Inselspital, Bern University Hospital
Bern, 3010, Switzerland
NCT Number: NCT03742830
Nowadays, the gold standard for difficult airway management is awake intubation with a flexible fiberscope. Alternatively, when the flexible fiberscope is unable to facilitate tracheal intubation, rigid stylets may be used. One newly developed rigid video stylet also features a flexible tip (C-MAC VS, Karl Storz AG, 78532 Tuttlingen, Germany). The distal angular offset of the C-MAC VS, in which the camera and light sources are integrated, can be aligned (up to 60°) to the patient's anatomical structures to facilitate intubation.
Although awake intubation is less comfortable for the patient and more time consuming, there are several reasons why this is often performed. The investigators plan a prospective observational with 36 participants using the C-MAC VS on adult patients with indication for awake oral intubation.
To ease the placement of the tube (intubation), the investigators will use local anesthesia of the mucosa in the mouth, pharynx and larynx.
The main purpose of the study is to prove the feasibility of successful awake intubation with the C-MAC VS in adult patients. If the new device proves reliable in facilitating awake oral, future patients benefit from an additional tool that allows fast and safe intubation in difficult airway situations.
Looking for future studies?
Notify Me18 year–80 year
All sexes
Observational
Bern, 3010, Switzerland
In the majority of cases, airway management is uncomplicated and a straightforward procedure. Nevertheless, in rare cases complications are associated with notably high rates of serious consequences.
Therefore, assured and reliable intubation is fundamental to safe anesthetic practice.
Various approaches were introduced by the medical device industry to optimize intubation procedure. Nowadays, the gold standard for difficult airway management is awake intubation with a flexible fiberscope. Alternatively, when the flexible fiberscope is unable to facilitate tracheal intubation, rigid stylets may be used. One newly developed rigid video stylet also features a flexible tip (C-MAC VS, Karl Storz AG, 78532 Tuttlingen, Germany). The C-MAC VS is an advancement of the rigid "Bonfils" stylet (Karl Storz, Karl Storz AG, 78532 Tuttlingen, Germany). The distal angular offset of the C-MAC VS, in which the camera and light source are integrated, can be aligned (up to 60°) to the patient's anatomical structures to facilitate intubation.
Although awake intubation is less comfortable for the patient and more time consuming, there are several reasons why this is often performed.
In this research project, the investigators plan a prospective observational study using the C-MAC VS on adult patients with indication for awake oral intubation. Spontaneous ventilation will be maintained until confirmation of tracheal intubation.To ease the placement of the tube (intubation), the investigators will use local anesthesia of the mucosa in the mouth, pharynx and larynx.
The study physician will intubate the trachea of the patient using the C-MAC VS. Another person of the study team will record the primary and secondary outcomes on the Case Report Form.
After intubation, the anesthetist evaluates the intubation. Participants will be followed up for procedure related complications after the intubation and on the 1st post-anesthesia day to evaluate patient intubation comfort (VAS 1: very easy to 10: very hard).
The main purpose of the study is to prove the feasibility of successful awake intubation with the C-MAC VS in adult patients. If the new device proves reliable in facilitating awake oral, future patients benefit from an additional tool that allows fast and safe intubation in difficult airway situations.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
C-MAC VS, Karl Storz AG, 78532 Tuttlingen, Germany It has a flexible tip and a distal angular offset, in which the camera and light sources are integrated. It can be aligned (up to 60°) to the patient's anatomical structures to facilitate intubation.
Time frame: 120 seconds
The intubation success rate at first attempt in less than 120 seconds
Time frame: Device passes patients lips until the device is completely removed out of the tracheal tube and the first end tidal CO2 is shown (the entire process should not pass 120 seconds)
Interim times of airway management (intubation start, first view of vocal cords, device out of the tube - first end tidal CO2)
Time frame: Device passes patients lips until the device is completely removed out of the tracheal tube and the first end tidal CO2 is shown (the entire process should not pass 120 seconds)
The period of time that is needed for the airway management and the respiratory security
Time frame: On the 1st post-procedure day
The investigators will evaluate their comfort during intubation on the 1st post-procedure day on a VAS (visual analogue pain scale) 1-10 (1: very easy, 10: very hard).
Time frame: The first time the device passes patients lips until the respiratory is secured so the device is completely removed out of the tracheal tube and the first end tidal CO2 is shown.
The total number that is needed to secure the airway with intubation
Time frame: During the process of screening, up to 24 hours before the study session starts
The weight of each patient will be presented in kilograms
Time frame: During the process of screening, up to 24 hours before the study session starts
The size of each patient will be presented in meter/centimeter
Time frame: During the process of screening, up to 24 hours before the study session starts
The gender (female or male) will be presented
Time frame: During the process of screening, up to 24 hours before the study session starts
Weight and Height will be combined to report BMI in kg/m2
Time frame: Device passes patients lips until the device is completely removed out of the tracheal tube and the first end tidal CO2 is shown (the entire process should not pass 120 seconds)
The investigators will use the standard non-invasive monitoring of the University Hospital to measure the blood pressure (in millimeters of mercury)
Time frame: Device passes patients lips until the device is completely removed out of the tracheal tube and the first end tidal CO2 is shown (the entire process should not pass 120 seconds)
The investigators will use the standard non-invasive monitoring of the University Hospital to measure the heart rate (beats per minute)
Time frame: Device passes patients lips until the device is completely removed out of the tracheal tube and the first end tidal CO2 is shown (the entire process should not pass 120 seconds)
The investigators will use the standard non-invasive monitoring of the University Hospital to measure the arterial oxygen saturation (SaO2 in percent)
Time frame: Device passes patients lips until the device is completely removed out of the tracheal tube and the first end tidal CO2 is shown (the entire process should not pass 120 seconds)
The anesthetist rates the POGO (Percentage of Glottis Opening), the quality of the vision device and the intubation difficulty on a VAS (visual analogue pain scale) 1-10 (1: very easy, 10: very hard).
Insel Gruppe AG, University Hospital Bern
Other
Awake Intubation in Difficult Airway- a Prospective Observational Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04716218
Intubation;Difficult
Seoul, South Korea
View Trial DetailsNCT03779984
Intubation;Difficult
Dallas, Texas, United States
View Trial DetailsNCT06448377
Airway Management, Intubation;Difficult
Kocaeli, Izmıt, Turkey (Türkiye)
View Trial DetailsNCT04457453
Intubation;Difficult
Suwon, Gyeong-gi Do, South Korea
View Trial Details