NCT Number: NCT04935944

Effect of FOV and mA on Metal Artifacts on CBCT

The aim of this study is to evaluate the effect of exposure parameters as milliampere (mA) and field of view (FOV) in CBCT on metal artifact of dental implant.

Completed

Looking for future studies?

Notify Me

Key information

Sex eligibility

All sexes

Study type

Observational

Primary location

Roshan Adel

Cairo, Giza Governorate, 12511, Egypt

About this study

Cone Beam Computed Tomography (CBCT) is considered an important valuable imaging technique in the diagnosis and treatment planning in oral and maxillofacial surgery as well as implant dentistry by means of three dimensional images which provide extra information about the buccolingual dimension of the alveolar bone with more details for bone anatomy and inclination.

To make an accurate diagnosis and treatment planning, we have to obtain images with more details and good resolution and quality which could be achieved by CBCT. However, there are some issues in scanned areas that can affect their quality such as presence of metals (metallic restorations, orthodontic appliances, dental implants, crowns) which result in artifacts which can be considered as an important cause of poor image quality which will lead to poor diagnosis.

There are many types of artifacts which can be observed on CBCT images. Beam hardening artifact is considered a common one which occurs when an x-ray beam comprised of polychromatic energies passes through an object, resulting in selective attenuation of lower energy photons. The effect is conceptually similar to a high-pass filter, in that only higher energy photons are left to contribute to the beam and thus the mean beam energy is increased ("hardened").

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Bio models of jaw with dummy implant.

Exclusion criteria

-

Treatment and study plan

CBCT radiation

Radiation

CBCT scanning

Primary outcomes

  1. Dental implant linear measurement

    Time frame: 2 months

    The implant length and width in millimeters will be assessed in the presence of the artifacts with change in the potential difference of FOV and mA

Sponsors and collaborators

Lead sponsor

Cairo University

Other

Registry information

Official study title

Effect of Variations of Field of View (FOV) and Milliampere (mA) on Metal Artifacts Produced by Dental Implants in Cone Beam Computed Tomography Image Quality. (In-vitro Study)

Important dates

Study start
2021
Primary completion
2023
Study completion
2023
First posted
Jun 23, 2021
Registry last updated
Oct 24, 2024