CT Scan
DeviceApplied only when part of the patient's standard care
NCT Number: NCT02524704
The goal of this feasibility study is to evaluate the ability of Electrical Impedance Tomography (EIT) for providing regional and quantitative information about the extent and nature of bronchial obstruction in patients with cystic fibrosis. It is not being conducted to diagnose, treat, prevent, or cure any kind of disease. In electrical impedance tomography low amplitude, low frequency current is applied on electrodes, and the resulting voltage is measured and used to computed the electrical properties of the interior of the chest as they change in time. The computed properties are used to form an image, which can then be used for monitoring and diagnosis.
Looking for future studies?
Notify Me2 year–21 year
All sexes
Observational
The goal of this study is to evaluate the ability of Electrical Impedance Tomography (EIT) hardware and software in patients with cystic fibrosis (CF) for providing regional and quantitative information for identifying regions of obstruction and consolidation, and determine whether these measures will correlate with improvements seen after hospitalized treatment for a pulmonary exacerbation (PE). In particular, EIT will be used to identify regions of obstruction (air trapping) and consolidation comprised of atelectasis and airway occlusion (consequences of mucus plugging) in CF patients, and to determine whether EIT can demonstrate the beneficial effects of antibiotic treatment for CF patients with an acute PE by correlating changes in quantitative EIT measures with clinical measures known to improve following therapy, with patients serving as their own controls. Regional changes in air trapping and consolidation from pre to post treatment as indicated by the EIT images will be calculated, with subjects serving as their own control.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Applied only when part of the patient's standard care
Time frame: 2 years
The sensitivity and specificity of EIT for identifying regions of air trapping and consolidation will be assessed using the CT scan as the gold standard
Time frame: 2 years
The accuracy of the spirometry measures computed from EIT images will be assessed by comparing to those from the pulmonary function tests
Time frame: 2 years
Changes in quantitative EIT measures will be correlated with clinical measures known to improve following therapy, patients serving as their own controls.
Colorado State University
Other
Electrical Impedance Tomography (EIT): A Non-radiating Functional Imaging for Cystic Fibrosis
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02715921
Congenital, Hereditary, and Neonatal Diseases and Abnormalities, Cystic Fibrosis
Irvine, California, United States
View Trial DetailsNCT04798014
Congenital, Hereditary, and Neonatal Diseases and Abnormalities, Cystic Fibrosis
Indianapolis, Indiana, United States
View Trial DetailsNCT03938324
Anemia, Anemia, Hemolytic
Durham, North Carolina, United States
View Trial DetailsNCT05453578
Bacterial Disease Carrier, Bacterial Infections
Tucson, Arizona, United States
View Trial Details