Comparison of Alignment Achieved Using the VELYS Robotic-Assisted Solution Versus Manual Instrumentation in Total Knee Arthroplasty

The purpose of this post-market research study is to gather clinical and radiographic (X-ray) information about total knee replacement surgeries completed with the VELYS Robotic-Assisted Solution and with standard manual instrumentation. The VELYS Robotic-Assisted Solution helps the surgeon to plan bone cuts and then accurately achieve the planned cuts during the total knee replacement surgery. The study aims to compare how well the VELYS Robotic-Assisted system enables the surgeon to position the implants exactly as planned compared to manual instrumentation.

Completed

Looking for future studies?

Notify Me

Key information

Age range

22 year–85 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Sinai Hospital of Baltimore, Baltimore, Maryland, United States

Loading trial locations.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Subject is male or female and between the ages of 22 and 85 years at the time of consent, inclusive.
  • Subject has a severely painful and/or severely disabled joint resulting from osteoarthritis, post-traumatic arthritis or rheumatoid arthritis and in the opinion of the Investigator, is a suitable candidate for primary TKA using the devices described in this CIP with either resurfaced or non-resurfaced patellae.
  • Subject that is willing to give voluntary, written informed consent to participate in this clinical investigation and authorize the transfer of his/her information to the Sponsor
  • Subject is currently not permanently bedridden, as determined by the Investigator
  • Subject, in the opinion of the Investigator, is able to understand this clinical investigation and is willing and able to perform all study procedures and follow-up visits and co-operate with investigational procedures.
  • Subject is able to read and comprehend the Informed Consent Document as well as complete the required PROs in English.
  • Subject's pre-operative alignment is such that (in the opinion of the Investigator) it is appropriate for it to be adjusted to mechanical long leg alignment during surgery.

Exclusion criteria

  • The Subject is a woman who is pregnant or lactating.
  • Contralateral knee has already been enrolled in this study.
  • Subject had a contralateral amputation.
  • Previous partial knee replacement (unicompartmental, bicompartamental or patellofemoral joint replacement), patellectomy, high tibial osteotomy or primary TKA in affected knee.
  • Subject has an active local or systemic infection
  • Subject has loss of bone or musculature, osteoporosis, neuromuscular compromise or vascular deficiency in the affected limb in sufficient degree to render the procedure unjustifiable in the opinion of the Investigator (e.g. absence of musculo-ligamentous supporting structures, joint neuropathy)
  • Subject has severe instability secondary to advanced loss of osteochondral structure or the absence of collateral ligament integrity.
  • Subject has participated in a clinical investigation with an investigational product (drug or device) in the last three (3) months.
  • Subject is currently involved in any personal injury litigation, medical-legal or worker's compensation claims.

Treatment and study plan

Total knee replacement

Device

Subjects will be implanted with an ATTUNE Primary total knee replacement.

Primary outcomes

  1. Accuracy of the Hip-Knee-Ankle Angle (HKA) Measured on Long-leg X-rays at 12 Weeks.

    Time frame: 12 weeks

    The primary objective of this clinical investigation is to evaluate whether the accuracy to plan of the long leg alignment achieved with VELYS Robotic-Assisted Solution is non-inferior to the accuracy to plan of the long leg alignment achieved with the manual ATTUNE Intuition instrumentation. This will be assessed by measuring the Hip-Knee-Ankle angle (HKA) on long-leg X-rays taken at 12 weeks and comparing to the planned HKA. A smaller number represents improved accuracy and a better outcome.

Secondary outcomes

  1. Accuracy of the Distal Femoral Varus-valgus Angle Measured on Long Leg X-rays at 12 Weeks.

    Time frame: 12 weeks

    The accuracy of the distal femoral varus-valgus angle was assessed by comparing the angle measured on an X-ray 12 weeks post operatively to the angle that the surgeon was targeting or planning intra operatively. A smaller number represents improved accuracy and a better outcome.

  2. Accuracy of the Proximal Tibial Varus-valgus Angle Measured on Long-leg X-rays at 12 Weeks

    Time frame: 12 weeks

    The accuracy of the proximal tibial varus-valgus angle was assessed by comparing the angle measured on an X-ray 12 weeks post operatively to the angle that the surgeon was targeting or planning intra operatively. A smaller number represents improved accuracy and a better outcome.

  3. Accuracy of Femoral Component Flexion Angle Measured on Lateral X-rays at 12 Weeks

    Time frame: 12 weeks

    The accuracy of the femoral component flexion angle was assessed by comparing the angle measured on a lateral X-ray 12 weeks post operatively to the angle that the surgeon was targeting or planning intra operatively. A smaller number represents improved accuracy and a better outcome.

  4. Accuracy of the Tibial Slope Angle Measured on Lateral X-rays at 12 Weeks

    Time frame: 12 weeks

    The accuracy of the Tibial slope angle was assessed by comparing the angle measured on a lateral X-ray 12 weeks post operatively to the angle that the surgeon was targeting or planning intra operatively. A smaller number represents improved accuracy and a better outcome.

  5. Type and Frequency of Adverse Events

    Time frame: 12 weeks, 1 year

    Rate of local Adverse events and local serious adverse events reported within the first 90 days and the first year post surgery. Local means at the site of the procedure (i.e. the operated Knee). Serious adverse events are events that required medical or surgical intervention to prevent a serious impairment to health.

  6. Soft Tissue Damage

    Time frame: Day of operation (intraoperative)

    Investigators conducted an intra-operative assessment of the condition and function of key soft tissue structures in both Manual and Robotic-assisted cohorts.

Other outcomes

  1. EuroQol 5-Dimension 5-Level (EQ-5D-5L) - Change From Baseline

    Time frame: 1 year

    The descriptive system comprises five dimensions: mobility, self-care, usual activities, pain/discomfort and anxiety/depression. Each dimension has 5 levels: no problems, slight problems, moderate problems, severe problems and extreme problems. The patient is asked to indicate his/her health state by ticking the box next to the most appropriate statement in each of the five dimensions. Scores are derived by a 5 digit code. The higher the number, the better the overall health status of the patient with 1 (meaning full health) and 0 (meaning a state as bad as being dead).

  2. Forgotten Joint Score (FJS-12)

    Time frame: 12 weeks and 1 year

    The Forgotten Joint Scores comprise measures for the assessment of joint-specific patient-reported outcome (PRO). These PRO questionnaires focus on patients' awareness of a specific joint in everyday life. Joint awareness can be simply defined as any unintended perception of a joint. This may include strong sensations like pain, but also includes more subtle feelings like mild stiffness, subjective dysfunction, or any discomfort. The FJS-12 score ranges from 0 to 100, with 0 being the worst score and 100 being the best. A higher score means the patient is better able to forget about the artificial joint in daily life. So, the higher the score, the better the outcome is.

  3. Knee Injury and Osteoarthritis Outcome Score (KOOS) ADL - Change From Baseline

    Time frame: 12 weeks, 1 year

    A knee-specific instrument that derives a score developed to assess the patients' opinion about their knee and associated problems. The maximum total score is 100 indicating no symptoms and the minimum is 0 indicating extreme symptoms.

  4. Knee Injury and Osteoarthritis Outcome Score (KOOS) Pain - Change From Baseline

    Time frame: 12 weeks, 1 year

    A knee-specific instrument that derives a score developed to assess the patients' opinion about their knee and associated problems. The maximum total score is 100 indicating no symptoms and the minimum is 0 indicating extreme symptoms.

  5. Knee Injury and Osteoarthritis Outcome Score (KOOS) Symptoms - Change From Baseline

    Time frame: 12 weeks, 1 year

    A knee-specific instrument that derives a score developed to assess the patients' opinion about their knee and associated problems. The maximum total score is 100 indicating no symptoms and the minimum is 0 indicating extreme symptoms.

  6. Knee Injury and Osteoarthritis Outcome Score (KOOS) Sports and Recreation - Change From Baseline

    Time frame: 12 weeks, 1 year

    A knee-specific instrument that derives a score developed to assess the patients' opinion about their knee and associated problems. The maximum total score is 100 indicating no symptoms and the minimum is 0 indicating extreme symptoms.

  7. Knee Injury and Osteoarthritis Outcome Score (KOOS) Quality of Life - Change From Baseline

    Time frame: 12 weeks, 1 year

    A knee-specific instrument that derives a score developed to assess the patients' opinion about their knee and associated problems. The maximum total score is 100 indicating no symptoms and the minimum is 0 indicating extreme symptoms.

  8. Subject Satisfaction With Knee Replacement

    Time frame: 12 weeks, 1 year

    A single patient reported question that asks the patient to score their level of satisfaction with their knee from 0-10, with 0 being fully satisfied and 10 being fully unsatisfied

  9. Pain - Change From Baseline

    Time frame: 12 weeks, 1 year

    Subjects are asked how much knee pain they have had in the last week while resting (0-10) and during activity (0-10) with 0 being no pain and 10 being worst pain, therefore lower score is a better outcome.

  10. Learning Curve

    Time frame: 12 Weeks

    The effect of learning curve on the accuracy was assessed by comparing the accuracy between the first 10 cases each surgeon completed and the subsequent cases. The accuracy was assessed by measuring the Hip-Knee-Ankle angle (HKA) on long-leg X-rays taken at 12 weeks and comparing to the planned HKA. A smaller number represents improved accuracy and a better outcome.

Sponsors and collaborators

Lead sponsor

DePuy Orthopaedics

Industry

Registry information

Official study title

Comparison of Alignment Achieved Using the VELYS Robotic-Assisted Solution Versus Manual Instrumentation in Total Knee Arthroplasty: A Prospective, Non-Randomized Multi-Center Post-market Clinical Investigation

Important dates

Study start
2021
Primary completion
2023
Study completion
2023
First posted
Jan 29, 2021
Registry last updated
Apr 27, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.