Video Laryngoscopy
DeviceEndotracheal intubation using video laryngoscopy
Other names: Storz c-mac laryngoscopy
NCT Number: NCT04628611
This is a randomized control study where adult patients had been divided randomly into two equal groups using video laryngoscope in group (V) and flexible intubating laryngoscope in group (F)
Looking for future studies?
Notify Me20 year–60 year
All sexes
Interventional
Not applicable
Routine pre-operative assessment including history taking, clinical examination, and laboratory tests. Patients were admitted to the operating room with a small 20G IV cannula after applying inclusion & exclusion criteria and airway assessment by applying El Ganzuri multivariate risk index for difficult intubation which include assessment of the following : inter-incisor gap, Mallampati classification, head &neck movement, buck teeth prognathism, thyromental distance, body weight and history of difficult intubation.
Operating room was prepared using :
Difficult airway cart that includes different size oral airways, endotracheal tubes, different sizes face masks & laryngeal airway masks Suction apparatus to be ready for use Video laryngoscopy The flexible intubating laryngoscopy with the tube mounted over the fiberscope before the procedure.
Standard monitoring devices were applied including ECG, non invasive blood pressure. pulse oximetry and capnography after intubation Patients were then pre-oxygenated via face mask for three minutes and using 0.01 mic/kg atropine then general anesthesia is induced using fentanyl 1-2 mic/kg followed by propofol 2 mg/kg and esmeron 0.5 mg/kg.
The patient is mechanically ventilated using face mask until full relaxation is established after 3-5 minutes. The intubation is done using video laryngoscope in group (v) or using flexible intubating laryngoscopy in group (f) In the first group (v) The video laryngoscope was introduced with the patient appropriately positioned, the operator used the left hand to introduce the video laryngoscope into the midline of the Oropharynx and gently advances until the blade tip pass the posterior portion of the tongue. Using video visualization, the ETT was then advanced on a smooth curve through the glottis and intubation proceeds. Viewing the entire insertion step on the video screen allows the operator to quickly become facile with the motion of gently rotating or angling the tube using the right hand to redirect as necessary.
In the second group(f) patients positioned supine with the operator standing at the head of the bed. Simple chin lift and jaw thrust may improve the view through the flexible laryngoscopy and also help to prevent airway obstruction. The endotracheal tube should be lubricant to facilitate its subsequent advancement into the trachea. Once the endotracheal tube is in place, the scope is removed, and the patient is ventilated. Flexible intubating laryngoscopy is often performed with the operator looking through the eyepiece. However, connecting the flexible laryngoscopy to a monitor is often advantageous.
After collecting demographic data of the patient (age, sex, body mass index & ASA) The following parameters will be measured :
Intubation time, Hemodynamic parameters, success rate and number of attempts & incidence of complications.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Endotracheal intubation using video laryngoscopy
Other names: Storz c-mac laryngoscopy
Endotracheal intubation using flexible intubating laryngoscope
Other names: Storz flexible intubation video endoscope set
Time frame: Through study completion (Assessment done at the same time of doing intubation) within 60 seconds
time from initiation of intubation (application of the laryngoscope into mouth) to ETCO2 detection from the ETT. In cases with failed intubation it was considered from initiationof intubation till failure. Measured by seconds
Time frame: At the same time of doing the intubation within 15 minutes
Measured by(beat/ minute). measured during baseline (just before induction of anesthesia), 3 minutes & 10 minutes after intubation.
Time frame: AT the same time of doing the intubation within 30 minutes
Airway instrumentation will be interrupted if oxygen saturation decreases below 92% and patients are ventilated via a face mask. After 3 failed trials the procedure is considered unsuccessful with insertion of classical LMA of appropriate size, correct placement should be confirmed by capnography, manual ventilation with 100% oxygen should be done and awaken the patient
Time frame: From time of intubation till end of surgery and extubation within 10 hours
sore throat, mucosal or pharyngeal injury, and esophageal intubation, marked desaturation and unsatisfactory blood gases
Time frame: At the same time of intubation within 15 minutes
Measured by mm/Hg measured during baseline (just before induction of anesthesia), 3 minutes & 10 minutes after intubation.
National Cancer Institute, Egypt
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07730918
Hemodynamic Instability During Anesthesia, Induction Anesthesia
Zhangjiagang, Jiangsu, China
View Trial DetailsNCT05825560
Intubation
Nîmes, Gard, France
View Trial DetailsNCT05719194
Intubation, Mechanical Ventilation
Bordeaux, France
View Trial DetailsNCT07125495
Infection, Infections
Istanbul, Turkey (Türkiye)
View Trial Details