Clinical Variations and Pain Assessment in Newborns Submitted to Intratracheal Aspiration With Open and Closed System

To compare clinical effects identified in infants undergoing intratracheal aspiration with open and closed systems and verify the presence and intensity of pain in newborns during intratracheal suction, according to the system applied.Clinical, randomized, controlled, and crossover study, performed at two neonatal intensive care units after approval by the ethics committee. The sample consisted of infants from zero to seven days of age, 26 weeks of gestational age, and the exclusion criteria were use of mechanical ventilation with high-frequency oscillatory, in use of inhaled nitric oxide, in the acute phase of circulatory failure, central nervous system disorders, without reactivity to stimulus, severe asphyxia, Apgar score less than three in the fifth minute, as well as, presence of chromosomal abnormalities and congenital malformations. After obtaining the informed consent from the responsible, children were randomly allocated into the experimental (CS) and control (OS) groups. The dependent variables of this study respiratory rate (RR), peripheral oxygen saturation (SatpO2), heart rate (HR), blood pressure (BP) and pain, as well as, of the complementary variables, were collected through observation, the Premature Infant Pain Profile (PIPP) scale application and medical records consultation. During the data collection the period of variables observation were: T1 (immediately before suctioning), T2 (during suctioning), T3 (immediately after) and T4 (10 minutes after). To the statistical analysis were applied Fisher exact test, McNemar, Binomial, Student t test, Wilcoxon and Mann Whitney, settling at 0.05 level of significance.

Completed

Looking for future studies?

Notify Me

Key information

Age range

1 hour–28 day

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Federtal university of São Paulo, São Paulo, Brazil

Loading trial locations.

About this study

Background: Patients who underwent tracheal intubation require intratracheal tube secretions sucking, and open system (OS) or closed system (CS) can be used, in order to preserve the tracheal tube permeability and an adequate ventilation and blood oxygenation. Respiratory and hemodynamic complications, as well as, presence of pain can be possibly experienced in newborns submitted to such procedure. Objectives: To compare clinical effects identified in infants undergoing intratracheal aspiration with OS or CS and verify the presence and intensity of pain in newborns during intratracheal suction, according to the system applied. Methods: Clinical, randomized, controlled, and crossover study, performed at two neonatal intensive care units after approval by the ethics committee. The sample consisted of infants from zero to seven days of age, 26 weeks of gestational age, and the exclusion criteria were use of mechanical ventilation with high-frequency oscillatory, in use of inhaled nitric oxide, in the acute phase of circulatory failure, central nervous system disorders, without reactivity to stimulus, severe asphyxia, Apgar score less than three in the fifth minute, as well as, presence of chromosomal abnormalities and congenital malformations. After obtaining the informed consent from the responsible, children were randomly allocated into the experimental (CS) and control (OS) gruops. The dependent variables of this study respiratory rate (RR), peripheral oxygen saturation (SatpO2), heart rate (HR), blood pressure (BP) and pain, as well as, of the complementary variables, were collected through observation, the Premature Infant Pain Profile (PIPP) scale application and medical records consultation. During the data collection the period of variables observation were: T1 (immediately before suctioning), T2 (during suctioning), T3 (immediately after) and T4 (10 minutes after). To the statistical analysis were applied Fisher exact test, McNemar, Binomial, Student t test, Wilcoxon and Mann Whitney, settling at 0.05 level of significance. Results: The studied groups did not show significant differences concerning the complementary variables. There were no statistically significant influences regarding the use of OS and CS of intratracheal suction in any of the dependent variables studied. Clinical consequences were observed with the use of both systems. It was demonstrated that immediately after intratracheal aspiration, the newborns had higher RR average in OS (58,4±9,6) group when compared to CS (56,2±5,9). Average values of SatpO2 were lower in OS (90,5±4,8) group compared to CS (91,6±4,6). Bradycardia was not verified in any group, however, there was a trend toward higher mean values of HR immediately after intratracheal aspiration, especially with OS (149,5±17,4) compared with the values identified before the procedure (143,2±18,1). There was low variation in the mean BP value in the two groups during the period of assessment, using both techniques. Regarding pain it was found that, with OS the average score was 7,9±4,4 and 6,5±3,8 with CS, demonstrating presence of mild to moderate pain. During the use of OS intratracheal aspiration higher pain scores (p=0,038) where verified in newborn females compared to males, this result was not observed when using CS. Conclusion: There was no statistically significant difference regarding the clinical implications, the presence and intensity of pain observed in ventilated newborns, according to the use of OS or CS to intratracheal aspiration.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • infants from zero to seven days of age.
  • 26 weeks of gestational age.
  • responsible concordance in participation

Exclusion criteria

  • use of mechanical ventilation with high-frequency oscillatory.
  • use of inhaled nitric oxide.
  • acute phase of circulatory failure.
  • central nervous system disorders.
  • without reactivity to stimulus.
  • severe asphyxia.
  • Apgar score less than three in the fifth minute.
  • Presence of chromosomal abnormalities and congenital malformations

Treatment and study plan

Tracheal aspiration close system

Device

use of closed system in comparision to open system to tracheal aspiration of nweborns, analyzing pain and climical variations associated.

Other names: aspiration system, suctioning system, tracheal suctioning system

Primary outcomes

  1. Pain response to tracheal suction

    Time frame: 48 hours

    There were no statistically significant influences regarding the use of open (OS) or close system (CS) to intratracheal suction in this dependent variable. With OS the average score was 7,9±4,4 and 6,5±3,8 with CS, demonstrating presence of mild to moderate pain.

Sponsors and collaborators

Lead sponsor

Federal University of São Paulo

Other

Registry information

Official study title

Clinical Variations and Pain Assessment in Newborns Submitted to Intratracheal Aspiration With Open and Closed System.

Important dates

Study start
2010
Primary completion
2010
Study completion
2010
First posted
Jan 13, 2011
Registry last updated
Jan 13, 2011

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.