Ahmad Fayez Ahmad
Latakia, Syria
Location status: Recruiting
NCT Number: NCT07654647
This clinical study aims to evaluate the effectiveness of patient-specific 3D-printed titanium facial implants in the reconstruction and aesthetic correction of facial defects. The study will include patients presenting with congenital, traumatic, or post-surgical facial deformities requiring reconstructive intervention.
Eligible participants will undergo preoperative clinical assessment and radiological imaging to design customized implants using computer-aided design (CAD) and 3D printing technology. The implants will be fabricated from medical-grade titanium and surgically placed according to standardized maxillofacial reconstructive protocols.
Postoperative follow-up will assess functional outcomes, implant stability, complication rates, and aesthetic improvement over a defined observation period. Outcome evaluation will include clinical examination and patient-reported satisfaction measures.
The objective of this study is to determine whether patient-specific 3D-printed titanium implants provide reliable functional restoration and improved aesthetic outcomes in facial reconstruction compared to conventional reconstructive techniques.
Interested in participating?
Request Info18 year–60 year
All sexes
Interventional
Not applicable
Latakia, Syria
Location status: Recruiting
Background:
Facial bone defects and contour deformities may result from congenital anomalies, trauma, tumor resection, cystic lesions, or developmental deficiencies. Conventional reconstructive techniques often rely on standard implants or intraoperative modification of grafts, which may not provide optimal anatomical adaptation or aesthetic outcomes.
Recent advances in three-dimensional (3D) imaging, computer-aided design (CAD), and additive manufacturing technologies have enabled the production of patient-specific titanium implants tailored to the unique anatomy of individual patients. These implants may improve surgical precision, reduce operative time, enhance facial symmetry, and provide more predictable functional and aesthetic outcomes.
Objective:
This clinical study aims to evaluate the effectiveness, safety, and clinical performance of patient-specific 3D-printed titanium facial implants in the reconstruction and aesthetic correction of facial defects.
Methods:
Eligible adult patients presenting with facial bone defects, facial asymmetry, congenital deformities, post-traumatic defects, or aesthetic indications requiring customized facial augmentation will undergo preoperative imaging using computed tomography (CT). Patient-specific titanium implants will be designed using computer-aided design software and manufactured using 3D-printing technology.
Clinical evaluation will include assessment of implant fit accuracy, facial symmetry, aesthetic outcomes, postoperative complications, patient satisfaction, and overall treatment success. Follow-up assessments will be performed at regular intervals for up to 12 months after surgery.
Expected Outcomes:
The study is expected to demonstrate that patient-specific 3D-printed titanium implants provide accurate anatomical reconstruction, improved facial aesthetics, high patient satisfaction, and acceptable safety profiles when used for facial reconstruction and contour correction.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Patient-specific 3D-printed titanium implants will be used for reconstruction of facial bone defects and correction of facial deformities. Each implant will be individually designed based on high-resolution computed tomography (CT) imaging and three-dimensional virtual surgical planning (VSP) using computer-aided design (CAD) software to accurately match the patient's anatomical defect.
The implants will be manufactured from medical-grade titanium alloy (Ti6Al4V) using selective laser melting (SLM) additive manufacturing technology. Post-processing will include surface finishing and sterilization prior to surgical use.
Surgical placement will be performed under general anesthesia following standard maxillofacial surgical protocols. The customized implants will be fixed to the native bone using titanium fixation screws when required to restore facial contour, structural support, and symmetry.
Postoperative follow-up will include clinical and radiological assessment using CT imaging t
Time frame: From surgery up to 6 months postoperatively
Assessment of postoperative complications following reconstruction with patient-specific 3D-printed titanium implants. Complications include infection, implant exposure, implant failure, or the need for revision surgery. Each patient will be assigned a binary score: 0 = no postoperative complication and 1 = presence of one or more postoperative complications. The outcome will be evaluated and recorded by the treating surgeon during the follow-up period. Higher values indicate a greater complication rate.
Time frame: Immediately after laser-based 3D printing of the implant and before surgical implantation.
Assessment of the geometric accuracy of the patient-specific 3D-printed titanium implant by performing three-dimensional scanning of the manufactured implant and comparing it with the original digital design using 3D deviation analysis software. Accuracy will be quantified as the root mean square (RMS) deviation between the scanned implant and the planned digital model. Lower deviation values indicate higher manufacturing accuracy.
Time frame: 3 months after surgery
Assessment of facial symmetry following reconstruction using a standardized 5-point facial symmetry scale evaluated by an independent plastic surgeon. Scores range from 1 (severe asymmetry) to 5 (excellent symmetry). Higher scores indicate better aesthetic outcomes.
Time frame: During surgery
Assessment of the total duration of the surgical procedure, measured from skin incision to wound closure and recorded in minutes. Operative time will be compared with historical data from conventional reconstruction techniques. Lower values indicate greater surgical efficiency.
Time frame: 3 months after surgery
Assessment of patient satisfaction with the reconstructive outcome using a 10-point Visual Analog Scale (VAS). The scale ranges from 0 to 10, where 0 indicates complete dissatisfaction and 10 indicates complete satisfaction. Higher scores indicate greater patient satisfaction.
Contact information is provided by the study sponsor or research team.
Latakia University
Other
Evaluation of the Effectiveness of Patient-Specific 3D-Printed Titanium Facial Implants in the Reconstruction and Aesthetic Correction of Facial Defects: A Clinical Study
Acronym: 3DFACE
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04931056
Acrofacial dysostosis, Nager type, Bone Diseases
Salta, Argentina
View Trial DetailsNCT02224677
Bone Diseases, Bone Diseases, Developmental
Los Angeles, California, United States
View Trial DetailsNCT04351893
Bone Diseases, Bone Diseases, Developmental
Los Angeles, California, United States
View Trial DetailsNCT03869021
Bone Diseases, Bone Diseases, Developmental
Cairo, Egypt
View Trial Details