Characterization of RadiOlabeled Tracer Uptake Pattern in Noninfected Transcatheter Aortic Valves.

Therefore, the objective of the study is to characterize the pattern of radiolabeled tracer (18F-FDG) uptake in noninfected transcatheter heart valves in early follow-up after transcatheter aortic valve replacement (TAVR).

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Centre de recherche de L'Institut universitaire de cardiologie et de pneumologie de Québec

Québec, Quebec, G1V 4G5, Canada

About this study

Diagnostic accuracy of Infective endocarditis (IE) is commonly challenging. Current clinical guidelines recommend the use of the modified Duke criteria, based on clinical, echocardiographic and biological findings, as well as the results of blood cultures and serologies. Advances in imaging techniques have resulted in an improvement in the identification of endocardial involvements and extracardiac complications of IE. Thus, recent works have demonstrated that 18F-FDG PET/CT and radiolabeled leucocyte SPECT/CT may improve the detection of silent endocardial lesions. The sites of radiotracer accumulation show regions of a high metabolic activity due to an inflammation or infection process. It is well known that, in surgical prosthetic valves, a mild radiotracer uptake in the perivalvular area may occur in the absence of infection and could therefore be considered as a normal pattern, particularly early after valve replacement. However, evidence of this phenomenon is lacking regarding transcatheter heart valves and the factors used to distinguish between normal and abnormal patterns of radiolabeled tracer are not standardized. The hypothesis is that patients undergoing transcatheter aortic valve replacement (TAVR) show a radiolabeled tracer (18F-FDG) uptake around the prosthesis despite the absence of IE. Moreover, the uptake pattern might vary between different platforms.

Therefore, the objective of the study is to characterize the pattern of radiolabeled tracer uptake in noninfected transcatheter heart valves in early follow-up after TAVR.

This will be a pilot study including 30 patients after TAVR procedure.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients >18-year-old undergoing TAVR procedure with Edwards Sapien 3 and Core Valve Evolut R devices.
  • Informed written consent

Exclusion criteria

  • Inability to provide signed informed consent.
  • Patients with definitive or possible IE according to modified Duke criteria and current clinical guidelines for the management of IE.
  • Any contraindication for 18F-FDG PET/CT.
  • Any condition making it unlikely the patient will be able to complete the protocol procedures and follow-up visits.

Treatment and study plan

18F-FDG PET/CT

Radiation

18F-FDG PET/CT and blood cultures will be performed at 3-month follow-up after TAVR Patients with positive 18F-FDG PET/CT (moderate or intense radiolabeled tracer uptake) will be scheduled for a second 18F-FDG PET/CT at 6-month follow-up.

Primary outcomes

  1. Radiolabeled tracer uptake grade (intense, moderate, mild or absent) in the prosthetic and periprosthetic areas.

    Time frame: 3 months after TAVR

    Visual analysis grading the radiolabeled tracer molecules uptake in the prosthetic and periprosthetic areas as intense, moderate, mild or absent. This visual analysis will be defined whether the PET/CT was positive (intense/moderate) or negative (mild/absent).

Secondary outcomes

  1. Maximal standardized uptake value (SUVmax) using an average of 3 measurements from 3 volumes of interest (5mm3) introduced in the prosthetic region at equal distances from each other.

    Time frame: 3 months after TAVR

    The intensity of the radiolabeled tracer uptake will be determined by measuring the maximal standardized uptake value (SUVmax)), which is obtained by normalizing the tissue concentration of the radiolabeled tracer activity and the patient's weight. SUVmax will be calculated using an average of 3 measurements from 3 volumes of interest (5mm3) introduced in the prosthetic region at equal distances from each other. The prosthetic valve-to-background ratio will be calculated by dividing the prosthetic valve SUV max by the atrial blood SUVmax.

  2. Differences in radiolabeled tracer uptake grade in the prosthetic and periprosthetic areas between the Edwards valve versus the CoreValve valve.

    Time frame: 3 months after TAVR

    Differences in radiolabeled tracer uptake pattern with different valves: Edwards THV vs CoreValve THV

  3. Correlation between radiolabeled tracer uptake grade and time from TAVR

    Time frame: 3 months after TAVR

    Relationship between radiolabeled tracer uptake and time from the procedure

Sponsors and collaborators

Lead sponsor

Centre de Recherche de l'Institut Universitaire de Cardiologie et de Pneumologie de Quebec

Other

Registry information

Official study title

Characterization of Radiolabeled Tracer Uptake Pattern in Noninfected Transcatheter Aortic Valves. The COUNT Study. A Prospective, Observational Study.

Acronym: COUNT

Important dates

Study start
2018
Primary completion
2022
Study completion
2025
First posted
Sep 25, 2018
Registry last updated
Mar 24, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.