Skip to main content
OpenTrials
Completed

NCT Number: NCT04249479

Contrast Media Temperature and Patient Comfort in CT of the Abdomen

Abdominal computed tomographic (CT) is an important prognostic tool with regard to the detection of oncological, infectious and other abdominal disorders.

The total iodine load (TIL) is regarded as a decisive factor in the opacification of parenchymal structures. The EICAR trial demonstrated that injection with high flow rates of prewarmed contrast media (CM) was safe and patients did not experience any pain, stress of discomfort during injection. Flow rates as high as 8.8 ml/s were injected without any discomfort. All concentrations used (e.g. 240, 300 and 370 mg I/ml) in this study were prewarmed. According to the recent recommendations (ESUR guidelines 10.0) it should be considered to warm iodine-based CM before administration. The hypothesis is that although using CM at room temperature (~23°C [~73°F]) might result in lower attenuation of the liver parenchyma than would be achieved using CM pre-warmed to body temperature, diagnostic image quality, patient safety and comfort will not be compromised by not pre-warming CM in this setting. According to the guidelines, it is regarded as best clinical practice to pre-warm CM. Surprisingly, these recommendations are merely based on a hypothetical assumption. In the literature, there are no studies evaluating this topic and it has never been clearly shown to result in a better patient comfort. For this reason, many clinics do not pre-warm their CM in daily clinical routine. Only one study evaluated subjective comfort in hysterosalpingography (HSG), in which CM is injected in to the cavity of the uterus. This study found that prewarmed CM alleviates the pain and decreased the incidence of vasovagal episodes during HSG. To the best of our knowledge, no study showed that prewarmed CM in CT resulted in higher patient comfort, in comparison to CM at room temperature (20° C).

Up till now, all CM in the department is prewarmed. In case this study does not show a difference in patient comfort, prewarming the CM can be stopped, resulting in a considerable simplified workflow.

The hypothesis is that usage of CM at room temperature (20° C) might result in a decreased level of patient comfort in abdominal CT, in comparison to pre-heated (37° C) CM, with no significant difference in diagnostic attenuation of the liver parenchyma between groups.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

MaastrichtUMC

Maastricht, Limburg, 6229 HX, Netherlands

About this study

Abdominal computed tomography (CT) scans are performed daily on a regular basis. Since its advent, rapid technical advances in CT continuously improved image quality. Besides scan technique, the contrast media (CM) injection protocol is the crucial factor in abdominal imaging. Parenchymal contrast enhancement is determined by patient related factors (e.g. cardiac output, blood volume and patient weight), the CM injection protocol and the scan protocol. Much literature has been performed with regard to optimizing CM application and the scan protocol. Flow rate of the CM and patient discomfort have been thoroughly investigated in our department. Heating CM up to body temperature has been daily clinical routine in our department for years.

According to the recent recommendations (ESUR guidelines 10.0) it is advised to warm iodine-based CM before administration. Warming the CM is expected to result in a higher patient comfort, based on clinical observation. Kok et al. showed in phantom experiments that high temperature, low iodine concentration and low viscosity significantly decreases injection pressure. Subsequently, as increased temperature reduces the viscosity of the CM, the decreased viscosity is hypothesized to reduce the risk of extravasation. A decreased viscosity might also have a substantial impact on individual tailored CM injection protocols in daily routine scanning as it is speculated that a decrease of viscosity and subsequent decrease in peak injection pressure could influence patient comfort during injection. The EICAR trial showed that prewarmed CM can be safely injected at high flow rates, without patient discomfort, pain or stress. However, the latter was not compared to CM at room temperature.

Different CM concentrations are used in different hospitals throughout the world. The higher the concentration, the higher the viscosity of the CM. In present study, only one CM concentrations (e.g. 300 mg/ml) will be used, which is used in daily clinical practice for years. Heating the CM decreases the viscosity. It is therefore expected that the preheated CM in a concentration of 300 mg/ml has a lower viscosity in comparison to the CM at 20° C.

Pre-warming CM might be regarded as best clinical practice. No studies have been performed to investigate this statement, nor is there any literature that shows that prewarmed CM has a favorable patient comfort compared to CM injected at room temperature. For these reasons, there remains to be some reluctance and many clinics still not pre-warm their CM. One study, in which CM is injected in to the cavity of the uterus to check for any anatomical variants and causes for infertility, showed a preference for prewarmed CM in hysterosalpingography (HCG). This study found that prewarmed CM alleviates the pain and decreased the incidence of vasovagal episode during the HCG.

The hypothesis is that although using CM at room temperature (~23°C [~73°F]) might result in lower attenuation of the liver parenchyma than would be achieved using CM pre-warmed to body temperature, diagnostic image quality, patient safety and comfort will not be compromised by not pre-warming CM in this setting. Pre-warming CM requires special equipment and more complex planning and logistics. On the other hand, pre-warming CM may yield higher attenuation levels, comfort and image quality. In case this study does not show a significant difference in patient comfort and diagnostic quality between groups, pre-warming the CM can be stopped, resulting in a considerable simplified workflow.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients referred for abdominal CT
  • Patient ≥ 18 years old and competent to sign informed consent

Exclusion criteria

  • Hemodynamic instability
  • Pregnancy
  • Renal insufficiency defined as glomerular filtration rate (GFR) < 30ml/min/1.73m2 (Odin protocol 004720)
  • Iodine allergy (Odin protocol 022199)
  • Age < 18 year
  • Unable to give informed consent or no informed consent obtained
  • Inability to position an 18 gauge cannula in an antecubital vein

Treatment and study plan

CM Temperature (20° C)

Other

CM will be administered at 20° C (room temperature).

CM Temperature (37° C)

Other

CM will be administered at 37° C (pre-heated).

weight

Other

The patients' weight is measured prior to scanning by a technician on a weighing scale available in the scanner room.

Primary outcomes

  1. Liver attenuation

    Time frame: Expected within one month after the CT is performed

    Mean attenuation in Hounsfield Units (HU) is based on three liver segments, preferably segments 2, 5 and 8 (Couinaud classification). Absolute difference in mean attenuation of the liver parenchyma between groups was calculated with a two-sided 95% confidence interval of the difference.

Secondary outcomes

  1. Patient comfort

    Time frame: Immediately after CT

    Patient (dis)comfort during and after injection of CM with varying temperatures, rated on a questionnaire

  2. Pain during injection

    Time frame: Questionnaire immediately after CT

    Assessed with a questionnaire with the option yes/no

  3. Pain rate

    Time frame: Questionnaire immediately after CT

    Assessed with a 11-point numeric rating scale (0=no pain; 10=very severe pain)

  4. Different physiological reactions and sensations injection

    Time frame: Immediately after the CT

    Questionnaire has to be filled in which people can tick a box if they had feelings of shivering/goosebumps/or being cold. There is some free space to write down other sensations.

  5. Objective image quality - Signal-to-noise ratio

    Time frame: Within one month after the CT is performed

    mean attenuation of the liver divided by the mean standard deviation

  6. Objective image quality - Contrast-to-noise ratio

    Time frame: Within one month after the CT is performed

    Mean liver attenuation minus HU of the left paraspinal muscle, divided by the SD of the attenuation of the paraspinal muscle

  7. Subjective image quality

    Time frame: Within one month after the end of the study

    Rated in consensus on a 5-point Likert scale by two readers

  8. Body weight

    Time frame: Right before the scan is performed

    Weight is measured on a weighing scale

  9. CM volume

    Time frame: Information is expected to be collected from the Certegra form available in Impax within 1 month

    The milliliter of CM administered

  10. Flow rate

    Time frame: Information is expected to be collected from the Certegra form available in Impax within 1 month

    Flow rate of the contrast media in ml/s

  11. Injection site

    Time frame: Information is expected to be collected from the Certegra form available in Impax within 1 month

    Injection site of the CM

  12. Catheter Gauge

    Time frame: Information is expected to be collected from the Certegra form available in Impax within 1 month

    Catheter size used for CM injection

  13. Effective milliamperes (mAs)

    Time frame: Information is expected to be collected from the Certegra form available in Impax within 1 month

    The effective mAs used in the specific patient

  14. CT Dose Index (CTDI)vol

    Time frame: Information is expected to be collected from Impax within 1 month

    CTDIvol (in mGy) the patient received

  15. Dose-length product (DLP)

    Time frame: Information is expected to be collected from Impax within 1 month

    DLP (in mGycm) the patient received

  16. Tube voltage

    Time frame: Information is expected to be collected from Impax within 1 month

    Tube voltage used in the specific scan

Sponsors and collaborators

Lead sponsor

Maastricht University Medical Center

Other

Registry information

Official study title

The Effect of ContrAst Media Temperature on Patient Comfort in Computed tomograpHY of the Abdomen.

Acronym: CATCHY

Important dates

Study start
2020
Primary completion
2020
Study completion
2020
First posted
Jan 31, 2020
Registry last updated
Apr 2, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.