Beijing Anzhen Hospital, Capital Medical University
Beijing, China
NCT Number: NCT06021509
To validate the safety and efficacy of transcatheter edge-to-edge repair (TEER) using the NovoClasp® transcatheter mitral valve clip and steerable guide catheter in the treatment of moderate to severe and severe degenerative mitral regurgitation (DMR).
This study is active but is not currently recruiting participants.
Notify Me18 year and older
All sexes
Interventional
Not applicable
Beijing, China
This trial is a prospective multi-center single-arm confirmatory study. A total of 102 subjects will be enrolled in multiple centers nationwide. Subjects who meet the trial requirements, fulfill the inclusion criteria, voluntarily participate in the study, and provide informed consent will undergo mitral edge-to-edge repair using the NovoClasp® transcatheter mitral valve clip system and steerable guide catheter for the treatment of moderate to severe or severe degenerative mitral regurgitation (DMR). Follow-up assessments will be conducted at discharge, as well as at 30 days, 90 days, 180 days, and 360 days postoperatively. The primary endpoint will be the treatment effectiveness rate at 360 days post-surgery. Secondary endpoint measures include treatment effectiveness at other time points, surgical success rate, all-cause mortality, device/procedure-related mortality, incidence of adverse events, and serious adverse event rates. The trial aims to comprehensively assess the safety and efficacy of the NovoClasp® transcatheter mitral valve clip and steerable guide catheter produced by Enlight Medical Technologies (Shanghai) Co., Ltd..
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Subjects must meet all of the following criteria to be eligible for this study.
Exclusion criteria
Subjects meeting any of the following criteria are not eligible for this study.
The experimental device is a class III implanted valve device, which will be used to treat the mitral valve regurgitation via transcatheter edge-to-edge repair.
Other names: transcatheter edge-to-edge repair for mitral valve
Time frame: 1 year
Treatment effectiveness is defined as the success of the procedure with the mitral valve regurgitation sustained at moderate or lower (<=2+) after the surgery, without major adverse events or secondary interventions (interventional or surgical).
Time frame: immediately after procedure
Successful implantation of a single device as intended by the operator, successful retrieval of the delivery system, absence of device migration, dislodgment, embolization, related complications, or other unforeseen incidents.
Time frame: During the perioperative period
Defined as successful completion of the investigational procedure as intended by the operator (implantation of at least 1 study device) and reduction of mitral valve regurgitation to moderate or below (<=2+), without open surgery, major adverse events during the perioperative period, or secondary interventions (interventional or surgical).
Note: Major adverse events include cardiovascular-related deaths, stroke, myocardial infarction, need for renal replacement therapy, severe bleeding (hemoglobin decrease >=3g/dL compared to baseline, or requiring >=3 units of blood transfusion), or organ damage, failure, or death dur to blood loss.
Time frame: 30 days, 180 days
Treatment effectiveness is defined as the success of the procedure with the mitral valve regurgitation sustained at moderate or lower (<=2+) after the surgery, without major adverse events or secondary interventions (interventional or surgical).
Time frame: through study completiong, an average of 1 year.
The NYHA Classification provides nomenclature to describe an overall cardiac appraisal of the status of a patient with heart disease.
Class I: Patients with cardiac disease but without resulting limitation of physical activity.
Class II: patients with cardiac disease resulting in slight limitation of physical activity.
Class III: Patients with cardiac disease resulting in marked limitation of physical activity.
Class IV: Patient with cardiac disease resulting in inability to carry on any physical activity without discomfor.
Time frame: through study completion, an average of 1 year
Time frame: through study completion, an average of 1 year
Time frame: through study completion, an average of 1 year
Time frame: through study completion, an average of 1 year
Time frame: through study completion, an average of 1 year
Enlight Medical Technologies (Shanghai) Co., Ltd
Industry
A Prospective, Multicenter, Single-arm Clinical Study of NovoClasp Transcatheter Mitral Valve Clip and Steerable Guide Catheter for Treating Moderate to Severe and Severe Degenerative Mitral Regurgitation (DMR)
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03433274
Cardiovascular Diseases, Degenerative Mitral Valve Disease
Birmingham, Alabama, United States
View Trial DetailsNCT03706833
Cardiovascular Diseases, Degenerative Mitral Valve Disease
Phoenix, Arizona, United States
View Trial DetailsNCT03674593
Degenerative Mitral Valve Disease
Tomsk, Russia
View Trial DetailsNCT07605715
Degenerative Mitral Valve Disease
Los Angeles, California, United States
View Trial Details