University of Science Malaysia Hospital
Kubang Kerian, Kelantan, 16150, Malaysia
NCT Number: NCT03130413
The aim of this randomized study is conducted is to evaluate the performance and safety of air-Q intubating laryngeal airway as primary airway device in various short surgical procedure in children compared to Ambu® AuraGain™ Laryngeal Mask. Current Supraglottic airway devices (SADs) available in are classic LMA (cLMA), proseal LMA (pLMA), supreme LMA (sLMA) and the newer is Ambu® AuraGain™laryngeal mask. As variety of newer SADs for children have emerged since their introduction in clinical practice, hope the outcomes of this study it help advancing our knowledge and acumen in selecting appropriate devices for paediatric population.
Looking for future studies?
Notify Me1 year–6 year
All sexes
Interventional
Not applicable
Kubang Kerian, Kelantan, 16150, Malaysia
JUSTIFICATION OF STUDY
In view of no clinical data is available evaluating the clinical performance and safety of air-Q and Ambu® AuraGain™ in children, therefore this prospective and randomized study is conducted. Most of previous randomized studies in term of safety did not compare the hemodynamic stability.Hope the outcomes of this study it help advancing our knowledge and acumen in selecting devices for paediatric population.
RESEARCH HYPOTHESES
METHODOLOGY
This is a prospective, single blinded and randomized controlled trial study will be conducted at Operation Theatre (OT), Hospital University Sains Malaysia (HUSM). involving paediatric patients scheduled for various surgical procedures within 2 hours where supraglottic airway management would be appropriate..
Sample size calculation For objective 1, sample size was calculated using power and sample size software and the data based on previous study by V.Darlong et al (Comparison of air-Q and Ambu Aura-i for controlled ventilation in infants: a randomized controlled trial). In this study, the time for successful insertion for air-Q is 16.53±1.53 and Ambu Aura-I is 14.68±2.83. Considering power of 80% and type error-I α of 5%, the sample size was required is 15 participants in each group. 10% is added for drop out sample. Therefore sample size, n 15 + (0.1x15) = 17 participants for each group.
For objective 2, sample size was calculated using power and sample size software and the data based on previous study by V.Darlong et al (Comparison of air-Q and Ambu Aura-i for controlled ventilation in infants: a randomized controlled trial). In this study, the OLP for air-Q is 20.21±4.62 and Ambu Aura-I is 16.21±5.66. Considering power of 80% and type error-I α of 5%, the sample size was required is 22 participants in each group. 10% is added for drop out sample. Therefore sample size, n 22 + (0.1x22) = 25 participants for each group.
Overall sample size is estimated using objective 2 because of larger sample size. Total sample size is 50 patients.
SAMPLING METHOD Patients are randomly assigned into 2 groups: air-Q (A) and Ambu® AuraGain™ (B) using computer-generated randomization. Sequentially-numbered sealed opaque envelopes containing group allocation as determined by computer-generated sequence, will be opened by a nurse in charge for study device preparation.
RECRUITMENT OF SUBJECT & INFORMED CONSENT SEEKING Paediatric patients who meets the study criteria, their parents will be approached to invite patients participate in this study. Each parent will be given a thorough explanation along with copy of Patient Information Sheet. All questions that the participant's parents have, will be answered to their satisfaction before consent been obtained by signing the consent form.
The study is divided into screening, pre-operative, intra-operative and post-operative period.
Haemodynamic parameters such as blood pressure (BP), heart rate (HR), oxygen saturation (SpO2) and end tidal carbon dioxide (EtCO2) is recorded at different interval namely, pre induction, post induction, post insertion, every 2 minutes for 10 minutes and then 5 minutes thereafter until extubation.
Anesthesia is maintained with sevoflurane (Minimum Alveolar Concentration value of 1.0-1.2) in Oxygen: Air mixture of 50% . Pressure controlled ventilation is set and targeting the minute ventilation to achieve normocarbia (EtCO2 35-40 mmHg). Intra-operative analgesia is supplement by suppository paracetamol 20 mg/kg or diclofenac sodium 1mg/kg.
Measurement of parameters
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Anesthesia is induced with sevoflurane in oxygen. The anesthesia plane is gradually deepened by increasing the inspired concentration of sevoflurane (2-8%) till the loss of eyelash reflex. After intravenous (IV) cannula is inserted and intravenous fentanyl 1mcg/kg and rocuronium 0.6mg/kg are administered. Use of neuromuscular blocking agent is to minimize the risk of reflex activation of the airway. After 3 minutes, the appropriate size (depending upon body weight) of Ambu Aura Gain is lubricated with water soluble lubricant (KY jelly) is inserted by investigator based on manufacturer recommendation with the patient's head in neutral position. The cuff then is inflated to an intra-cuff pressure of 40 cm H20, measured using a digital cuff pressure monitor.
Anesthesia is induced with sevoflurane in oxygen. The anesthesia plane is gradually deepened by increasing the inspired concentration of sevoflurane (2-8%) till the loss of eyelash reflex. After intravenous (IV) cannula is inserted and intravenous fentanyl 1mcg/kg and rocuronium 0.6mg/kg are administered. Use of neuromuscular blocking agent is to minimize the risk of reflex activation of the airway. After 3 minutes, the appropriate size (depending upon body weight) of Air-Q supraglottic airway is lubricated with water soluble lubricant (KY jelly) is inserted by investigator based on manufacturer recommendation with the patient's head in neutral position. The cuff then is inflated to an intra-cuff pressure of 40 cm H20, measured using a digital cuff pressure monitor.
Time frame: 5 minutes after insertion of the device when good tidal volume is achieved
Flexible fibreoptic scope is use to view anatomical alignment of the device to the larynx, 1cm proximal to the ventilating orifice
Time frame: 5 minutes after insertion of the device when good tidal volume is achieved
OLP is recorded by observing the peak airway pressure which audible leak occur at the first time when fresh gas flow delivered at 3 litre/min and the expiratory valve is completely closed
Time frame: Throughout the insertion process up to 5 minutes post induction
Measure number of attempts of inserting the devices
Time frame: The time from which the device first being hold until successful insertion up to 5 minutes post induction
Measure the time of successful insertion of the devices
Time frame: Time from pre-induction until 5 minutes post insertion
Documented the blood pressure (BP) is recorded at different time interval
Time frame: Time from pre-induction until 5 minutes post insertion
Recorded the heart rate (HR) is recorded at different interval
Time frame: Time from pre-induction until 5 minutes post insertion
Oxygen saturation (SpO2) is recorded at different interval
Time frame: Time from pre-induction until 5 minutes post insertion
The EtCO2 is recorded at different time interval
Time frame: Throughout the stay in recovery bay within 30 minutes after operation
Presence of adverse effect of the device postextubation
Universiti Sains Malaysia
Other
Comparing the Effectiveness Between Air-Q Intubating Laryngeal Airway and Ambu® AuraGain™ Laryngeal Mask for Controlled Ventilation in Paediatric Patients: A Randomized Controlled Trial.
Acronym: Nira
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07673003
Airway Control, Airway Devices
Multan, Punjab Province, Pakistan
View Trial DetailsNCT07092046
Anesthesia Circuit, Anesthesia Equipment Bacterial Contamination
Ankara, Turkey (Türkiye)
View Trial DetailsNCT04760912
General Anaesthesia, Muscle Weakness
Zagreb, Croatia
View Trial DetailsNCT06748898
General Anaesthesia, Perioperative Analgesia
Shanghai, Yangpu, China
View Trial Details