Yale University
New Haven, Connecticut, 06511, United States
NCT Number: NCT04350307
The aim of the study was to quantify the difference between a 22-gauge needle and 25-gauge needle during lumbosacral epidural steroid injection in regards to intravascular uptake and pain perception. There is the notion that a smaller gauge needle may lead to less intravascular uptake and less pain.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
New Haven, Connecticut, 06511, United States
Inadvertent intravascular injection has been suggested as the most probable mechanism behind serious neurological complications during transforaminal epidural steroid injections. There is the notion that a smaller gauge needle may lead to less intravascular uptake and less pain. The aim of the study was to quantify the difference between a 22-gauge needle and 25-gauge needle during lumbosacral transforaminal epidural steroid injection in regards to intravascular uptake and pain perception.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
22-gauge Quincke needle used for epidural injection
25-gauge Quincke needle used for epidural injection
Time frame: During the procedure
The intravascular uptake percentage reported in the study is the percent of 'needles' that showed intravascular uptake. Hence higher 'intravascular uptake percentage' means worse outcome. The mean percentages were averaged across participants were compared between treatment arms.
Presence or absence of intravascular uptake during live fluoroscopy and/or blood aspiration per needle. Once needle reached its target (epidural space), contrast was injected to confirm the presence or absence of intravascular uptake via live fluoroscopy or aspiration was attempted using a syringe to confirm the presence or absence of intravascular uptake. If contrast pattern suggested needle was in a vessel or blood was aspirated using a syringe, outcome measure was marked 'PRESENT'. If contrast pattern suggested needle was not in a vessel and no blood was aspirated using a syringe, outcome measure was marked 'ABSENT'. In other words, primary outcome measure was binary in nature.
Time frame: During the procedure
Patient reported pain during the procedure (on initial needle entry) on the numerical rating scale (NRS 1-10). Higher numbers implies higher severity of pain. Lower numbers implies lower severity of pain
Yale University
Other
Differential Rates of Intravascular Uptake and Pain Perception During Lumbosacral Transforaminal Epidural Steroid Injection Using a 22-gauge Needle Versus 25-gauge Needle
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07025161
Neurologic Manifestations, Pain
Orlando, Florida, United States
View Trial DetailsNCT05283980
Acute Pain, Behavior
Boston, Massachusetts, United States
View Trial DetailsNCT06869369
Behavior, Motor Activity
Kütahya, Turkey (Türkiye)
View Trial DetailsNCT07729020
Anxiety, Anxiety Disorders
Genoa, Liguria, Italy
View Trial Details