AcrySof® IQ PanOptix™ Presbyopia-Correcting IOL
DeviceTrifocal IOL(near, intermediate, distance) implanted for long-term use over the lifetime of the cataract patient
Other names: Model TFNT00
NCT Number: NCT02691741
The purpose of this study is to clinically evaluate the visual performance of two commercially available presbyopia-correcting Trifocal IOLs.
Looking for future studies?
Notify Me22 year and older
All sexes
Interventional
Not applicable
Subjects will attend a total of 9 visits (6 postoperative) over a 7 month period.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Trifocal IOL(near, intermediate, distance) implanted for long-term use over the lifetime of the cataract patient
Other names: Model TFNT00
Trifocal IOL(near, intermediate, distance) implanted for long-term use over the lifetime of the cataract patient
Other names: Model 839MP
Time frame: Day 120-180 from second eye implantation
VA was tested binocularly (both eyes together) with no refractive correction in place using an early treatment diabetic retinopathy study (ETDRS) chart set at 60 cm. VA was measured in "logarithm of the minimum angle of resolution" (logMAR), with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart. A lower numeric value represents better visual acuity.
Time frame: Day 120-180 from second eye implantation
VA was tested binocularly with no refractive correction in place using an ETDRS chart set at 60 cm. VA was measured in logMAR, with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart. A lower numeric value represents better visual acuity.
Time frame: Day 120-180 from second eye implantation
VA was tested binocularly with no refractive correction in place using an ETDRS chart set at 4 meters. VA was measured in logMAR, with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart. A lower numeric value represents better visual acuity.
Time frame: Day 120-180 from second eye implantation
VA was tested binocularly with no refractive correction in place using an ETDRS chart set at 40 cm. VA was measured in logMAR, with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart. A lower numeric value represents better visual acuity.
Time frame: Day 120-180 from second eye implantation
A defocus curve is created by multiple measurements of one's visual acuity (VA) at different spherical powers. VA was measured in logMAR. A lower logMAR value indicates better visual acuity. No statistical test was performed.
Time frame: Day 120-180 from second eye implantation
Contrast sensitivity (ie, the ability to detect slight changes in luminance before they become indistinguishable) was assessed binocularly in lighted conditions with distance manifest correction in place and uncorrected, with no glare source illumination. Contrast sensitivity was assessed at spatial frequencies of 3, 6, 12, and 18 cycles per degree (CPD) and reported in log units. A higher numeric value represents better contrast sensitivity. No statistical test was performed.
Time frame: Day 120-180 from second eye implantation
Contrast sensitivity (ie, the ability to detect slight changes in luminance before they become indistinguishable) was assessed binocularly in lighted conditions with distance manifest correction in place and uncorrected, with glare source illumination. Contrast sensitivity was assessed at spatial frequencies of 3, 6, 12, and 18 CPDs and reported in log units. A higher numeric value represents better contrast sensitivity. No statistical test was performed.
Time frame: Day 120-180 from second eye implantation
Contrast sensitivity (ie, the ability to detect slight changes in luminance before they become indistinguishable) was assessed binocularly in dim to dark conditions with distance manifest correction in place and uncorrected, with no glare source illumination. Contrast sensitivity was assessed at spatial frequencies of 1.5, 3, 6, and 12 CPDs and reported in log units. A higher numeric value represents better contrast sensitivity. No statistical test was performed.
Time frame: Day 120-180 from second eye implantation
Contrast sensitivity (ie, the ability to detect slight changes in luminance before they become indistinguishable) was assessed binocularly with distance manifest correction in place and uncorrected, with glare source illumination. Contrast sensitivity was assessed at spatial frequencies of 1.5, 3, 6, and 12 CPDs and reported in log units. A higher numeric value represents better contrast sensitivity. No statistical test was performed.
Time frame: Day 120-180 from second eye implantation
At the Month 6 Visit, subjects responded to the question: "Given your current postoperative vision, if you had to do it all over would you have the same lens implanted again?". Responses were reported as a percentage of subjects. No statistical test was performed.
Alcon Research
Industry
Clinical Investigation of Visual Function After Bilateral Implantation of Two Presbyopia-Correcting Trifocal IOLs
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06377514
Cataract, Cataracts
Bakersfield, California, United States
View Trial DetailsNCT05575063
Cataract, Cataracts
Bakersfield, California, United States
View Trial DetailsNCT02535819
Cataract, Cataracts
Metz, France
View Trial DetailsNCT06250322
Cataract, Cataracts
Chatswood, New South Wales, Australia
View Trial Details