NCT Number: NCT04510753
Collect continuous systolic and diastolic blood pressure values and waveforms as recorded by an arterial line catheter and by non-invasive blood pressure (NIBP) and to collect Photoplethysmogram Pulse Oximetry (PPG) waveform in order to optimize the Sensifree algorithm.
Looking for future studies?
Notify Me18 year–80 year
All sexes
Observational
San Francisco, California, 94121, United States
Sensifree is developing a continuous non-invasive blood pressure measurement system, that uses a fingertip PPG sensor as a signal source. The system provides systolic, diastolic and mean arterial pressure values, for use in hospitals and other clinical settings. The PPG waveform is analyzed by a proprietary software algorithm, calculating BP values.
The current best method to obtain similar information is by using an Arterial line catheter which will serve as a reference device. In this study, the sponsor aims to prospectively collect continuous radial arterial line & PPG waveforms, as well as NIBP data over the period of the surgery in order to test and refine the algorithm.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Invasive monitoring of blood pressure via catheterization of the radial artery, displaying a continuous pressure waveform and blood pressure values.
PPG fingertip mounted sensor, that measures the oxygen level (oxygen saturation) of the blood and generates a waveform
A blood pressure cuff is used to measure blood pressure. The cuff has an inflatable rubber bladder that is typically fastened around the arm. A pressure meter indicates the cuff's pressure.
Time frame: The length of each procedure, typically up to 8 hours
PPG signal will be acquired from the PPG sensor, while blood pressure values (systolic, diastolic, mean) will be acquired from A-line. PPG signal will be analyzed by the Sensifree's algorithm and compared to the A-line BP measurement results according to ISO 81060-2 accuracy specifications
Sensifree Ltd.
Industry
Evaluation of Sensifree's Algorithm for Continuous Blood Pressure Measurements Based on a PPG Sensor's Signal Compared to Invasive Radial Arterial Line
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06915376
Blood Pressure Measurement
Konya, Konya/Meram, Turkey (Türkiye)
View Trial DetailsNCT07024472
Blood Pressure, Blood Pressure Measurement
Helsinki, Finland
View Trial DetailsNCT04976452
Blood Pressure Measurement
Youngstown, Ohio, United States
View Trial DetailsNCT04132453
Blood Pressure Measurement
Holon, Israel
View Trial Details