Skip to main content
OpenTrials
Recruiting

NCT Number: NCT07510893

Augmented Feedback Effects on Shoulder Rotator Performance

The existing literature demonstrates that motor learning strategies are effective in enhancing sports performance. One of these strategies, augmented feedback, is widely used in athletic training to help athletes achieve their goals more effectively, support the learning process, and motivate improvements in performance. Although studies in the literature have demonstrated the positive effects of augmented feedback provided during training on performance, no study has been found that examines the acute effects of such feedback on peak force and rate of force development during isometric training of the shoulder internal and external rotator muscles. The aim of this study is to investigate the acute effects of outcome feedback on isometric peak force and rate of force development during isometric training of the shoulder internal and external rotator muscles, as well as the short-term retention of these effects. It is expected that augmented feedback on isometric peak force and rate of force development, provided during isometric training of the shoulder internal and external rotator muscles, will have both acute and short-term retention effects on strength parameters. Healthy and physically active individuals will participate in isometric strength training targeting the dominant side shoulder internal and external rotator muscles across two separate sessions. Within a randomized crossover design, all participants will perform the isometric training program under two different conditions: with augmented feedback and without augmented feedback. The order of the conditions will be determined using a computer-based randomization program.To minimize potential learning effects, a washout period of 5-7 days will be provided between the two training conditions. Testing and training protocols will be conducted using an isometric dynamometer (ForceFrame, VALD Performance, Australia). The reported intraclass correlation coefficients (ICC) of the ForceFrame dynamometer for shoulder strength measurements range between 0.85 and 0.91, indicating good to excellent test-retest reliability. All testing and training procedures will be performed in accordance with the standard testing positions recommended by the manufacturer.

Recruiting

Interested in participating?

Request Info

Key information

Age range

18 year–30 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Hacettepe University, Faculty of Physical Therapy and Rehabilitation,

Ankara, Sıhhıye, 06100, Turkey (Türkiye)

Location status: Recruiting

Location contact

Elif Turgut, PhD, PT

CONTACT

[email protected]

+905442645600

About this study

All participants will complete a standardized warm-up protocol of approximately 10 minutes prior to the testing sessions. The warm-up will begin with arm circles to promote active mobilization of the shoulder joint. This will be followed by one set of 10 repetitions of shoulder internal and external rotation exercises performed at 90° of shoulder abduction and 90° of elbow flexion using a resistance band providing submaximal resistance. Following the warm-up, a familiarization session will be conducted to increase participants' familiarity with the ForceFrame device used in the testing and training sessions. During this session, participants will perform five repetitions of isometric contractions, each lasting 5 seconds, at a self-selected submaximal effort level. The familiarization session is intended to ensure participants' adaptation to the testing procedure, learning of the correct movement sequence, and execution of the exercise with proper technique. Following completion of the warm-up protocol, isometric muscle strength and rate of force development of the dominant shoulder internal and external rotator muscles will be assessed. All measurements will be performed using an isometric dynamometer (ForceFrame). During testing, participants will be positioned in a supine position with the knees flexed and feet flat on the ground, while the non-tested arm will be placed across the chest.

The tested shoulder will be positioned at 90° of abduction and the elbow at 90° of flexion, with the hand placed at a comfortable height appropriate for pushing against the sensors. The testing protocol will consist of three repetitions of maximal isometric contractions, each lasting 5 seconds, with 20 seconds of rest between repetitions. Maximum force and rate of force development values will be recorded during each trial. Throughout testing, participants will be instructed to maintain the standardized position and keep their arms stable. Prior to each test, standardized verbal instructions will be provided, instructing participants to perform the contractions "by producing maximal force as quickly as possible." The test protocol will be administered at three time points: before the isometric training (pre-test), immediately after the training protocol (post-test), and 15 minutes after training to assess immediate retention (immediate retention test).

Following the pre-test, participants will perform the isometric training protocol targeting the shoulder internal and external rotator muscles. The training protocol will also be conducted using the ForceFrame device. During training, participants will be positioned identically to the testing protocol, in a supine position with the knees flexed and feet flat on the ground, while the non-tested arm will be placed across the chest. The tested shoulder will be positioned at 90° of abduction and the elbow at 90° of flexion. The training protocol will consist of one set of three repetitions, each involving a 5-second isometric contraction, with 20 seconds of rest between repetitions. Throughout the training, participants will be instructed to maintain the standardized position and keep their arms stable. Standardized verbal instructions will be provided to all participants, instructing them to perform the isometric contractions "by producing maximal force as quickly as possible."

Knowledge of results will be provided between repetitions during the training session. Following each repetition, participants will receive immediate quantitative feedback regarding their maximum force (peak force) and rate of force development. The feedback will be delivered by the same physiotherapist to all participants, using a clear and emphatic tone, slightly louder than normal conversational volume to ensure it is distinguishable from background noise.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Healthy individuals aged between 18 and 30 years,
  • Body Mass Index (BMI) below 30 kg/m²,
  • An activity level of 5 or higher according to the Tegner Activity Scale,
  • Full active range of motion (ROM) in shoulder flexion, abduction, internal, and external rotation.

Exclusion criteria

  • Resence of current pain complaints,
  • Provocation of symptoms during at least one of the specific shoulder clinical tests (Neer Test, Hawkins-Kennedy Test, Jobe Test, Resisted External Rotation Test, and Apprehension Test),
  • History of any upper extremity injury, pain, or surgical intervention within the past 12 months,
  • Presence or history of hypertension, cardiovascular diseases, peripheral vascular diseases, deep vein thrombosis, neurological disorders, systemic inflammation, diabetes, cancer, or obesity,
  • Unwillingness to participate in the study.

Treatment and study plan

Augmented Feedback

Other

Augmented feedback is a term used to describe information about the performance of a skill provided from an external source. When this information is presented quantitatively, it is referred to as Knowledge of results (e.g., movement velocity, jump height, or peak force). Knowledge of results, which is a critical component of performance improvement, is delivered to athletes through professional coaching staff as well as advanced technological applications. Accordingly, research in this area has focused on the pivotal role of real-time data flow and feedback in optimizing performance.

Primary outcomes

  1. Peak Force

    Time frame: Within the same intervention day: Baseline, immediately post-intervention, and 15 minutes post-intervention

    Peak force refers to the maximum force generated by the shoulder internal or external rotator muscles during a single maximal isometric contraction.

  2. Rate of Force Development

    Time frame: Within the same intervention day: Baseline, immediately post-intervention, and 15 minutes post-intervention

    Rate of Force Development efers to the speed at which force is generated by the shoulder internal or external rotator muscles during a maximal isometric contraction.

Study contacts

Contact information is provided by the study sponsor or research team.

Elif Turgut, PhD, PT

CONTACT

[email protected]

+905442645600

Sponsors and collaborators

Lead sponsor

Elif Turgut

Other

Collaborators

  • Hacettepe University

Registry information

Official study title

Immediate and Retention Effects of Augmented Feedback on Isometric Peak Force and Rate of Force Development of Shoulder Rotators

Important dates

Study start
2026
Primary completion
2026
Study completion
2026
First posted
Apr 6, 2026
Registry last updated
Apr 6, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.