Skip to main content
OpenTrials
Completed

NCT Number: NCT05913492

Difficult Airway Simulation-based Training

Difficult airways remain a significant problem in anaesthesia, intensive care and emergency medicine. Simulation-based training gives better outcomes compared to non-simulation and non-intervention education. However, it remains unclear how long the acquired skills are retained and how often simulation training should repeat. The study aimed to investigate the efficacy and skills retention in training for difficult airway management in anaesthesiologists. After ethical committee approval, we conducted a prospective control study at the postgraduate Department of Surgery, Anaesthesiology and Intensive Therapy (Bogomolets National Medical University) from July to December 2022. Anaesthesiologists who applied for the continuous medical education course "Difficult airways management" were involved in the study. The simulation room included a mannequin Laerdal SimMom Advanced Patient Simulator, vital monitor, anaesthesia station LEON and airway devices. Each volunteer went through two simulation scenarios of difficult airway management: 1) "cannot intubate, can ventilate" (CI), 2) "cannot intubate, cannot ventilate" (CICV) with the assistance of the training centre operator. The primary endpoints included: more than three laryngoscopy attempts; supraglottic airway attempt missing; call for help skip; failure to initiate a surgical airway (for the CICV scenario). Secondary endpoints included: time to call for help; mean duration of desaturation; use of bougie; use of video laryngoscope (Airtraq); mean number of intubation attempts; improper usage of equipment of equipment, time to initiation of surgical airway preparation; time to initiation of surgical airway ventilation.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–70 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Bogomolets NMU

Kyiv, Ukraine

About this study

After ethical committee approval, we conducted a prospective control study at the postgraduate Department of Surgery, Anaesthesiology and Intensive Therapy (Bogomolets National Medical University) from July to December 2022. Anaesthesiologists who applied for the continuous medical education course "Difficult airways management" were involved in the study. We obtained consent from them to participate anonymously as volunteers. Before the first training, we interviewed all participants about their experience in working in the speciality, difficult airways management, learning at any simulation training and difficult airways training particularly.

The simulation room included a mannequin Laerdal SimMom Advanced Patient Simulator, vital monitor, anaesthesia station LEON and airway devices. Standard settings included modelling of tongue oedema to grade 4 visualizations on laryngoscopy according to the Cormack and Lehane classification, as well as additional pharyngeal obstruction and stiffness of both lungs for the "cannot ventilate" scenario. A standard set of tools and equipment for ensuring airway patency, ventilation and tracheal intubation included facemasks, oropharyngeal and nasal airways, laryngoscopes, laryngeal masks, and tracheal tubes in a range of sizes. The trolley for difficult airways was available for each station and was equipped with additional laryngoscope blades of various sizes, a video laryngoscope, laryngeal masks of various sizes (Igel), introducers for tracheal tubes (stylets and bougies), Airtraq, a cricotomy kit.

Monitoring provided SpO2, EtCO2, ECG and non-invasive blood pressure measurement. When the oxygen delivery was interrupted for 20 seconds or more, the SpO2 gradually decreased by 3% every 5 seconds and reached 90% after 20 seconds. A value of SpO2 < 90% was considered desaturation. Effective ventilation was defined after at least two effective breaths evidenced by an EtCO2 curve on the monitor.

Each volunteer went through two simulation scenarios of difficult airway management: 1) "cannot intubate, can ventilate" (CI), 2) "cannot intubate, cannot ventilate" (CICV) with the assistance of the training centre operator. Participants were expected to follow an algorithm according to the Difficult Airway Society (DAS) recommendations [4].

During the scenario, we recorded significant deviations from the DAS protocol and other indicators that impacted the quality of the algorithm execution. The primary endpoints included significant deviations from the DAS protocol: more than three laryngoscopy attempts; supraglottic airway attempt missing; call for help skip; failure to initiate a surgical airway (for the CICV scenario). Secondary endpoints included: time to call for help; mean duration of desaturation; use of bougie; use of video laryngoscope (Airtraq); mean number of intubation attempts; improper usage of equipment of equipment, time to initiation of surgical airway preparation; time to initiation of surgical airway ventilation Following the first simulation round, volunteers were trained on the same day in difficult airway management according to DAS guidelines, using the same equipment as during the simulation. The participants repeated the simulation scenarios immediately after the training and six months later. The primary and secondary endpoints were compared between three rounds: initial simulation (Group 1), immediately after training (Group 2), and six months after training (Group 3).

Statistical analysis was performed using licensed Microsoft Office Excel and web source www.socscistatistics.com. We used Student's, Kruskal-Wallis and Fisher's exact tests. The difference was considered significant at α < 5% (p < 0.05).

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

Adult anesthesiologists volunteers

Exclusion criteria

Refusion to participate, age more than 70 years

Treatment and study plan

SIMULATION TRAINING

Behavioral

Each volunteer went through two simulation scenarios of difficult airway management: 1) "cannot intubate, can ventilate" (CI), 2) "cannot intubate, cannot ventilate" (CICV) with the assistance of the training centre operator. Following the first simulation round, volunteers were trained on the same day in difficult airway management according to DAS guidelines, using the same equipment as during the simulation. The participants repeated the simulation scenarios immediately after the training and six months later.

Primary outcomes

  1. Significant deviations from the DAS protocol

    Time frame: 2 hours

    more than three laryngoscopy attempts

Secondary outcomes

  1. Other deviations from DAS protocol

    Time frame: 2 hours

    use of bougie

Sponsors and collaborators

Lead sponsor

Bogomolets National Medical University

Other

Registry information

Official study title

Difficult Airway Simulation-based Training in Anaesthesiologists: Efficacy and Skills Retention Within Six Months After Training

Important dates

Study start
2022
Primary completion
2022
Study completion
2023
First posted
Jun 22, 2023
Registry last updated
Jun 22, 2023

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.