Skip to main content
OpenTrials
Completed

NCT Number: NCT06632548

Retention of Three Different Types of Telescopic Attachments

This study was conducted on thirty patients. These patients were divided into three groups in a random manner to compare the retention forces between three different types of secondary crowns used to stabilize two implant mandibular overdentures. in all groups the primary coping was fabricated from milled titanium while the secondary coping was milled titanium in first group ,3D printed cobalt chromium in the second group and milled poly ether ketone ketone in the third group the retention forces was measured using forcemeter immediately after insertion and after 3,6, months

Completed

Looking for future studies?

Notify Me

Key information

Age range

55 year–75 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Faculty of Dentistry Minia University

Elminia, 61631, Egypt

About this study

A thirty edentulous patients Was selected from outpatient clinic of

Exclusion criteria

  • systemic and metabolic disorders that may complicate osseointegration.
  • Patients receiving bisphosphonates.
  • patients receiving radiotherapy. The patients was assigned into three groups using balanced randomly. Patients was randomly allocated into one of three groups using random numbers generated using Excel program.

Group I included patients who received 2 implants and telescopic overdentures with milled titanium primary and secondary coping Group II included patients who received telescopic overdentures with milled titanium primary coping and three dimensionally printed secondary coping GroupIII patients recived milled titanium primary coping and poly ether ketone ketone secondary copings (PEKK) secondary coping All patients signed an informed consent.

Surgical and prosthetic protocols:

A radiographic stent with gutta percha markers at the canine region was fabricated and the patient was instructed to wear it during cone beam radiographic evaluation to evaluate proposed implant sites regarding bone height and thickness, and approximation to vital structures (mental foramen).

Radiographic template was converted to surgical template.

The two implants was inserted nearly parallel as possible. If inclination of the implants was inevitable buccally or lingually due to mandibular concavities, the inclination was compensated later during design of primary copings.

The implants was inserted in the canine region with two steps surgical protocol. After three months of the insertion and osseointegration implants was exposed and healing abutments was inserted after gingival healing implant level impression will be taken.

The metallic primary coping was milled with 2-degree convergence for all cases while the second coping was milled titanium or 3D printed cobalt chromium or milled PEKK according the patient group.

the primary copings was screwed to the implants and the secondary coping pick up was done and patient was instructed to follow oral hygiene measures and was scheduled for periodic follow up every 3 months.

Evaluation of overdenture retention:

Force meter device was used to measure the retention of the mandibular overdenture in Newton.

The patient was seated on upright position and asked to open his mouth until the occlusal surface of the lower denture is parallel to the floor and the maximum dislodging force to remove the denture is recorded using digital forcemeter.

Measurement of retention forces was made immediately after overdenture insertion and repeated at 3,6,9and 12 months after insertion after by independent dental personnel blinded to treatment groups.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • un-satisfaction with the retention of mandibular dentures due to mandibular ridge atrophy and desired to have more stable prosthesis,
  • sufficient remaining bone in height, width and thickness in the interforaminal area to allow installation of at least 3.5mm diameter implants.
  • Adequate amount of interarch space of at least 12mm from the occlusal plane of the mandibular denture to the mucosa of the ridge. Patients with the 4- age range 55 to 75 years.

-

Exclusion criteria

  • systemic and metabolic disorders that may complicate osseointegration. 2) Patients receiving bisphosphonates. 3) patients receiving radiotherapy.

-

Treatment and study plan

telescopic overdenture

Device

two implant retained mandibular overdenture with telescopic attachment

Primary outcomes

  1. retention forces

    Time frame: from insertion time up to one year follow up

    retention forces of three different type secondary coping telescopic attachments used to stabilize two implant mandibular overdenture these attachments are made of either milled titanium, 3D printed cobalt chromium or milled poly ether ketone ketone

Sponsors and collaborators

Lead sponsor

Moatz Aly Ahmed Hussien

Other

Registry information

Official study title

Retention of Three Different Secondary Copings in Telescopic Attchments Used to Stabilize Implant Retained Mandibular Overdenture a Randomized Clinical Trial

Acronym: Overdenture

Important dates

Study start
2022
Primary completion
2024
Study completion
2024
First posted
Oct 9, 2024
Registry last updated
Oct 9, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.