Augmented Infant Resuscitator (AIR)
DeviceDevice provides visual feedback related to air leak, obstruction, hyperventilation, hypoventilation, and harsh breaths
Other names: AIR device with feedback
NCT Number: NCT04820504
Augmented Infant Resuscitator (AIR) is an inexpensive add-on, compatible with nearly every existing bag-valve mask and many types of ventilation equipment. AIR monitors ventilation quality and provides real-time objective feedback and actionable cues to clinicians to both shorten training times and improve resuscitation quality, adoption, retention, and confidence.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Longitudinal, randomized control trial that examined the effectiveness of AIR among 270 participants, with 1,080 recorded ventilation scenarios, and across 20 sites in Uganda and the U.S. Birth attendants - including a mix of midwives, nurses, respiratory therapists, pediatricians, and neonatologists - with recent HBB and/or NRP training were recruited to participate in this randomized control trial. Participants ventilated training mannequins for a fixed duration of time. Participants were randomized to receive visual feedback from AIR (intervention) or have the AIR feedback covered (control). They were then requested to administer effective ventilation and verbally assess the mannequin condition. All mannequins appeared to be identical, but each session's mannequin was randomly selected with an upper airway that was normal, partially leaking, or partially obstructed.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Device provides visual feedback related to air leak, obstruction, hyperventilation, hypoventilation, and harsh breaths
Other names: AIR device with feedback
Device provides no visual feedback to clinician but records data on ventilation effectiveness
Time frame: 2 minutes
Duration of effective bag-mask ventilation by clinician during a 2-minute trial. [This will be a cumulative duration of the two minutes. This is measured internally from the AIR device. "Effective ventilation" is defined as having all three of the following conditions simultaneously: (1) Correct rate (30-60 breaths per minute); (2) Absence of significant leak (compliance >4.0mL/cm H2O); and (3) Absence of a significant airway blockage (defined as compliance <0.10 mL/cm H2O or resistance >90 cmH2O/L/s). These measurements are determined by sensors in the AIR device for both arms of the study. Their accuracy for manikin use was determined to be 100% in the following trial: Bennett el al. Anesth Analgesia. 2018 Mar;126(3):947-955. doi: 10.1213/ANE.0000000000002432.]
Time frame: 2 minutes
How long it takes for clinician to achieve effective ventilation during 2-minute trial. [This is time from when the mask first touches the face of the manikin until all three icons are green. This is measured by a Research Assistant using a stop-watch. Again, "Effective ventilation" is defined as having all three of the following conditions simultaneously and is indicated to the RA by all three icons on the AIR device turning green: (1) Correct rate (30-60 breaths per minute); (2) Absence of significant leak (compliance >4.0mL/cm H2O); and (3) Absence of a significant airway blockage (defined as compliance <0.10 mL/cm H2O or resistance >90 cmH2O/L/s). These measurements are determined by sensors in the AIR device for both arms of the study. Their accuracy for manikin use was determined to be 100% in the following trial: Bennett et al. Anesth Analgesia 2018 Mar;126(3):947-955. doi: 10.1213/ANE.0000000000002432.]
Time frame: 2 minutes
Ability of clinician to correctly assess three different manikin airway issues: normal, air leak, or obstruction. [Manikin "conditions" are blinded to the participants and were either normal (as supplied by the manufacturer, had a "leak" insert (introduced compliance >4mL/cm H2O), or had an "obstruction" insert (introduced a reduction in compliance <0.10mL/cm H2O and resistance >90 cm H2O/L/s. As per the parameters in the following paper: Bennett et al. Anesth Analgesia. 2018 Mar;126(3):947-955. doi: 10.1213/ANE.0000000000002432.]
Massachusetts General Hospital
Other
Augmented Infant Resuscitator (AIR): Transitioning a Novel Behavior Change Innovation to Drive Newborn Ventilation Skills Enhancement
Acronym: AIR
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05349175
Asphyxia Neonatorum, Birth Asphyxia
Boston, Massachusetts, United States
View Trial DetailsNCT07681960
Airway Management, Asphyxia Neonatorum
Kahramanmaraş, Turkey (Türkiye)
View Trial DetailsNCT03278847
Asphyxia Neonatorum, Body Temperature Changes
London, United Kingdom
View Trial DetailsNCT02572427
Asphyxia Neonatorum, Congenital, Hereditary, and Neonatal Diseases and Abnormalities
View Trial Details