Marmara University Hospital
Istanbul, Turkey (Türkiye)
NCT Number: NCT06087250
Carotid blood flow and corrected carotid flow time (Carotid Flow Time (FTc)) provide information about left ventricular preload and inversely correlate with systemic vascular resistance. The reliability in assessing fluid responsiveness has been demonstrated in studies involving invasive cardiac output measurements. In the elderly patient population where arterial elasticity can be compromised, there is no existing data in literature that determines the reliability and predictive value of FTc after general anesthesia induction.
Looking for future studies?
Notify Me65 year–100 year
All sexes
Observational
Istanbul, Turkey (Türkiye)
Doppler ultrasound of the common carotid artery has begun to be used as a potential non-invasive tool for assessing hemodynamic status. Its non-invasive nature, ability to be applied independently of the patient's position, ease of application due to the superficial location of the carotid artery, and resistance to intrathoracic pressure changes are among its advantages. Carotid blood flow and corrected carotid flow time (Carotid Flow Time (FTc)) provide information about left ventricular preload and inversely correlate with systemic vascular resistance. Additionally, the velocity time integral (VTI) measuring blood flow through the carotid artery during systole, when multiplied by the cross-sectional area of the carotid artery, allows for the determination of flow within the carotid artery. The reliability in assessing fluid responsiveness has been demonstrated in studies involving invasive cardiac output measurements. In the elderly patient population where arterial elasticity can be compromised, there is no existing data in literature that determines the reliability and predictive value of FTc after general anesthesia induction.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: 1 hour
the ability ofc FT to predict fluid responsiveness
Time frame: 1 hour
the cutt-of value of cFT to predict fluid responsiveness
Marmara University
Other
Reliability of Carotid Artery Corrected Flow Time Predicting Fluid Responsiveness in Geriatric Patients.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04186416
Fluid Responsiveness, Hemorrhage
Paris, France
View Trial DetailsNCT07245485
Corrected Carotid Flow Time, Fluid Responsiveness
Ankara, Çankaya, Turkey (Türkiye)
View Trial DetailsNCT06188039
Fluid Responsiveness, Surgery
Opole, Poland
View Trial DetailsNCT04914455
Cardiovascular Diseases, Cardiovascular Surgery
Lille, NORD, France
View Trial Details