Skip to main content
OpenTrials
Completed

NCT Number: NCT03454113

Ellipsys Vascular Access System Registry

Ellipsys Vascular Access System Registry will enroll up to 100 patients to evaluate the use and performance of the Ellipsys Vascular Access System when it is used within its intended use in accordance with standard of care in a clinical setting. The Ellipsys Vascular Access System is intended for use to create an arteriovenous (AV) fistula via percutaneous access.

Completed

Looking for future studies?

Notify Me

Key information

Sex eligibility

All sexes

Study type

Observational

Primary location

Universitäts-Herzzentrum Freiburg-Bad Krozingen, Bad Krozingen, Germany

Loading trial locations.

About this study

Ellipsys Vascular Access System Registry is a non-randomized, prospective, post-market, multi-center registry of the Ellipsys Vascular Access System in which up to 100 patients will be enrolled to evaluate the use and performance of the Ellipsys Vascular Access System when it is used within its intended use in accordance with standard of care in a clinical setting. The Ellipsys Vascular Access System is intended for use to create an AV fistula via percutaneous access. The primary performance endpoint is Clinical Success at the 90-day endpoint, where Clinical Success is defined as an access site that achieves a venous diameter of greater than or equal to 4 mm and blood flow greater than or equal to 500 ml/min in the brachial artery as measured via duplex ultrasound.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Diagnosed with End-Stage Renal Disease (ESRD) or chronic kidney disease requiring dialysis or anticipated start of dialysis within 6 months of enrollment.
  • Patients deemed medically eligible for upper extremity autogenous AV fistula creation, per institutional guidelines and/or clinical judgment Adequate quality vein base on pre-operative assessment:
  • Vein diameter of > 2.0 mm at target anastomosis site
  • Clinically significant outflow as determined by outflow mapping (ultrasound or v venography)
  • Adequate quality artery base on pre-operative assessment:
  • Arterial lumen diameter of > 2.0 mm at target anastomosis site
  • No significant calcification at the anastomosis site
  • Radial artery at the wrist suitable for catheterization
  • Radial artery-adjacent vein proximity < 1.5 mm measured lumen edge-to-lumen edge as determined by pre-procedural ultrasound and confirmed pre-procedure
  • Patent palmar arch with adequate collateral perfusion as evidenced by Negative Allen's Test
  • Able and willing to follow a daily aspirin and/or other anticoagulation/antiplatelet regimen, not including warfarin (Coumadin, or comparable anti-coagulant)

Exclusion criteria

  • Documented or suspected central venous stenosis including upper extremity arterial stenosis (≥ 50%)
  • History of steal syndrome from a previous hemodialysis vascular access on the ipsilateral side which required intervention or abandonment
  • Evidence of clinically significant vascular disease at the radial artery/adjacent vein site on the ipsilateral side
  • Systolic pressures < 100 mg Hg at the time of treatment
  • Suspected or confirmed skin disease at the skin entry site
  • Immunocompromised patients (e.g. HIV positive)
  • Edema of the upper extremity on the ipsilateral side
  • Patients requiring immunosuppressant therapy such as Sirolimus (Rapamune®) or - Prednisone at a dose of > 10 mg per day
  • Peripheral white blood cell count <1.5 K/mm3 or platelet count <75,000 cells/mm3
  • Known bleeding diathesis or coagulation disorder
  • Receiving warfarin (Coumadin, or comparable anti-coagulant) therapy
  • Patients with acute or active infection

Treatment and study plan

Ellipsys Vascular Access

Device

The Ellipsys Vascular Access System comprises the Ellipsys Catheter, Ellipsys Crossing Needle and Ellipsys Power Controller. The Ellipsys Crossing Needle is used to facilitate access between the artery and the vein. The Ellipsys Catheter is placed percutaneously into the selected vein in close proximity to the selected artery. The Ellipsys Catheter is actuated at the selected anastomosis site, and the vein and artery are approximated. Once the vessels are in the appropriate relative positions the catheter is connected to the Ellipsys Power Controller to create the anastomosis after which the Ellipsys Catheter is removed, and the access site is closed using standard percutaneous closure techniques.

Primary outcomes

  1. The number of patients with a vascular access site that achieves a venous diameter of greater than or equal to 4 mm and blood flow greater than or equal to 500 ml/min in the brachial artery as measured via duplex ultrasound.

    Time frame: 90 days

    Primary endpoint

Secondary outcomes

  1. Percent of Ellipsys Vascular Access procedures that successfully create an arteriovenous fistula (AVF) excluding Access Failures.

    Time frame: 12 months

    Device Success Rate

  2. The length of time until a patient is able to undergo 2-needle cannulation for dialysis OR access vessel has a diameter ≥ 6 mm and a mean flow rate of ≥ 600 ml/min if the patient is not undergoing dialysis.

    Time frame: 12 months

    Time to Functional Patency

  3. Percent of patients that require dialysis and sustain 3 consecutive 2-needle cannulations at the prescribed needle gauge and blood flow rate.

    Time frame: 12 months

    Dialysis Rate

  4. The number of surgical or endovascular interventions required to achieve or maintain Functional Patency.

    Time frame: 12 months

    Secondary Procedure Rate

  5. Number of patients with patency defined as an anastomosis that has flow whether it is being used for dialysis or not.

    Time frame: 12 months

    Arterio-venous fistula patency

  6. Length of time from initial access creation to achieve Functional Patency or to time of abandonment of AVF.

    Time frame: 12 months

    Cumulative patency

Sponsors and collaborators

Lead sponsor

Medtronic Endovascular

Industry

Registry information

Official study title

Ellipsys Vascular Access System Registry, Protocol 1.0. Version 1.0

Important dates

Study start
2017
Primary completion
2019
Study completion
2020
First posted
Mar 5, 2018
Registry last updated
Feb 8, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.