Sunnybrook Health Sciences Centre
Toronto, Ontario, M4N 3M5, Canada
Location status: Recruiting
Location contact
Jeffrey A Fialkov, MD, MSc., FRCSC
PRINCIPAL_INVESTIGATOR
Meghan Ryan
CONTACT
NCT Number: NCT06600854
This study aims to evaluate the safety, effectiveness, and usability of BoneTape, an innovative medical device designed to fix facial bone fractures, specifically in the zygomaticomaxillary (midface) region. Zygomaticomaxillary fractures, often caused by trauma like car accidents or falls, require surgery to align and stabilize the bones for proper healing. Traditional methods use metal plates and screws, which can be complicated to install, over-engineered for the area, and may lead to complications, requiring additional surgeries.
BoneTape is a new, resorbable (biodegradable) device that offers a simpler, potentially safer alternative. Unlike traditional metal hardware, BoneTape is a flexible, thin plate that can be easily cut to the required shape during surgery and applied directly to the bone using a special tool that anchors it without needing to drill or screw holes. This process significantly simplifies the surgical procedure, reduces the time needed for fixation, and avoids complications associated with drilling into healthy bone tissue.
Study Objectives:
Feasibility: Determine if BoneTape can be successfully used to stabilize midfacial fractures.
Effectiveness: Assess the ability of BoneTape to help bones heal properly without additional complications.
Safety: Monitor and evaluate any adverse events related to the use of BoneTape.
Study Design:
The study is designed as a single-arm, cohort study.
Participants will undergo baseline pre-operative assessments, including clinical exams, CT scans, and pain questionnaires. BoneTape will be applied during surgery, and post-operative assessments will take place within 24 hours. Follow-up visits will occur at 1 week, 6 weeks, 24 weeks, and 12 months to monitor the healing process, assess pain levels, and check for any adverse events.
Eligibility Criteria:
Inclusion:
Adults with a unilateral, non-comminuted (not broken into multiple pieces) zygomaticomaxillary fracture requiring surgery.
Must be skeletally mature, able and willing to attend follow-up visits, and provide informed consent.
Exclusion:
Patients with critically sized bone defects, fractures requiring orbital floor surgery, pregnancy, certain medical conditions impairing bone healing, or those unwilling or unable to follow the study procedures.
Study Duration:
The total study duration is expected to be 21-24 months, including the 12-month follow-up period for each participant.
Outcome Measures:
The primary outcomes include the feasibility of the procedure (successful use of BoneTape without additional hardware), early effectiveness (bone healing and stability at 6 and 24 weeks), and safety (rate and type of adverse events up to 24 weeks). Secondary outcomes will assess long-term safety and effectiveness at 12 months, patient-reported outcomes on pain, and physician feedback on device usability.
This study is a critical step in evaluating BoneTape as a potential alternative to current facial bone fixation methods, potentially improving surgical outcomes and patient quality of life by reducing the complexity of procedures and minimizing the need for additional surgeries.
Interested in participating?
Request InfoAll sexes
Interventional
Not applicable
Toronto, Ontario, M4N 3M5, Canada
Location status: Recruiting
Jeffrey A Fialkov, MD, MSc., FRCSC
PRINCIPAL_INVESTIGATOR
Meghan Ryan
CONTACT
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Patients who meet all of the following criteria will be eligible for inclusion in the study:
Exclusion criteria
Patients who meet any of the following criteria will be excluded from the study:
BoneTape is a craniofacial fracture repair device intended for use in the fixation of non-load-bearing bones of the craniofacial and midfacial skeleton. It can be used in skeletally mature individuals but is not intended for use in the mandible and/or full load bearing procedures. It is composed of: 1) BoneTape implant ("device"), and 2) BoneTape applicator ("applicator").
Time frame: Intervention
Procedure success in target population.
Time frame: Intervention to 24-weeks post-op
Clinical and radiographic bone union
Time frame: Intervention to 24-weeks post-op
Rate of adverse events
Time frame: Intervention to 12-months post-op
Rate of adverse events and clinical examination
Time frame: Baseline to 12 months post-op
Pain scored using Numerical rating Scale
Time frame: Intervention
Surgeon will complete a specific questionnaire to rate and provide feedback
Time frame: Baseline to 12 months post-op
Time frame: Intervention
Contact information is provided by the study sponsor or research team.
Cohesys Inc.
Industry
Clinical Feasibility of BoneTape: a Novel Approach for Zygomaticomaxillary Fracture Fixation
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07608380
Craniocerebral Trauma, Facial Injuries
Cairo, Egypt
View Trial DetailsNCT06850857
Craniocerebral Trauma, Facial Injuries
Sacramento, California, United States
View Trial DetailsNCT07280533
Craniocerebral Trauma, Facial Bone Fracture
Cairo, Egypt
View Trial DetailsNCT07103187
Craniocerebral Trauma, Facial Injuries
Tanta, Algharbiah, Egypt
View Trial Details