Pulsed Field Ablation
DevicePulsed field ablation using the Volt PFA System
NCT Number: NCT06223789
This clinical investigation is intended to demonstrate safety and effectiveness of the Volt™ Pulsed Field Ablation (PFA) Catheter Sensor Enabled™, the Volt™ PFA Generator, Agilis™ NxT Steerable Introducer Dual-Reach™, and EnSite™ X EP System EnSite™ Pulsed Field Ablation Module (for simplicity of reference this device collection will hereafter be referred to as the Volt™ PFA system) for the treatment of symptomatic, recurrent, drug-refractory paroxysmal and persistent atrial fibrillation.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Royal Adelaide Hospital, Adelaide, Australia
This is a pre-market, prospective, non-randomized, multicenter clinical study to demonstrate safety and effectiveness for the treatment of symptomatic, recurrent, drug-refractory paroxysmal atrial fibrillation (PAF) and persistent atrial fibrillation (PersAF).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Paroxysmal:
Persistent: Continuous AF sustained beyond 7 days and less than 1 year that is documented by
NOTE: Documented evidence of the AF episode must either be continuous AF on a 12-lead ECG or include at least 30 seconds of AF from another ECG device.
Exclusion criteria
Pulsed field ablation using the Volt PFA System
Time frame: 7-days
Serious adverse events are defined as:
Time frame: 12-months
Rate of freedom from documented (symptomatic or asymptomatic) AF/AFL/AT episodes of >30 seconds duration that are documented by protocol-specified 12-lead ECG, trans-telephonic monitoring (TTM) or Holter monitor after the index ablation procedure through 12 months of follow-up (after a 90-day blanking period following the index ablation procedure).
Time frame: 12-months
Rate of freedom from documented symptomatic AF/AFL/AT episodes of >30 seconds duration that are documented by protocol-specified 12-lead ECG, trans-telephonic monitoring (TTM) or Holter monitor after the index ablation procedure through 12 months of follow-up (after a 90-day blanking period following the index ablation procedure).
Time frame: 12-months
Rate of freedom from documented (symptomatic or asymptomatic) AF/AFL/AT episodes of >30 seconds duration that are documented by protocol-specified 12-lead ECG, trans-telephonic monitoring (TTM) or Holter monitor after the index ablation procedure through 12 months of follow-up off all Class I and III AADs (after a 90-day blanking period following the index ablation procedure)
Abbott Medical Devices
Industry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06106594
Arrhythmias, Cardiac, Atrial Arrhythmia
Chermside, Queensl, Australia
View Trial DetailsNCT07181590
Arrhythmias, Cardiac, Atrial Arrhythmia
Linz, Austria
View Trial DetailsNCT05411614
Arrhythmias, Cardiac, Atrial Arrhythmia
Chertsey, United Kingdom
View Trial DetailsNCT07580937
Arrhythmias, Cardiac, Atrial Arrhythmia
Chicago, Illinois, United States
View Trial Details