surfaces of the dentures and the gauzes, and weighed to evaluate the mass of food particles that had migrated under the denture (keeping the particles associated with the upper and lower dentures separate).
Time frame: Up to 17 days
Kapur (Olshan modification) Index score was assessed to examine each denture (upper & lower) for retention & stability. Retention was measured as score of 0-5 to assess nature of resistance offered by denture to vertical pull & lateral force: 5=Excellent;4=Very Good;3=Good;2=Fair;1= Poor;0=No retention. Stability was measured as score of 0-4 to assess nature of rocking offered by denture base on its supporting structures under pressure:4=Excellent (no rocking);3=Good (very slight rocking);2=Fair (slight rocking);1=Poor (moderate rocking);0=No stability (extreme rocking). Composite Kapur (Olshan modification) Index scores was measured as the sum score of retention & stability for upper or lower dentures separately such that a sum score of zero represents no retention and stability and a sum score of 9 represents excellent retention and stability.
Time frame: Up to 17 days
Kapur (Olshan modification) Index scores were assessed to examine each denture (upper & lower) for its retention ability. Retention was measured as score of 0-5 to assess nature of resistance offered by denture to vertical pull & lateral force: 5=Excellent - denture offered excellent resistance to vertical pull and lateral force; 4= Very Good- denture offered very good resistance to vertical pull and lateral force; 3= Good- denture offered moderate resistance to vertical pull and lateral force; 2= Fair- denture offered moderate resistance to vertical pull and little or no resistance to lateral forces; 1= Poor- denture offers slight resistance to vertical pull and little or no resistance to lateral force; 0= No retention- when the denture was seated in place, it displaced itself. Higher the score, higher the retention ability of denture.
Time frame: Up to 17 days
Kapur (Olshan modification) Index scores were assessed to examine each denture (upper & lower) for its stability ability. Stability was measured using score of 0-4: 4= Excellent- when denture base offered no rocking on its supporting structures under pressure; 3= Good- when denture base had very slight rocking on its supporting structures under pressure; 2= Fair- when denture base had slight rocking on its supporting structures under pressure; 1= Poor- when denture base had moderate rocking on its supporting structures under pressure; 0= No stability- when denture base had extreme rocking under pressure. Higher the score, higher the stability ability of denture.
GlaxoSmithKline
Industry
A Clinical Study to Evaluate the Ability of an Experimental Denture Adhesive to Prevent Food Particle Ingress Under Dentures
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07273149
Denture Retention
Boston, Massachusetts, United States
View Trial DetailsNCT06866067
Denture Retention
Cairo, Egypt
View Trial DetailsNCT06632548
Denture Retention, Edentulism
Elminia, Egypt
View Trial DetailsNCT05173974
Denture Retention
Indianapolis, Indiana, United States
View Trial Details