Effectiveness, Safety and Perceptions With the Use of One LED Blanket Device in the Ambulatory Treatment of Jaundice

Objective: to evaluate the effectiveness, safety and level of satisfaction of parents and healthcare team with one innovative device for phototherapy to which a LED light mesh has been incorporated(a blanket), comparing it with the Ohmeda BiliBlanket Plus®. Methods: randomized controlled clinical trial with preterm or low birth weight infants requiring phototherapy. The study protocol was evaluated and accepted by the San Ignacio Hospital and "Pontificia Universidad Javeriana" research committee. Informed consent was requested from parents and the authors declared no conflict of interest. Sample size and allocation: using the STATA 12 program, a sample size of 64 patients was calculated(5% losses), 32 for each group, with significance level of 0.05, power of 80% and difference in bilirubin decreasing of at least 0,1 mg/dl/h with standard deviation of 0.14 mg/dl/h. A computer program randomized the allocation to the intervention and the concealment of the assignment was through sealed opaque envelopes. Seric bilirubin levels were taken at the start and at the end of phototherapy. Controls were done every 2 hours with the Bilicheck spectrophotometer device. Axillary temperature was measured at the beginning of phototherapy, at 30 min, 60 min, and every 2 hours during intervention. Physical examination and recording of side effects related were performed. Parents and health personnel answered a survey on comfort and perceptions with the use of the devices at the end of phototherapy. Analysis: Comparison of means was made for the decrease of bilirubin levels and body temperatures and chi-square for incidence of side effects and results of the survey.

Completed

Looking for future studies?

Notify Me

Key information

Age range

Up to 1 month

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Hospital Universitario San Ignacio

Bogotá, 110231, Colombia

About this study

Background: Jaundice due to hyperbilirubinemia is the most common entity that requires medical management in neonates. About 50% of full-term newborns and 80% of premature infants develop jaundice. The effectiveness of phototherapy for neonatal jaundice depends on two factors: the spectrum of light emitted and the spectral irradiation of light. An ideal phototherapy device should have a broad light emission surface, in order to cover the maximum of the body surface in the horizontal plane, it should be durable, generate relatively little heat and provide a wavelength and light intensity (radiation) optimal (460-490nm and ≥ 30uw / cm2 / nm). The conventional phototherapy devices use fluorescent lamps that emit heat and require eye protectors, in addition to increasing water losses, which requires a permanent monitoring of vital functions and temperature. Its use imposes hospitalization and consequently mother-child separation, always traumatic. The most recent devices use light emitting diodes (LED light) as the light source. Objective: to evaluate the effectiveness, safety and level of satisfaction of parents and healthcare team with one innovative device for phototherapy to which a LED light mesh has been incorporated (one blanket), comparing it with the Ohmeda BiliBlanket Plus®, used at the Kangaroo Mother Care Program for intermittent ambulatory phototherapy. Methods: randomized controlled clinical trial with preterm or low birth weight infants that required phototherapy according to the guidelines of the American Academy of Pediatrics. The Protocol was evaluated and accepted by the "Hospital Universitario San Ignacio and Pontificia Universidad Javeriana research committee". Informed consent was requested from parents and the authors declared no conflict of interest. Sample size and allocation: using the STATA 12 program, a sample size of 64 patients was calculated, 32 for each group, with significance level of 0.05, power of 80% and difference in bilirubin decreasing of at least 0,1 mg/dl/h with standard deviation of 0.14 mg/dl/h and 5% of losses. A computer program randomized the allocation to the intervention and the concealment of the assignment was through sealed opaque envelopes. Seric bilirubin levels were taken at the start and at the end of phototherapy. Controls were done every 2 hours with bilicheck spectrophotometer device. Axillary temperature was measured at the beginning of phototherapy, at 30 min, 60 min, and every 2 hours during intervention. Physical examination, recording of side effects related, mortality and requirement of hospital treatment were performed. Parents and health personnel answered a survey on comfort and perceptions with the use of the devices at the end of phototherapy. Analysis: Comparison of means was made for the decrease of bilirubin levels and body temperatures and chi-square for incidence of side effects, hospitalization, mortality and results of the survey.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Low Risk Hyperbilirubinemia requiring phototherapy according to the guidelines of the American Academy of Pediatrics and recommendations for management of premature infants under 35 weeks, adopted by the Kangaroo Mother Care Ambulatory Program.
  • Start of jaundice at a chronological age greater than 48 hours.
  • Bilirubin level ≤18 mg / dL
  • Knowledge of blood groups of mother and child.
  • Parents are required to sign informed consent where they agree to participate in the study.

Exclusion criteria

  • Parents without availability to stay in the Kangaroo Mother Care Program for at least 6 hours.
  • Extensive skin lesions due to burns or sloughing at the physical examination prior to entering the study.

Treatment and study plan

Neomedlight Phototherapy Blanket

Device

The NeoMedLight® phototherapy blanket is an innovative new fiber-optic device based on LED light. Its light emitting surface area is 40.5x30 cm or 1200 cm2. The device size is 40.5 x30 cm. It incorporates fiber optic mesh and is protected by a vinyl cover and a disposable liner for patient comfort and hygiene. This device provides therapeutic light (404-515nm) to a wide extension of the body surface area. Its average irradiation footprint is 35uW / cm2 / nm ± 15%. The phototherapy was done intermittently in periods of 2 hours with 1 hour of rest for a total time of 6 hours in kangaroo position.

Ohmeda-Fiber Optic Phototherapy Blanket

Device

This device is a high performance version of Ohmeda Medical's Biliblanket that uses a fiber optic cable to deliver light from a high-intensity lamp to a device composed of a fiber optic fabric. The device has a disposable liner and is left in direct contact with the patient. The patient is exposed to a light with a wavelength between 400 and 550 nanometers. The phototherapy system consists of a light emitting unit, a fiber optic cable four feet long (121.9 cm) and a lightweight mattress. It has two available sizes: 4.38 x 9.38 inches (11.12 x 23.83 cm) and 4.00 x 6.00 inches (10.16 x 15.2 cm).

Primary outcomes

  1. Bilirubin change rate in mg/dl/h

    Time frame: through study completion, an average of 6 hours

    Bilirubin lowering rate (initial seric bilirubin- final seric bilirubin/time of phototherapy).

Secondary outcomes

  1. Patient temperature during phototherapy

    Time frame: through study completion, an average of 6 hours

    Axillary temperatures at 30 min, 60 min, 1 hour, 2 hours, 4 hours and 6 hours of phototherapy.

  2. Incidence of skin lesions related to phototherapy

    Time frame: through study completion, an average of 6 hours

    rash, burns, etc... related to phototherapy

  3. Incidence of dehydration related to phototherapy

    Time frame: through study completion, an average of 6 hours

    Dehydration documented with physical examination and weight

  4. Incidence of diarrhea related to phototherapy

    Time frame: through study completion, an average of 6 hours

    Documented diarrhea

  5. Incidence of other side effects related to phototherapy

    Time frame: through study completion, an average of 6 hours

    Other effects recorded in clinic history related to phototherapy

  6. Perceptions of parents with the use of devices

    Time frame: At study completion, an average of 6 hours.

    Comfort with heat, humidity, breastfeeding, proximity and possibility of contact with the baby. The investigators did a validated survey at the end of treatment using a Likert scale(1-7): 1=uncomfortable. 7=comfortable. 4=indifferent

  7. Perceptions of the health team with the use of the devices

    Time frame: At study completion, an average of 6 hours.

    Comfort cleaning and using the device and comfort with light, heat, humidity, and feeding and taking care of the baby. The investigators did a validated survey at the end of treatment using a Likert scale(1-7): 1=uncomfortable. 7=comfortable, 4=indifferent

  8. Hospitalization for hyperbilirubinemia

    Time frame: Between beginning of treatment and 72 hours after

    Rate of hospitalization for hyperbilirubinemia

  9. Mortality

    Time frame: Between beginning of treatment and 72 hours after

    Rate of mortality related to treatment

Sponsors and collaborators

Lead sponsor

Nathalie Charpak

Other

Collaborators

  • Hospital Universitario San Ignacio

Registry information

Official study title

Effectiveness, Safety and Perceptions With the Use of One LED Blanket Device in the Ambulatory Treatment of Neonatal Jaundice

Acronym: LEDlightT2

Important dates

Study start
2016
Primary completion
2017
Study completion
2017
First posted
Jun 26, 2018
Registry last updated
Jul 19, 2018

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.