Total knee replacement
DeviceSubjects will be implanted with an ATTUNE Primary total knee replacement.
NCT Number: NCT04730271
The purpose of this post-market research study is to gather clinical and radiographic (X-ray) information about total knee replacement surgeries completed with the VELYS Robotic-Assisted Solution and with standard manual instrumentation. The VELYS Robotic-Assisted Solution helps the surgeon to plan bone cuts and then accurately achieve the planned cuts during the total knee replacement surgery. The study aims to compare how well the VELYS Robotic-Assisted system enables the surgeon to position the implants exactly as planned compared to manual instrumentation.
Looking for future studies?
Notify Me22 year–85 year
All sexes
Interventional
Not applicable
Sinai Hospital of Baltimore, Baltimore, Maryland, United States
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Subjects will be implanted with an ATTUNE Primary total knee replacement.
Time frame: 12 weeks
The primary objective of this clinical investigation is to evaluate whether the accuracy to plan of the long leg alignment achieved with VELYS Robotic-Assisted Solution is non-inferior to the accuracy to plan of the long leg alignment achieved with the manual ATTUNE Intuition instrumentation. This will be assessed by measuring the Hip-Knee-Ankle angle (HKA) on long-leg X-rays taken at 12 weeks and comparing to the planned HKA. A smaller number represents improved accuracy and a better outcome.
Time frame: 12 weeks
The accuracy of the distal femoral varus-valgus angle was assessed by comparing the angle measured on an X-ray 12 weeks post operatively to the angle that the surgeon was targeting or planning intra operatively. A smaller number represents improved accuracy and a better outcome.
Time frame: 12 weeks
The accuracy of the proximal tibial varus-valgus angle was assessed by comparing the angle measured on an X-ray 12 weeks post operatively to the angle that the surgeon was targeting or planning intra operatively. A smaller number represents improved accuracy and a better outcome.
Time frame: 12 weeks
The accuracy of the femoral component flexion angle was assessed by comparing the angle measured on a lateral X-ray 12 weeks post operatively to the angle that the surgeon was targeting or planning intra operatively. A smaller number represents improved accuracy and a better outcome.
Time frame: 12 weeks
The accuracy of the Tibial slope angle was assessed by comparing the angle measured on a lateral X-ray 12 weeks post operatively to the angle that the surgeon was targeting or planning intra operatively. A smaller number represents improved accuracy and a better outcome.
Time frame: 12 weeks, 1 year
Rate of local Adverse events and local serious adverse events reported within the first 90 days and the first year post surgery. Local means at the site of the procedure (i.e. the operated Knee). Serious adverse events are events that required medical or surgical intervention to prevent a serious impairment to health.
Time frame: Day of operation (intraoperative)
Investigators conducted an intra-operative assessment of the condition and function of key soft tissue structures in both Manual and Robotic-assisted cohorts.
Time frame: 1 year
The descriptive system comprises five dimensions: mobility, self-care, usual activities, pain/discomfort and anxiety/depression. Each dimension has 5 levels: no problems, slight problems, moderate problems, severe problems and extreme problems. The patient is asked to indicate his/her health state by ticking the box next to the most appropriate statement in each of the five dimensions. Scores are derived by a 5 digit code. The higher the number, the better the overall health status of the patient with 1 (meaning full health) and 0 (meaning a state as bad as being dead).
Time frame: 12 weeks and 1 year
The Forgotten Joint Scores comprise measures for the assessment of joint-specific patient-reported outcome (PRO). These PRO questionnaires focus on patients' awareness of a specific joint in everyday life. Joint awareness can be simply defined as any unintended perception of a joint. This may include strong sensations like pain, but also includes more subtle feelings like mild stiffness, subjective dysfunction, or any discomfort. The FJS-12 score ranges from 0 to 100, with 0 being the worst score and 100 being the best. A higher score means the patient is better able to forget about the artificial joint in daily life. So, the higher the score, the better the outcome is.
Time frame: 12 weeks, 1 year
A knee-specific instrument that derives a score developed to assess the patients' opinion about their knee and associated problems. The maximum total score is 100 indicating no symptoms and the minimum is 0 indicating extreme symptoms.
Time frame: 12 weeks, 1 year
A knee-specific instrument that derives a score developed to assess the patients' opinion about their knee and associated problems. The maximum total score is 100 indicating no symptoms and the minimum is 0 indicating extreme symptoms.
Time frame: 12 weeks, 1 year
A knee-specific instrument that derives a score developed to assess the patients' opinion about their knee and associated problems. The maximum total score is 100 indicating no symptoms and the minimum is 0 indicating extreme symptoms.
Time frame: 12 weeks, 1 year
A knee-specific instrument that derives a score developed to assess the patients' opinion about their knee and associated problems. The maximum total score is 100 indicating no symptoms and the minimum is 0 indicating extreme symptoms.
Time frame: 12 weeks, 1 year
A knee-specific instrument that derives a score developed to assess the patients' opinion about their knee and associated problems. The maximum total score is 100 indicating no symptoms and the minimum is 0 indicating extreme symptoms.
Time frame: 12 weeks, 1 year
A single patient reported question that asks the patient to score their level of satisfaction with their knee from 0-10, with 0 being fully satisfied and 10 being fully unsatisfied
Time frame: 12 weeks, 1 year
Subjects are asked how much knee pain they have had in the last week while resting (0-10) and during activity (0-10) with 0 being no pain and 10 being worst pain, therefore lower score is a better outcome.
Time frame: 12 Weeks
The effect of learning curve on the accuracy was assessed by comparing the accuracy between the first 10 cases each surgeon completed and the subsequent cases. The accuracy was assessed by measuring the Hip-Knee-Ankle angle (HKA) on long-leg X-rays taken at 12 weeks and comparing to the planned HKA. A smaller number represents improved accuracy and a better outcome.
DePuy Orthopaedics
Industry
Comparison of Alignment Achieved Using the VELYS Robotic-Assisted Solution Versus Manual Instrumentation in Total Knee Arthroplasty: A Prospective, Non-Randomized Multi-Center Post-market Clinical Investigation
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04748510
Arthritis, Joint Diseases
Subiaco, Western Australia, Australia
View Trial DetailsNCT04092153
Arthritis, Joint Diseases
London, United Kingdom
View Trial DetailsNCT06032442
Arthritis, Joint Diseases
Saint Petersburg, Sankt-Peterburg, Russia
View Trial DetailsNCT03913442
Arthritis, Joint Diseases
New York, United States
View Trial Details