Hôpital Saint-Joseph
Marseille, 13008, France
NCT Number: NCT05362656
Interventional, prospective, non-randomized, single-center, non-controlled clinical investigation as part of the premarket clinical evaluation of VX1+ medical device, aiming to verify that VX1+ in bidirectional configuration with auto-tagging function is both ergonomic and reliable for dispersed electrograms detection and automatic tagging on 3D-map in real-time.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Marseille, 13008, France
Ablation of Atrial Fibrillation (AF) and Atrial Tachycardia (AT) is typically performed in predetermined anatomic regions of the left atrium (pulmonary veins isolation) and may be supplemented by a tailored ablation approach in order to identify areas of interest specific to the patient. The VX1+ medical device is intended to assist operators in the manual or automatic real-time annotation of 3D electroanatomical maps of the heart for the presence of multipolar intra-cardiac atrial electrograms exhibiting spatio-temporal dispersion during ablation procedures.
This study will specifically allow to evaluate the peroperative performance of VX1+ automatic tagging function in bi-directional configuration with a compatible 3D mapping system.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Careful biatrial high density dispersion mapping is performed as the first step of the procedure. Operators map each region of both atria carefully by moving the mapping catheter slowly. If VX1+ application detects dispersion regions, the corresponding dipoles location will be automatically tagged on the 3D-map. Accuracy and relevance of dispersion regions should be confirmed by the operator by checking EGMs visually.
Time frame: During procedure
Comparison between the automatically annotated areas with VX1+ and those annotated manually following the operator's visual analysis (true positive, false positive, false negative).
Time frame: During procedure
Comparison between the cardiac cycle length values estimated by VX1+ and the values measured manually by the operator from the electrograms signals (EGM).
Time frame: Through study completion, assessed up to 4 months
Score of the operator's satisfaction and usage feedbacks regarding the ergonomics of VX1 +
Time frame: From the date of hospitalization for the ablation procedure until the date of discharge, up to 1 week
Rate of device deficiencies during the mapping phase, rate of Adverse Events for the hospitalization period and mapping time of dispersion areas with VX1+ device.
Volta Medical
Industry
Preliminary Evaluation of the Artificial Intelligence Software VX1+ for the Detection and Automatic Tagging on 3D Mapping of Spatio-temporal Dispersion Areas During Atrial Fibrillation or Atrial Tachycardia Ablation Procedures.
Acronym: AMPERE
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05014802
Arrhythmias, Cardiac, Atrial Arrhythmia
Covington, Louisiana, United States
View Trial DetailsNCT05883631
Arrhythmia, Arrhythmias, Cardiac
Birmingham, Alabama, United States
View Trial DetailsNCT07580937
Arrhythmias, Cardiac, Atrial Arrhythmia
Chicago, Illinois, United States
View Trial DetailsNCT06223789
Arrhythmias, Cardiac, Atrial Arrhythmia
Birmingham, Alabama, United States
View Trial Details