Trakya University
Edirne, Turkey (Türkiye)
NCT Number: NCT05904574
In this retrospective study, investigators aimed to evaluate the effectiveness of the autologous blood patch method in percutaneous transthoracic lung biopsies performed with the coaxial technique.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Edirne, Turkey (Türkiye)
In this retrospective study, investigators aimed to evaluate the effectiveness of the autologous blood patch method in percutaneous transthoracic lung biopsies performed with the coaxial technique. Biopsies and treatment modalities were performed according to approved guidelines. Ethics committee approval was obtained for the retrospective evaluation of the files and images of the participants. Written informed consent was obtained from all participants before biopsy procedures. Percutaneous transthoracic biopsies (PTB) have been started to be performed with the coaxial technique using the autologous blood patch method as of April 2019 in Interventional Radiology Department of Trakya University Hospital. All lung biopsies are performed using the blood patch method as a standard, as a clear decrease in procedural complications was observed in a short time. Thus, in this study, participants who underwent biopsy after April 2019 formed the participant group that underwent autologous blood patch, and those who had the procedure before this date formed the control group. Since autologous blood patch application was not performed before this date, participant grouping was time-dependent.
All participants included in the study underwent tru-cut biopsy with the coaxial technique. Of the 240 participants included in the study, 120 were treated with an autologous blood patch ( Group A), and the remaining 120 were participants without an autologous blood patch (Group B).
Procedure:
All biopsy procedures were performed by four interventional radiologists with at least 2 years of experience. First of all, after determining the lung lobe where the lesion was observed, axial CT images of 5 mm cross-section thickness were obtained so that the upper and lower parts of it could be visualized. After ruling the entry site in the skin, antisepsis and local anesthesia were performed. The coaxial system (17 G) was cautiously advanced and CT images were continuously evaluated to confirm entrance into the lesion. Approximately 3-4 pieces were taken with the 18 G core biopsy needle until sufficient tissue was obtained. In the autologous blood patch technique, approximately 6-7 ml of blood was taken from the participants with a 10 ml syringe before the procedure. By attaching a 3-way tap to the injector from which the blood is drawn, blood is drawn into a second injector to ensure that the clotted blood is dispersed and homogenized. After the above-mentioned procedures, and after sufficient tissue samples were taken at the last stage of the biopsy procedure, control CT imaging, including the whole lung, was performed to evaluate complications. The presences of pneumothorax were noted. The prepared autologous blood patch was given through the coaxial needle (approximately 1 ml of autologous blood patch was applied for every 1 cm when the coaxial needle was withdrawn) and the tract formed by the biopsy needle in the parenchyma, pleura, and under the skin was closed with the participant's autologous blood. Thus, it was aimed at preventing pneumothorax or reducing its severity if it occurred. The tract formed by the given autologous blood patch into the parenchyma can be observed in most biopsies. The lesion and lung parenchyma features, pneumothorax and other complications of the participants included in the study were evaluated through biopsy planning and follow-up images in hospital medical record system. It is known that transthoracic lung biopsies performed with the coaxial technique increase the diagnostic accuracy. In addition, by obtaining more than one tissue piece with a single entry, more tissue pieces can be sampled for histopathological studies as well as molecular and genetic analysis, which has become increasingly important recently. As a result, investigators think that the use of this method will increase, as more tissue material can be obtained in percutaneous transthoracic lung biopsies performed with coaxial technique and computed tomography using the autologous blood patch method, while reducing the risk of pneumothorax, the most common complication, at the same time.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Approximately 3-4 pieces were taken with the 18 G core biopsy needle until sufficient tissue was obtained. In the autologous blood patch technique, approximately 6-7 ml of blood was taken from the patient with a 10 ml syringe before the procedure. By attaching a 3-way tap to the injector from which the blood is drawn, blood is drawn into a second injector to ensure that the clotted blood is dispersed and homogenized. The prepared autologous blood patch was given through the coaxial needle (approximately 1 ml of autologous blood patch was applied for every 1 cm when the coaxial needle was withdrawn) and the tract formed by the biopsy needle in the parenchyma, pleura, and under the skin was closed with the patient's autologous blood.
After determining the lung lobe where the lesion was observed, axial CT images of 5 mm cross-section thickness were obtained so that the upper and lower parts of it could be visualized. After ruling the entry site in the skin, antisepsis and local anesthesia were performed. The coaxial system (17 G) was cautiously advanced and CT images were continuously evaluated to confirm entrance into the lesion. Biopsy was taken and after sufficient tissue samples were taken at the last stage of the biopsy procedure, control CT imaging, including the whole lung, was performed to evaluate complications. The presences of pneumothorax were noted.
Time frame: first 24 hours
Development of pneumothorax after biopsy as a complication
Time frame: Immediately after procedure
Incidence of patients needing chest tube after biopsy
Trakya University
Other
Evaluation of the the Effectiveness of the Autologous Blood Patch Method in Transthoracic Lung Biopsies Using the Coaxial Technique
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05342675
Lung Cancer, Lung Diseases
San Francisco, California, United States
View Trial DetailsNCT05594485
Artificial Intelligence, Atelectasis
Havířov, Czechia
View Trial DetailsNCT05222568
Lung Cancer, Lung Diseases
Daegu, South Korea
View Trial DetailsNCT03656406
Lung Cancer, Lung Diseases
Daegu, South Korea
View Trial Details