Skip to main content
OpenTrials
Completed

NCT Number: NCT02964754

Digital Three-dimensional Imaging Models for Repair of Complex Long Bone Fractures

To verify whether digital three-dimensional model-assisted internal fixation can obtain better effects in the repair of complex long bone fractures compared with conventional internal fixation.

Completed

Looking for future studies?

Notify Me

Key information

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

About this study

History and current related studies The internal fixator is difficult to completely fit the bone surface at the site of complex long bone fracture, which reduces the firmness of fixation. From a safety point of view, the establishment of a digital three-dimensional measurement model is undoubtedly a very reliable and intuitive way. Digital three-dimensional models are established after CT scan, and these models can greatly reflect the site and degree of fractures, and reduce anatomical parameters, with high degree of simulation and feasibility.

Adverse events

  • The investigators will record adverse events, including screw loosening and falling off, steel plate fracture and bending, joint stiffness, delayed healing or non-healing, peripheral nerve injury and infection.
  • If severe adverse events occur, investigators will report details, including the date of occurrence and measures taken to treat the adverse events, to the principle investigator and the institutional review board within 24 hours.

Data collection, management, analysis and open-access

  • Data collection: Case report forms with demographic data, disease diagnosis, accompanying diseases, drug allergy history, and adverse events will be collected, processed using Epidata software (Epidata Association, Odense, Denmark), collated, and then recorded electronically by data managers using a double-data entry strategy.
  • Data management: The locked electronic database will be accessible and locked only by the project manager, and will not be altered. All data regarding this trial will be preserved by the Affiliated Hospital of Qinghai University, China.
  • Data analysis: The electronic database will be statistically analyzed by a professional statistician who will create an outcome analysis report that will be submitted to the lead researchers. An independent data monitoring committee will supervise and manage the trial data, ensuring a scientific and stringent trial to yield accurate and complete data.
  • Data open access: Anonymized trial data will be published at www.figshare.com.

Statistical analysis

  • Statistical analysis will be performed using SPSS 19.0 software, and will follow the intention-to-treat principle. Normally distributed measurement data will be expressed as mean ± standard deviation, and minimums and maximums. Non-normally distributed measurement data will be expressed as lower quartile (q1), and median and upper quartile (q3).
  • Fisher's exact test will be performed for comparison of total efficacy and the incidence of adverse reactions preoperatively and 6 months postoperatively. Mann Whitney U test will be used to compare Harris score, Visual Analogue Scale, operation time and hospital stay between the two groups. The significance level will be α = 0.05.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Long bone fractures in the four limbs, such as middle segment of humerus, femur, ulna, radius, tibia and fibula; fractures are not related to the articular surface
  • Diagnosed with complex long bone fractures via X-ray
  • Admission within 6 hours after injury

Exclusion criteria

  • Pathological fractures with vascular and nerve injuries
  • Split fractures of the humeral head
  • Neer IV fractures
  • Humeral head compression area greater than 40%
  • Glenohumeral dislocation
  • Conscious disturbance, cerebral infarction, tumor, serious medical complications, such as heart, lung, kidney failure, severe hypertension, diabetes and blood diseases
  • History of elbow joint dysfunction or shoulder joint disease
  • Unwilling to sign the informed consent

Treatment and study plan

CT scan for internal fixation

Device

In the observation group, digital three-dimensional models will be established by CT scan for internal fixation.

conventional internal fixation

Procedure

In the control group, patients will undergo conventional internal fixation.

Primary outcomes

  1. X-ray examination

    Time frame: postoperative 6 months

    To evaluate total efficacy at postoperative 6 months

Secondary outcomes

  1. Harris scores

    Time frame: preoperatively and 6 months postoperatively

    To assesse the recovery of hip function

  2. Visual Analogue Scale

    Time frame: preoperatively and 6 months postoperatively

    To evaluate the pain, and the high score represents severe pain.

Sponsors and collaborators

Lead sponsor

Qinghai University

Other

Registry information

Official study title

Digital Three-dimensional Imaging Models for Repair of Complex Long Bone Fractures: a Randomized Controlled Trial With 6-month Follow-up

Important dates

Study start
2014
Primary completion
2016
Study completion
2016
First posted
Nov 16, 2016
Registry last updated
Feb 9, 2018

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.