High tibial osteotomy using TOMOFIX
ProcedureTOMOFIX: A guidepin is placed to determine the level and length of the osteotomy with an appropriate hinge position selected. The oscillating saw is then used along with osteotomes to complete the osteotomy under image intensifier guidance. This is opened to the desired width of correction with a trapezoidal gap noted when using laminar spreader in the posterior position to avoid slope change. The plate is then applied and secured as per manufacturers operative technique.
Other names: TOMOFIX