Completed

NCT Number: NCT01689753

Effect of the TEGO Connector in Preventing Tunneled Cuffed Hemodialysis Catheters From Dysfunction and/or Bacteremia

The aim of the trial was to assess whether use of the TEGO connector was able to reduce the incidence of a composite endpoint of TCC-related dysfunction (TCC-D)or TCC-related bacteremia (TCC-B) in chronic hemodialysis (HD) patients carrying the TEGO® connector vs controls receiving trisodium citrate 46.7%.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Erasme Hospital

Anderlecht, Brussels Capital, 1070, Belgium

About this study

The TEGO® connector (ICU Medical, www.icumed.com) is a closed positive pressure system, flushed with 0.9% sodium chloride and attached on the hubs of the TCC. As recommended by the producer, the TEGO® remains during 3 consecutive HD sessions and is changed every week. By constituting a mechanical barrier, it could be an interesting alternative to reduce the intraluminal contamination and the risk of TCC-B.

The TEGO® connector is supposed to provide an automatic positive displacement of fluid at the end of each TCC flush. This positive pressure could prevent the reflux of blood into the TCC lumen, possibly resulting in TCC-D.

As the impact of the TEGO® connector on TCC-D and TCC-B has never been studied, we conducted a randomized controlled study in our center by comparing the anti-thrombotic and anti-infectious efficacy of the TEGO® connector to trisodium citrate 46.7% (Citralock®, Dirinco, www.citra-lock.com) . The global cost of both procedures was also evaluated.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Adult HD patients, prevalent or incident,carrying a tunneled cuffed catheter
  • Tunneled cuffed catheter providing a mean blood flow superior to 250 ml/min
  • Patients having signed an informed consent

Exclusion criteria

  • Mature arterio-venous fistula
  • Episode of TCC-related bacteremia 1 week before randomization

Treatment and study plan

TEGO connector®

Device

trisodium citrate

Drug

Other names: Citralock®

Primary outcomes

  1. Incidence rate of tunneled cuffed catheter-related dysfunction or bacteremia (composite endpoint)

    Time frame: 16 months

    Tunneled cuffed catheter dysfunction was defined by the requirement of urokinase and/or a mean blood flow < 250 ml/min during two consecutive hemodialysis sessions. Tunneled cuffed catheter bacteremia was defined by ≥ 2 positive qualitative and/or quantitative positive blood cultures.

Sponsors and collaborators

Lead sponsor

Erasme University Hospital

Other

Registry information

Official study title

Prevention of Tunneled Cuffed Hemodialysis Catheter-Related Dysfunction and Bacteremia by the TEGO® Connector: A Single-Center Randomized Controlled Trial

Important dates

Study start
2009
Primary completion
2010
Study completion
2011
First posted
Sep 21, 2012
Registry last updated