The purpose of this study is to develop a clinical algorithmic-based evaluation and treatment approach for C-Brace for use by persons with hemiparesis or hemiplegia due to stroke.
Looking for future studies?
Notify Me18 year–65 year
All sexes
Interventional
Not applicable
Houston, Texas, 77030, United States
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
C-Brace is a micro-computer controlled brace that is worn on the leg to assist with walking.
Time frame: week 5
During the 10 Meter Walk Test (10MWT), infrared light emitting diode markers will be attached to bilateral lower extremities. The marker data will be recorded using the Northern Digital Inc (NDI) Optotrak Certus motion capture system. Marker data will be processed using custom Matlab program to determine lower extremity joint excursion. Joint excursion is the range of motion of a particular joint, and the range of motion is reported in degrees. After stroke, one side of the body is affected, and joint excursion for various joint angles (of hip, knee, and ankle) are reported for both sides of the body (affected side of body and unaffected side of body).
Time frame: week 9
During the 10 Meter Walk Test (10MWT), infrared light emitting diode markers will be attached to bilateral lower extremities. The marker data will be recorded using the NDI Optotrak Certus motion capture system. Marker data will be processed using custom Matlab program to determine lower extremity joint excursion. Joint excursion is the range of motion of a particular joint, and the range of motion is reported in degrees. After stroke, one side of the body is affected, and joint excursion for various joint angles (of hip, knee, and ankle) are reported for both sides of the body (affected side of body and unaffected side of body).
Time frame: week 5
Bipolar surface electrodes will be placed on the bilateral major leg muscles to record electromyography (1000Hz, Motion Labs 16-Channel EMG System). The EMG amplitude (in volts) will be calculated over the whole gait cycle during the 10 Meter Walk Test (10MWT), in which the participant walks 10 meters. After stroke, one side of the body is affected, and data for various muscles are reported for both sides of the body (affected side of body and unaffected side of body).
Time frame: week 9
Bipolar surface electrodes will be placed on the bilateral major leg muscles to record electromyography (1000Hz, Motion Labs 16-Channel EMG System). The EMG amplitude (in volts) will be calculated over the whole gait cycle during the 10 Meter Walk Test (10MWT), in which the participant walks 10 meters. After stroke, one side of the body is affected, and data for various muscles are reported for both sides of the body (affected side of body and unaffected side of body).
Time frame: week 5
Change in metabolic expenditure during walking will be indicated by energy expenditure. Energy Expenditure will be measured by the K4 b2 Cosmed as follows: Oxygen cost will be calculated from oxygen consumption as the product of gait speed and body weight. Oxygen consumption will be collected on a breath-by-breath basis measured by a portable metabolic system (K4 b2 Cosmed). Prior to the testing, the system will be calibrated using room air and reference gas mixture. During the testing, the subject will wear a face mask and a heart rate monitor at all times and will be asked to breathe normally.
Time frame: week 9
Change in metabolic expenditure during walking will be indicated by energy expenditure. Energy Expenditure will be measured by the K4 b2 Cosmed as follows: Oxygen cost will be calculated from oxygen consumption as the product of gait speed and body weight. Oxygen consumption will be collected on a breath-by-breath basis measured by a portable metabolic system (K4 b2 Cosmed). Prior to the testing, the system will be calibrated using room air and reference gas mixture. During the testing, the subject will wear a face mask and a heart rate monitor at all times and will be asked to breathe normally.
Time frame: week 0
Assesses mobility, balance, walking ability, and fall risk in older adults. The test measures the time it takes the subject to perform a sit to stand from a chair with arms, walk to a mark on the ground 10 feet away and return to the seated position in the chair with arms. This test has been used in assessing stroke recovery with high reliability and validity.
Time frame: week 5
Assesses mobility, balance, walking ability, and fall risk in older adults. The test measures the time it takes the subject to perform a sit to stand from a chair with arms, walk to a mark on the ground 10 feet away and return to the seated position in the chair with arms. This test has been used in assessing stroke recovery with high reliability and validity.
Time frame: week 9
Assesses mobility, balance, walking ability, and fall risk in older adults. The test measures the time it takes the subject to perform a sit to stand from a chair with arms, walk to a mark on the ground 10 feet away and return to the seated position in the chair with arms. This test has been used in assessing stroke recovery with high reliability and validity.
Time frame: week 0
Mini Mental State Examination provides information about orientation, attention, learning, calculation, delayed recall, and construction. Several studies report acceptable validity of MMSE as a screening instrument and its relationship to functional outcome in stroke population. Total score ranges from 0 to 30, with a higher score indicating a better outcome.
Time frame: week 9
Mini Mental State Examination provides information about orientation, attention, learning, calculation, delayed recall, and construction. Several studies report acceptable validity of MMSE as a screening instrument and its relationship to functional outcome in stroke population. Total score ranges from 0 to 30, with a higher score indicating a better outcome.
Time frame: week 0, week 9
Muscle strength will be measured and quantified by using dynamometers on major bilateral lower limb muscles such as hip flexors.
Time frame: week 0, week 9
Muscle strength will be measured and quantified by using dynamometers on major bilateral lower limb muscles such as hip extensors.
Time frame: week 0, week 9
Muscle strength will be measured and quantified by using dynamometers on major bilateral lower limb muscles such as hip abductors.
Time frame: week 0, week 9
Muscle strength will be measured and quantified by using dynamometers on major bilateral lower limb muscles such as hip adductors.
Time frame: week 0, week 9
Muscle strength will be measured and quantified by using dynamometers on major bilateral lower limb muscles such as knee flexors.
Time frame: week 0, week 9
Muscle strength will be measured and quantified by using dynamometers on major bilateral lower limb muscles such as knee extensors.
Time frame: week 0, week 9
Muscle strength will be measured and quantified by using dynamometers on major bilateral lower limb muscles such as ankle dorsiflexors.
Time frame: week 0, week 9
Muscle strength will be measured and quantified by using dynamometers on major bilateral lower limb muscles such as ankle plantarflexors.
Time frame: week 0
Range of motion will be measured on bilateral hip using goniometry (goniometry is the use of a device called a goniometer to measure range of motion of a joint in degrees). After stroke, one side of the body is affected. For each participant, the range of motion of their affected hip will be measured and also the range of motion of their other hip (the unaffected hip) will be measured [it is possible that a participant will have a range of motion within normal limits on both hip sides (affected hip and unaffected hip)].
Time frame: week 9
Range of motion will be measured on bilateral hip using goniometry (goniometry is the use of a device called a goniometer to measure range of motion of a joint in degrees). After stroke, one side of the body is affected. For each participant, the range of motion of their affected hip will be measured and also the range of motion of their other hip (the unaffected hip) will be measured [it is possible that a participant will have a range of motion within normal limits on both hip sides (affected hip and unaffected hip)].
Time frame: week 0
Range of motion will be measured on knee joints using goniometry (goniometry is the use of a device called a goniometer to measure range of motion of a joint in degrees). After stroke, one side of the body is affected. For each participant, the range of motion of their affected knee will be measured and also the range of motion of their other knee (the unaffected knee) will be measured [it is possible that a participant will have a range of motion within normal limits for both knees (affected knee and unaffected knee)].
Time frame: week 9
Range of motion will be measured on knee joints using goniometry (goniometry is the use of a device called a goniometer to measure range of motion of a joint in degrees). After stroke, one side of the body is affected. For each participant, the range of motion of their affected knee will be measured and also the range of motion of their other knee (the unaffected knee) will be measured [it is possible that a participant will have a range of motion within normal limits for both knees (affected knee and unaffected knee)].
Time frame: week 0
Range of motion will be measured on ankle joints using goniometry (goniometry is the use of a device called a goniometer to measure range of motion of a joint in degrees). After stroke, one side of the body is affected. For each participant, the range of motion of their affected ankle will be measured and also the range of motion of their other ankle (the unaffected ankle) will be measured [it is possible that a participant will have a range of motion within normal limits for both ankles (affected ankle and unaffected ankle)].
Time frame: week 9
Range of motion will be measured on ankle joints using goniometry (goniometry is the use of a device called a goniometer to measure range of motion of a joint in degrees). After stroke, one side of the body is affected. For each participant, the range of motion of their affected ankle will be measured and also the range of motion of their other ankle (the unaffected ankle) will be measured [it is possible that a participant will have a range of motion within normal limits for both ankles (affected ankle and unaffected ankle)].
Time frame: week 0
The Fugl-Meyer Assessment evaluates and measures recovery of movement in individual post stroke. The Fugl-Meyer has been used in both clinical and research settings and is one of the most widely used quantitative measures of motor impairment. It uses an ordinal scale for scoring of 17 items for the lower limb component and 7 items on the balance component, for a total of 24 items. Each of the 24 items is scored as 0 (cannot perform), 1 (can perform partially), or 2 (can perform fully), with a total score ranging from 0 to 48, with a higher score indicating less impairment.
Time frame: week 9
The Fugl-Meyer Assessment evaluates and measures recovery of movement in individual post stroke. The Fugl-Meyer has been used in both clinical and research settings and is one of the most widely used quantitative measures of motor impairment. It uses an ordinal scale for scoring of 17 items for the lower limb component and 7 items on the balance component, for a total of 24 items. Each of the 24 items is scored as 0 (cannot perform), 1 (can perform partially), or 2 (can perform fully), with a total score ranging from 0 to 48, with a higher score indicating less impairment.
Time frame: week 0
This test measures spasticity in patients with lesions of the Central Nervous System by testing resistance to passive movement about a joint with varying degrees of velocity. Scores range from 0-4, with 0 indicating normal muscle tone and 4 indicating very high spasticity. The investigators will measure spasticity in lower limbs.
Time frame: week 9
This test measures spasticity in patients with lesions of the Central Nervous System by testing resistance to passive movement about a joint with varying degrees of velocity. Scores range from 0-4, with 0 indicating normal muscle tone and 4 indicating very high spasticity. The investigators will measure spasticity in lower limbs.
Time frame: week 0
A 14-item objective measure designed to assess static balance and fall risk in adult populations, with a total score range of 0 to 56 (higher scores represent better functional outcome). This test has been widely used to measure functional recovery in stroke patients with high reliability.
Time frame: week 9
A 14-item objective measure designed to assess static balance and fall risk in adult populations, with a total score range of 0 to 56 (higher scores represent better functional outcome). This test has been widely used to measure functional recovery in stroke patients with high reliability.
Time frame: week 0
Measure of gait speed. Subjects will walk a total of 14 meters at their preferred walking speed and at a fast pace. The test measures the time it takes the subject to complete the middle 10 meters of the walk.
Time frame: week 5
Measure of gait speed. Subjects will walk a total of 14 meters at their preferred walking speed and at a fast pace. The test measures the time it takes the subject to complete the middle 10 meters of the walk.
Time frame: week 9
Measure of gait speed. Subjects will walk a total of 14 meters at their preferred walking speed and at a fast pace. The test measures the time it takes the subject to complete the middle 10 meters of the walk.
Time frame: week 0
The participant will perform the 6MWT, in which the participant will walk as far as possible in six minutes. During the 6MWT, the peak volume of oxygen consumed per minute (peak VO₂) will be measured by a portable metabolic system. Data are reported as peak volume of oxygen (in milliliters) consumed per kilogram bodyweight per minute per meter walked [milliliters/kilogram/minute/meter (mL/kg/min/m)].
Time frame: week 5
The participant will perform the 6MWT, in which the participant will walk as far as possible in six minutes. During the 6MWT, the peak volume of oxygen consumed per minute (peak VO₂) will be will be measured by a portable metabolic system. Data are reported as peak volume of oxygen (in milliliters) consumed per kilogram bodyweight per minute per meter walked [milliliters/kilogram/minute/meter (mL/kg/min/m)].
Time frame: week 9
The participant will perform the 6MWT, in which the participant will walk as far as possible in six minutes. During the 6MWT, the peak volume of oxygen consumed per minute (peak VO₂) will be will be measured by a portable metabolic system. Data are reported as peak volume of oxygen (in milliliters) consumed per kilogram bodyweight per minute per meter walked [milliliters/kilogram/minute/meter (mL/kg/min/m)].
The University of Texas Health Science Center, Houston
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07014696
Hand Functionality, Hemiplegia
Istanbul, Bahçeşir, Turkey (Türkiye)
View Trial DetailsNCT06837038
Basal Ganglia Diseases, Brain Diseases
Beijing, Beijing Municipality, China
View Trial Details