The Stomatologic Hospital, School of Medicine, Zhejiang University
Hangzhou, Zhejiang, 310003, China
NCT Number: NCT06022042
In clinical implant treatment, the healing abutment or temporary abutment needs to be removed or replaced multiple times after implant insertion and before prosthesis restoration. During this process, the friction between connective tissue around the implant cannot be avoided. Different from natural periodontal tissue, soft tissue around the implant lacks the periodontal ligament barrier and periodontal ligament blood supply, and is more likely to be damaged during repeated wearing. The integrity, health and stability of the peri-implant connective tissue is crucial to the implant osseointegratio. Through randomized controlled trials and meta-analysis, Marco Tallarico et al found that repeated removal of one-stage abutments can significantly increase bone resorption.
Based on this situation, the design of implant neck and abutment, especially the design concept of smooth collar, has attracted widespread attention. The design of smooth collars with different heights can isolate the mechanical damage of the abutment to the connective tissue around the implant to different degrees. Among them, the On1 two-stage abutment has a smooth collar with a height of 1.75-2.5mm, and the Nobel implants have a smooth neck design ranging from 0-0.75mm to protect the connective tissue around the implant. Through a systematic review and meta-analysis, Qing-qing Wang et al concludes that direct mechanical stimulation from the abutment has long-term adverse effects on peri-implant connective tissue and bone tissue. However, whether the On1 two-stage abutment has a positive effect on the stabilization of the peri-implant soft tissue and bone tissue remains to be studied.
At the same time, the relative height of the smooth collar increased by the On1 abutment in the implants with different neck designs varies to some extent, and further research is still needed to provide evidence about the effect of the On1 abutment on the tissue surrounding the implants with different neck designs. In conclusion, this study took On1 two-stage abutment and traditional one-stage abutment as the research objects to compare and evaluate the clinical effects of the two in different implant neck design.
This study is active but is not currently recruiting participants.
Notify Me18 year–70 year
All sexes
Interventional
Not applicable
Hangzhou, Zhejiang, 310003, China
Research purpose To compare the clinical effects of On1 two-stage abutment and one-stage abutment in implants with different neck design.
Research Design and Methods
Measures to control bias:
Inclusion criteria
(1) aged 18 years and above, 70 years old and below; (2) Single crown restoration after implantation (3) Subjects signed written informed consent; (4) The general health status is good and adhered to Good oral hygiene conditions; (5) no infection and extraction residues at the implant site; (6) sufficient keratinized gingiva on the cheek and tongue; (7) good and stable occlusal relationship; (8) the occlusal gap is higher than 4mm; (9) No other additional operations are planned to perform.
Exclusion criteria
(1) contraindications to general implant surgery; (2) uncontrolled diabetes mellitus; (3) any signs of immunosuppression; (4) previous head and neck radiation therapy; (5) past or current use of bisphosphonates treatment; (6) substance abuse; (7) nocturnal teeth grinding; (8) signs of periodontitis; (9) smoking more than 10 cigarettes per day; (10) poor oral hygiene; (11) mental disorders; (12) inability to complete follow-up; (13) History of night grinding.
Withdrawal criteria:
(1) abnormal vital organ function (2) poor compliance (3) serious adverse reactions (4) poor efficacy (5) intolerance of adverse reactions (6) willing to take other treatment methods or withdraw without any reason.
Criteria for termination of the trial: ① There are serious adverse events, and the adverse events are likely to be related to the intervention in the trial; ② External information (such as other high-quality research or evidence) proves that the intervention is ineffective or effective, and the current clinical trial is not necessary to continue, ③ According to the planned interim analysis to achieve the expected difference in efficacy, if it has been observed that the intervention program of the experimental group is significantly better than that of the control group.
Statistical analysis: The homogeneity of variance is planned to be tested within groups, the outcome indicators of different groups are planned to be analyzed by variance between groups, and further correlation analysis is planned to perform on indicators with significant differences.
Secondary observation indicators: mesial and distal gingival papilla and buccal mucosa recession; abutment buccal keratinized gingiva width; probing bleeding index; Red aesthetic index, subject self-satisfaction, and time to subsidence of mucous membrane blushing when wearing teeth.
Sample Size Calculation
The sample size of this study was estimated by G*Power software. To satisfy statistical significance, set the conditions as t tests, α=0.05, 1-β=0.9. Referring to studies of the same type [3], the effect size ES f=0.8 was set, and the minimum sample size of each group was calculated to be 28. Based on the standard of 5% loss to follow-up rate, the number of subjects recruited in each group of this study is set to be 30. The grouping design and sample size are as follows:
group design sample size On1 abutment + Nobel PMC implant set, 30 On1 Abutment + Nobel PCC Implant Set 30 On1 Abutment + Nobel CC Implant Set 30 One-Stage Abutment + Nobel PMC Implant Set 30 One-Stage Abutment + Nobel PCC Implant Set 30 One-Stage Abutment + Nobel CC Implant Set 30 Data management and confidentiality
Informed consent This study will be conducted by the research doctor in the Oral Implantation Center of Zhejiang University Affiliated Stomatology Hospital, and the subjects will be informed and informed consent will be obtained before surgery. The informed consent process conforms to the principles of complete notification, full understanding, and independent choice; the expression of informed consent is easy to understand and conforms to the level of understanding of the subject group.
This study does not involve vulnerable groups. All subjects will sign the informed consent form by themselves.
Adverse event reporting This study did not include measures and interventions other than routine clinical treatment, and had no other adverse effects on the subjects.
In the event of an adverse event, we will report it as follows:
Various adverse events: Take timely measures to deal with them and record them in the case report form.
Serious adverse events (SAE): take measures to deal with them timely, and record in a case report form, stop the trial at the decision of the investigator, immediately report to the ethics committee, drug clinical trial institutions and sponsors, and report to national and provincial food within 24 hours Drug Administration.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
the On1 two-stage abutment has a smooth collar with a height of 1.75-2.5mm, and the Nobel implants have a smooth neck design ranging from 0-0.75mm to protect the connective tissue around the implant.
Other names: Nobel PMC implant, Nobel CC implant, Nobel PCC implant
Time frame: 1-7 years
Time frame: 1-7 years
The distance between the level of implant shoulder and the alveolar ridge.
Time frame: 1-7 years
Time frame: 1-7 years
mesial and distal gingival papilla and buccal mucosa recession
Time frame: 1-7 years
abutment buccal keratinized gingiva width
Time frame: 1-7 years
probing bleeding index
Time frame: within 30 minutes
Patients were also assessed by visual anlog scale (VAS) for The degree of pain and self-satisfaction of wearing the teeth was assessed using the visual anlog scale (VAS) [11]. A 10 cm long scale with the leftmost end scored as 0 means no pain (unsatisfactory); the rightmost end scored as 0 means no pain (unsatisfactory); the rightmost end scored as 0 means no pain (unsatisfactory); and the rightmost end scored as 0 means no pain (unsatisfactory). (unsatisfactory); the right-most end of the scale was scored as 10, indicating severe pain (extremely satisfactory). The patient marks the scale according to his/her own feelings. The patient marks the scale according to his/her own feelings, with 1cm representing 1 point, and the indicated position is converted into the final score.
Time frame: within 30 minutes
time to subsidence of mucous membrane blushing when wearing teeth
Yi Zhou
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06020040
Implant Site Reaction
Hangzhou, Zhejiang, China
View Trial DetailsNCT06776640
Implant Site Reaction
Nantes, France
View Trial DetailsNCT06043037
Dental Implant Failed, Implant Site Reaction
Kafr ash Shaykh, Kafrelsheikh, Egypt
View Trial DetailsNCT06783595
Implant Site Reaction, Mouth Diseases
Loma Linda, California, United States
View Trial Details